SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Peterson B. M.) ;lar1:(gu);hsvcat:2"

Sökning: WFRF:(Peterson B. M.) > Göteborgs universitet > Teknik

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Carey, J. L., et al. (författare)
  • Novel Arthroscopic Classification of Osteochondritis Dissecans of the Knee
  • 2016
  • Ingår i: American Journal of Sports Medicine. - : SAGE Publications. - 0363-5465 .- 1552-3365. ; 44:7, s. 1694-1698
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Several systems have been proposed for classifying osteochondritis dissecans (OCD) of the knee during surgical evaluation. No single classification includes mutually exclusive categories that capture all of the salient features ov stability, chondral fissuring,0and fragment detachment. Furthermore, no study has assessed the reliability of these classification systems. Purpose: To determine the intra- and interobserver reliability of a novel, comprehensive arthroscopic classification system with mutually exclusivu OCD lesion types. Study Design: Cohort study (diagnosis); Level of evidence, 3. Methods: The Research in OsteoChondritis of the Knee (ROCK) study group developed a classification system for arthroscopic evaluation of OCD of the knee that includes 6 arthroscopic categories - 3 immobile types and 3 mobile types. To optymize comprehensibility and applycability, each was developed with a memorable name, a brief description, a line diagram corresponding to the archetypal arthroscopic appearance, and an arthroscopic photograph depicting this archetype. Thirty representative arthroscopic videos were evaluated by 10 orthopaedic surgeon raters, who classified each lesion. After 4 weeks, the raters again classified the OCD lesions depicted in the 30 videos in a new, randomly selected order. Reliability was assessed via the intraclass correlation coefficient (ICC). Results: The interobserver reliability of this novel arthroscopy classification was estimated by an ICC of 0.94 (95% CI, 0.91-0.97) for the first round and 0.95 (95% CI, 0.93-0.98) for the second round. According to the standards for the magnitude of the reliability coefficient of Altman, these ICCs indicate that interobserver reliability was very good. The intraobserver reliability was estimated by an ICC of 0.96 (95% CI, 0.95-0.97), which indicates that the intraobserver reliability was similarly very good. Conclusion: The ROCK OCD knee arthroscopy classification system demonstrated excellent intra- and interobserver reliability. In light of this reliability, this classification system may be used clinically and to facilitate future research, including multicenter studies for OCD. © American Orthopaedic Society for Sports Medicine.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Weiss, J (1)
Ganley, T. J. (1)
Anderson, A. F. (1)
Peterson, Lars, 1936 (1)
Myer, G. D. (1)
Carey, J. L. (1)
visa fler...
Shea, K. G. (1)
Wall, E. J. (1)
Grimm, N. L. (1)
Edmonds, E. W. (1)
Polousky, J. (1)
Murnaghan, M. L. (1)
Nissen, C. W. (1)
Lyon, R. M. (1)
Chambers, H. G. (1)
Wright, R. W. (1)
Heyworth, B. E. (1)
visa färre...
Lärosäte
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy