SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:DiVA.org:kth-298758" "

Sökning: id:"swepub:oai:DiVA.org:kth-298758"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Damiati, Samar, et al. (författare)
  • Flex Printed Circuit Board Implemented Grapene-Based DNA Sensor for Detection of SARS-CoV-2
  • 2021
  • Ingår i: IEEE Sensors Journal. - : Institute of Electrical and Electronics Engineers (IEEE). - 1530-437X .- 1558-1748. ; 21:12, s. 13060-13067
  • Tidskriftsartikel (refereegranskat)abstract
    • Since the COVID-19 outbreak was declared a pandemic by the World Health Organization (WHO) in March 2020, ongoing efforts have been made to develop sensitive diagnostic platforms. Detection of viral RNA provides the highest sensitivity and specificity for detection of early and asymptomatic infections. Thus, this work aimed at developing a label-free genosensor composed of graphene as a working electrode that could be embedded into a flex printed circuit board (FPCB) for the rapid, sensitive, amplification-free and label-free detection of SARS-CoV-2. To facilitate liquid handling and ease of use, the developed biosensor was embedded with a user-friendly reservoir chamber. As a proof-of-concept, detection of a synthetic DNA strand matching the sequence of ORF1ab was performed as a two-step strategy involving the immobilization of a biotinylated complementary sequence on a streptavidin-modified surface, followed by hybridization with the target sequence recorded by the differential pulse voltammetric (DPV) technique in the presence of a ferro/ferricyanide redox couple. The effective design of the sensing platform improved its selectivity and sensitivity and allowed DNA quantification ranging from 100 fg/mL to 1 mu g/mL. Combining the electrochemical technique with FPCB enabled rapid detection of the target sequence using a small volume of the sample (5-20 mu L). We achieved a limit-of-detection of 100 fg/mL, whereas the predicted value was similar to 33 fg/mL, equivalent to approximately 5 x 10(5) copies/mL and comparable to sensitivities provided by isothermal nucleic acid amplification tests. We believe that the developed approach proves the ability of an FPCB-implemented DNA sensor to act as a potentially simpler and more affordable diagnostic assay for viral infections in Point-Of-Care (POC) applications.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Russom, Aman, Prof. ... (1)
Akhtar, Ahmad Saleem (1)
Soares, Ruben R. G. (1)
Pinto, Ines Fernande ... (1)
Damiati, Samar (1)
Sopstad, Sindre (1)
visa fler...
Peacock, Martin (1)
visa färre...
Lärosäte
Kungliga Tekniska Högskolan (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Teknik (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy