SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:DiVA.org:oru-101793" "

Sökning: id:"swepub:oai:DiVA.org:oru-101793"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Yang, Ya, et al. (författare)
  • Human exposure to phthalate esters via ingestion of municipal drinking water from automatic water purifiers : levels, sources, and risks
  • 2022
  • Ingår i: Environmental Science. - : Royal Society of Chemistry. - 2053-1400 .- 2053-1419. ; 8:12, s. 2843-2855
  • Tidskriftsartikel (refereegranskat)abstract
    • The presence of organic pollutants in drinking water is an environmental problem threatening public health. Water purifiers are commonly recognized as effective purification equipment for drinking water and are thus prevalent in the market, so there is a need to assess their true effects on drinking water. In this study, we have analyzed the distribution, potential sources, and health risks of phthalate esters (PAEs) in tap as well as purified water. 7 out of 22 target PAEs have been detected in a total of 75 drinking water samples, including tap water (TW), water vending machines (WVMs), and water boiling machines (WBMs). The total concentrations of 22 PAEs are N.D. to 447 ng L-1 in TW samples, 25.7 to 1.10 x 10(3) ng L-1 in WBM water, and N.D. to 841 ng L-1 in WVM water. The concentrations of PAEs in most WVM and WBM samples were comparable or slightly higher than those in TW samples. Meanwhile, the sigma PAE concentrations in the nearshore of the Yangtze Estuary area (northern and southern areas) were slightly higher than those from offshore areas (Pudong: PD, Fengxian and Minhang: FM), which may be attributed to the source water. Combining the results of principal component analysis and correlation analysis, certain PAEs, e.g., diisobutyl phthalate (DIBP), dibuthyl phthalate (DBP), and di(2-ethylhexyl) phthalate (DEHP), were more polluting than diethyl phthalate (DEP) and di-methyl phthalate (DMP) in WVM water than those in TW samples. This work suggests that the application of water purifiers may not remove certain PAEs efficiently from drinking water. In addition, the estimated daily intakes (EDIs) of sigma PAE via drinking water from automatic water purifiers were 2-3 times those from tap water under a high-exposure scenario, but all EDIs are well below current health regulatory guidelines for PAEs. This survey indicates that water purifiers made nearly no decrease to the PAE concentrations and possibly have negative effects on the quality of drinking water.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Zhu, Zhiliang (1)
Bergman, Åke, 1950- (1)
Qiu, Yanling (1)
Zhao, Jianfu (1)
Huang, Qinghui (1)
Yang, Ya (1)
visa fler...
Song, Linlin (1)
visa färre...
Lärosäte
Stockholms universitet (1)
Örebro universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy