SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "id:"swepub:oai:DiVA.org:uu-285830" "

Search: id:"swepub:oai:DiVA.org:uu-285830"

  • Result 1-1 of 1
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Xie, Ling, et al. (author)
  • 3D electron tomography analysis of silicon nanoparticles in SiC matrices by quantitative determination of EELS plasmon intensities
  • 2014
  • Conference paper (peer-reviewed)abstract
    • Silicon nanoparticles (NPs) embedded in insulating or semiconducting matrices has attracted much interest for the third generation of photovoltaics, “all-Si” tandem solar cells. This study is to show how silicon NPs are distributed in 3D on a silicon carbide thin film using the electron tomography technique in the transmission electron microscopy (TEM). [2]We first have assessed Si NPs distributions in such SiCx sample with a low degree of crystalline using bright field (BF) TEM tomography (figure 1) and found an average nearest neighbor spacing of two NPs of about 12nm. For more crystalline NPs, the projection requirement is no more fulfilled and only those Si NPs that are both crystalline and oriented to a Bragg reflection are detectable. [3] Therefore, in this case, conventional BF TEM signal is unsuitable for electron tomography and we applied spectrum imaging (SI) techniques: EELS SI imaging and EFTEM SI imaging. Since Si and SiCx have different plasmon energies, [4] we can extract Si plasmon and SiCx plasmon images from the spectrum images. We observed that only a proper fit of the plasmon spectrum with subsequent extraction of Si and SiCx plasmon images results in the correct Si ad SiCx distribution (figures 2 and 3), whereas just EFTEM images taken from windows around the Si and the SiC plasmon energy resulted in overlaps in the image. For both, STEM and EFTEM SI signals, in figure 2 and 3, we are able to detect the entire population of NPs. In figure 3, the stripes like contrast inside of crystalline NPs shown in the BF TEM image persist in plasmon images. This is due to parallel beam illumination in EFTEM SI mode thus making the STEM SI imaging more suitable for tomography of these NPs. In Figure 2, for STEM SI, the contrast evolution during the tilting is thickness dependent, thicker part of the sample gives stronger contrast in the extracted plasmon images, and this nonlinear thickness effect can be corrected by introducing attenuation coefficient. [5]In summary, to study the 3D distribution of Si NPs in SiCx matrix, we compared three signals from BF TEM, STEM and EFTEM SI signals. In order to overcome the non-linearity of contrast change during the tilting process, STEM-SI signal in combination with quantitative treatment of the plasmon spectra shows clear Si NP contrasts and overcomes limits set by the projection requirement.[1] S. Perraud et al., Phys. Status Solidi A, 1–9 (2012).[2] J. Frank, Electron Tomography: Three Dimensional Imaging with the Transmission ElectronMicroscope, Plenum, New York, London, 1992.[3] P. A. Midgley et al., Ultramicroscopy 96 (2003) 413.[4] R.F. Egerton, Electron Energy-Loss Spectroscopy in the Electron Microscope, 420, 2011.[5] W. Van den Broek et al. Ultramicroscopy 116 (2012) 8–12
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-1 of 1
Type of publication
conference paper (1)
Type of content
peer-reviewed (1)
Author/Editor
Leifer, Klaus (1)
van Swaaij, Rene A C ... (1)
Zeman, Miro (1)
Xie, Ling (1)
Karol, Jarolimek (1)
University
Uppsala University (1)
Language
English (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view