SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:DiVA.org:uu-303286" "

Sökning: id:"swepub:oai:DiVA.org:uu-303286"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Germovsek, Eva, et al. (författare)
  • Development and Evaluation of a Gentamicin Pharmacokinetic Model That Facilitates Opportunistic Gentamicin Therapeutic Drug Monitoring in Neonates and Infants
  • 2016
  • Ingår i: Antimicrobial Agents and Chemotherapy. - 0066-4804 .- 1098-6596. ; 60:8, s. 4869-4877
  • Tidskriftsartikel (refereegranskat)abstract
    • Trough gentamicin therapeutic drug monitoring (TDM) is time-consuming, disruptive to neonatal clinical care, and a patient safety issue. Bayesian models could allow TDM to be performed opportunistically at the time of routine blood tests. This study aimed to develop and prospectively evaluate a new gentamicin model and a novel Bayesian computer tool (neoGent) for TDM use in neonatal intensive care. We also evaluated model performance for predicting peak concentrations and the area under the concentration-time curve from time 0 h to time t h (AUC(0-t)). A pharmacokinetic meta-analysis was performed on pooled data from three studies (1,325 concentrations from 205 patients). A 3-compartment model was used with the following covariates: allometric weight scaling, postmenstrual and postnatal age, and serum creatinine concentration. Final parameter estimates (standard errors) were as follows: clearance, 6.2 (0.3) liters/h/70 kg of body weight; central volume (V), 26.5 (0.6) liters/70 kg; intercompartmental disposition (Q), 2.2 (0.3) liters/h/70 kg; peripheral volume V2, 21.2 (1.5) liters/70 kg; intercompartmental disposition (Q2), 0.3 (0.05) liters/h/70 kg; peripheral volume V3, 148 (52.0) liters/70 kg. The model's ability to predict trough concentrations from an opportunistic sample was evaluated in a prospective observational cohort study that included data from 163 patients and 483 concentrations collected in five hospitals. Unbiased trough predictions were obtained; the median (95% confidence interval [CI]) prediction error was 0.0004 (-1.07, 0.84) mg/liter. Results also showed that peaks and AUC(0-t) values could be predicted (from one randomly selected sample) with little bias but relative imprecision, with median (95% CI) prediction errors being 0.16 (-4.76, 5.01) mg/liter and 10.8 (-24.9, 62.2) mg center dot h/liter, respectively. neoGent was implemented in R/NONMEM and in the freely available TDMx software.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Standing, Joseph F. (1)
Nielsen, Elisabet I (1)
Klein, Nigel (1)
Germovsek, Eva (1)
Kent, Alison (1)
Metsvaht, Tuuli (1)
visa fler...
Lutsar, Irja (1)
Turner, Mark A. (1)
Sharland, Mike (1)
Heath, Paul T. (1)
visa färre...
Lärosäte
Uppsala universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy