SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:lup.lub.lu.se:26eb0f43-d249-4ab3-9196-0bb324bb6426" "

Sökning: id:"swepub:oai:lup.lub.lu.se:26eb0f43-d249-4ab3-9196-0bb324bb6426"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Reitan, Öyvind, et al. (författare)
  • Initial tests with a new cardiac assist device
  • 1999
  • Ingår i: ASAIO Journal. - 1538-943X. ; 45:4, s. 317-321
  • Tidskriftsartikel (refereegranskat)abstract
    • Before, during, and after cardiac intervention, there is occasionally a need for circulatory support because of hemodynamic deterioration. For this purpose, a new minimally invasive cardiac assist device has been developed, and an early prototype has been studied in a bench test and in three pigs. The pump is a catheter system with a distal motor driven propeller (0-15,000 rpm) surrounded by a cage. The catheter was first tested in a tube in a water bath, where efficiency with respect to pressure generation and flow properties was measured. In the pig experiments, the pump was placed in the descending part of the aorta via a graft, and hemodynamic effects were recorded with three different propellers. The bench tests showed a velocity dependent pressure generation in the tube to the second power of the rpm, and 30 cm of water (> 22 mm Hg) could easily be achieved with all propellers. A pressure dependent flow in the tube was observed, with maximum flows of 20 L at 12,000 rpm and 27 L at 15,000 rpm. In the animal experiments, there was a velocity dependent mean pressure difference across the propeller, with up to 48 mm of mercury for the biggest propeller. An increase in cardiac output in all of the pigs was observed as well as a drop in pressure in the proximal part of the aorta. This study demonstrates the efficiency of this new device in vitro and in vivo. Hemodynamic changes are pronounced and are related to the speed and size of the propeller.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Steen, Stig (1)
Öhlin, Hans (1)
Emanuelsson, H (1)
Peterzen, B (1)
Reitan, Öyvind (1)
Granfeldt, H (1)
Lärosäte
Lunds universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy