SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "id:"swepub:oai:lup.lub.lu.se:f487b8e2-f1c4-4557-9cd8-c686210b80cd" "

Sökning: id:"swepub:oai:lup.lub.lu.se:f487b8e2-f1c4-4557-9cd8-c686210b80cd"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Sommar, Johan Nilsson, et al. (författare)
  • Investigation of lead concentrations in whole blood, plasma and urine as biomarkers for biological monitoring of lead exposure
  • 2014
  • Ingår i: Journal of Exposure Science & Environmental Epidemiology. - : Springer Science and Business Media LLC. - 1559-064X .- 1559-0631. ; 24:1, s. 51-57
  • Tidskriftsartikel (refereegranskat)abstract
    • Lead in blood is a major concept in biomonitoring of exposure but investigations of its alternatives are scarce. The aim of the study was to describe different lead biomarkers' variances, day-to-day and between individuals, estimating their fraction of the total variance. Repeated sampling of whole blood, plasma and urine were conducted for 48 lead-exposed men and 20 individuals under normal environmental lead exposure, in total 603 measurements. For lead workers, the fraction of the total variance attributed to differences between individuals was 91% for whole-blood lead (geometric mean 227 mg/l; geometric standard deviation (GSD): 1.55 mg/l); plasma 78% (0.57 mg/l; GSD: 1.84 mg/l); density-adjusted urine 82%; and unadjusted urine 75% (23.7 mg/l; GSD: 2.48 mg/l). For the individuals under normal lead exposure, the corresponding fractions were 95% of the total variance for whole blood (20.7 mg/l; GSD: 8.6 mg/l), 15% for plasma (0.09 mg/l; GSD: 0.04 mg/l), 87% for creatinine-adjusted urine and 34% for unadjusted (10.8 mg/l; GSD: 6.7 mg/l). Lead concentration in whole blood is the biomarker with the best ability to discriminate between individuals with different mean concentration. Urinary and plasma lead also performed acceptably in lead workers, but at low exposures plasma lead was too imprecise. Urinary adjustments appear not to increase the between-individual fraction of the total variance among lead workers but among those with normal lead exposure.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Hedmer, Maria (1)
Bergdahl, Ingvar A. (1)
Nilsson, Leif (1)
Lundh, Thomas (1)
Skerfving, Staffan (1)
Sommar, Johan Nilsso ... (1)
Lärosäte
Umeå universitet (1)
Lunds universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy