SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "id:"swepub:oai:prod.swepub.kib.ki.se:139280628" "

Search: id:"swepub:oai:prod.swepub.kib.ki.se:139280628"

  • Result 1-1 of 1
Sort/group result
   
EnumerationReferenceCoverFind
1.
  • Brouwer, PA, et al. (author)
  • Thrombectomy using the EmboTrap device: core laboratory-assessed results in 201 consecutive patients in a real-world setting
  • 2018
  • In: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 10:10, s. 964-
  • Journal article (peer-reviewed)abstract
    • We studied patients treated with the EmboTrap revascularization device in a prospective registry which is core laboratory evaluated by physicians from external centers. The goal was to determine how the EmboTrap would perform under the everyday conditions of a high-volume stroke center.MethodsWe examined all patients with acute stroke treated with the Embotrap device from October 2013 to March 2017 in our center. Imaging parameters and times were adjudicated by core laboratory personnel blinded to clinical information, treating physician, and clinical outcomes. Clinical evaluation was performed by independent neurologists and entered in a national registry. Evaluated endpoints were: successful revascularization (modified Thrombolysis in Cerebral Infarction (mTICI) 2b–3) and good clinical outcomes at 3 months (modified Rankin Scale (mRS) 0–2).Results201 consecutive patients with a median NIH Stroke Scale (NIHSS) score of 15 (range 2–30) were included. 170 patients (84.6%) achieved mTICI 2b–3 reperfusion. The median number of attempts was 2 (range 1–10) with 52.8% of the population achieving good functional outcomes (mRS 0–2) at 3 months. On univariate analysis, good functional outcome was associated with the number of attempts, puncture-to-reperfusion time, anterior circulation occlusion, and NIHSS score. On multivariate analysis, pre-treatment NIHSS (OR 0.845 per point, 95% CI 0.793 to 0.908, P<0.001) and puncture-to-reperfusion time (OR 0.9952 per min, 95% CI 0.9914 to 0.9975, P=0.023) were associated with good functional outcomes at 3 months.ConclusionThe Embotrap device has a high rate of successful reperfusion. Our core laboratory-audited single-center experience suggests the technical feasibility and safety of the Embotrap for first-line use in a real-world setting.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 1-1 of 1
Type of publication
journal article (1)
Type of content
peer-reviewed (1)
Author/Editor
Andersson, T. (1)
Soderman, M (1)
Holmin, S. (1)
Bhogal, P (1)
Yeo, LLL (1)
Ohlsson, M (1)
show more...
Holmberg, A (1)
Brouwer, PA (1)
Gontu, VK (1)
Kolloch, J (1)
KuntzeSoderqvist, A (1)
Anastasios, M (1)
show less...
University
Karolinska Institutet (1)
Language
English (1)
Year

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view