SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "onr:"swepub:oai:DiVA.org:liu-171967" "

Sökning: onr:"swepub:oai:DiVA.org:liu-171967"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Baubeta Fridh, Erik, et al. (författare)
  • Comparison of Magnetic Resonance Angiography and Digital Subtraction Angiography for the Assessment of Infrapopliteal Arterial Occlusive Lesions, Based on the TASC II Classification Criteria
  • 2020
  • Ingår i: Diagnostics (Basel). - : MDPI. - 2075-4418. ; 10:11
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper aimed to study the agreement and repeatability, both intra- and interobserver, of infrapopliteal lesion assessment with magnetic resonance angiography (MRA), using the TransAtlantic Inter-Society Consensus (TASC) II criteria, with perioperative digital subtraction angiography (DSA) as a reference. Sixty-eight patients with an MRA preceding an endovascular infrapopliteal revascularization were included. Preoperative MRAs and perioperative DSAs were evaluated in random order by three independent observers using the TASC II classification. The results were analyzed using visual grading characteristics (VGC) analysis and Krippendorffs alpha. No systematic difference was found between modalities: area under the VGC curve (AUC(VGC)) = 0.48 (p = 0.58) or intraobserver; AUC(VGC) for Observer 1 and 2 respectively, 0.49 (p = 0.85) and 0.53 (p = 0.52) for MRA compared with 0.54 (p = 0.30) and 0.49 (p = 0.81) for DSA. Interobserver differences were seen: AUC(VGC) of 0.63 (p < 0.01) for DSA and 0.80 (p < 0.01) for MRA. These results were confirmed using Krippendorffs alpha for the three observers showing 0.13 (95% confidence interval (CI) -0.07-0.31) for MRA and 0.39 (95% CI 0.23-0.53) for DSA. Poor interobserver agreement was also found in the choice of a target vessel on preoperative MRA: Krippendorffs alpha = 0.19 (95% CI 0.01-0.36). In conclusion, infrapopliteal lesions can be reliably determined on preoperative MRA, but interobserver variability regarding the choice of a target vessel is a major concern that appears to affect the overall TASC II grade.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy