SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "onr:"swepub:oai:lup.lub.lu.se:3b8f2191-89fc-4649-9078-715d4a28afa4" "

Sökning: onr:"swepub:oai:lup.lub.lu.se:3b8f2191-89fc-4649-9078-715d4a28afa4"

  • Resultat 1-1 av 1
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Lempart, Michael, et al. (författare)
  • Deep learning-based classification of organs at risk and delineation guideline in pelvic cancer radiation therapy
  • 2023
  • Ingår i: Journal of Applied Clinical Medical Physics. - 1526-9914. ; 24:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Deep learning (DL) models for radiation therapy (RT) image segmentation require accurately annotated training data. Multiple organ delineation guidelines exist; however, information on the used guideline is not provided with the delineation. Extraction of training data with coherent guidelines can therefore be challenging. We present a supervised classification method for pelvis structure delineations where bowel cavity, femoral heads, bladder, and rectum data, with two guidelines, were classified. The impact on DL-based segmentation quality using mixed guideline training data was also demonstrated. Bowel cavity was manually delineated on CT images for anal cancer patients (n = 170) according to guidelines Devisetty and RTOG. The DL segmentation quality from using training data with coherent or mixed guidelines was investigated. A supervised 3D squeeze-and-excite SENet-154 model was trained to classify two bowel cavity delineation guidelines. In addition, a pelvis CT dataset with manual delineations from prostate cancer patients (n = 1854) was used where data with an alternative guideline for femoral heads, rectum, and bladder were generated using commercial software. The model was evaluated on internal (n = 200) and external test data (n = 99). By using mixed, compared to coherent, delineation guideline training data mean DICE score decreased 3% units, mean Hausdorff distance (95%) increased 5 mm and mean surface distance (MSD) increased 1 mm. The classification of bowel cavity test data achieved 99.8% unweighted classification accuracy, 99.9% macro average precision, 97.2% macro average recall, and 98.5% macro average F1. Corresponding metrics for the pelvis internal test data were all 99% or above and for the external pelvis test data they were 96.3%, 96.6%, 93.3%, and 94.6%. Impaired segmentation performance was observed for training data with mixed guidelines. The DL delineation classification models achieved excellent results on internal and external test data. This can facilitate automated guideline-specific data extraction while avoiding the need for consistent and correct structure labels.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-1 av 1
Typ av publikation
tidskriftsartikel (1)
Typ av innehåll
refereegranskat (1)
Författare/redaktör
Lempart, Michael (1)
Nilsson, Martin P. (1)
Jamtheim Gustafsson, ... (1)
Scherman, Jonas (1)
Lärosäte
Lunds universitet (1)
Språk
Engelska (1)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (1)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy