SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0169 7439 "

Sökning: L773:0169 7439

  • Resultat 11-20 av 65
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  • Aftab, Obaid, 1984-, et al. (författare)
  • Label free quantification of time evolving morphologies using time-lapse video microscopy enables identity control of cell lines and discovery of chemically induced differential activity in iso-genic cell line pairs
  • 2015
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - 0169-7439 .- 1873-3239. ; 141, s. 24-32
  • Tidskriftsartikel (refereegranskat)abstract
    • Label free time-lapse video microscopy based monitoring of time evolving cell population morphology has potential to offer a simple and cost effective method for identity control of cell lines. Such morphology monitoring also has potential to offer discovery of chemically induced differential changes between pairs of cell lines of interest, for example where one in a pair of cell lines is normal/sensitive and the other malignant/resistant. A new simple algorithm, pixel histogram hierarchy comparison (PHHC), for comparison of time evolving morphologies (TEM) in phase contrast time-lapse microscopy movies was applied to a set of 10 different cell lines and three different iso-genic colon cancer cell line pairs, each pair being genetically identical except for a single mutation. PHHC quantifies differences in morphology by comparing pixel histogram intensities at six different resolutions. Unsupervised clustering and machine learning based classification methods were found to accurately identify cell lines, including their respective iso-genic variants, through time-evolving morphology. Using this experimental setting, drugs with differential activity in iso-genic cell line pairs were likewise identified. Thus, this is a cost effective and expedient alternative to conventional molecular profiling techniques and might be useful as part of the quality control in research incorporating cell line models, e.g. in any cell/tumor biology or toxicology project involving drug/agent differential activity in pairs of cell line models.
  •  
12.
  • Andersson, M, et al. (författare)
  • NIR spectroscopy on moving solids using a scanning grating spectrometer - impact on multivariate process analysis
  • 2005
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439. ; 75:1, s. 1-11
  • Tidskriftsartikel (refereegranskat)abstract
    • The effect of sample movement on spectral response during fiber probe diffuse reflectance near-infrared spectrometry (NIR) sampling was characterized. This is of central importance in Process Analytical Chemistry (PAC) and Process Analytical Technology (PAT). The incitement to this study was the observation of spectral artifacts during measurements of powder samples in process streams when using a mechanically scanning spectrometer. Artifacts appeared as momentary changes in the spectral response during acquisition of a scan. These transitions emanate from continuous replacement of the sample subfraction seen by the probe and are typical for turbid media where sample properties may vary locally with respect to scattering and/or absorption. The impact on qualitative and quantitative analysis using chemometric methods such as principal component analysis (PCA) and partial least squares (PLS) regression was evaluated through experimental and theoretical simulations. It was generally found that spectra with the smallest residuals after projection onto the models came from non-moving samples or samples moving only slowly. It is shown that the magnitude of the spectral residuals is directly connected to the effective sample size, which relates both to sample speed as well as to the sample area presented to the probe. Implications for in-line/on-line process analysis of solids are discussed. (C) 2004 Elsevier B.V. All rights reserved.
  •  
13.
  • Antti, Henrik, et al. (författare)
  • Statistical experimental design and partial least squares regression analysis of biofluid metabonomic NMR and clinical chemistry data for screening of adverse drug effects
  • 2004
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439. ; 73:1, s. 139-49
  • Tidskriftsartikel (refereegranskat)abstract
    • Metabonomic analysis is increasingly recognised as a powerful approach for delineating the integrated metabolic changes in biofluids and tissues due to toxicity, disease processes or genetic modification in whole animal systems. When dealing with complex biological data sets, as generated within metabonomics, as well as related fields such as genomics and proteomics, reliability and significance of identified biomarkers associated with specific states related to toxicity or disease are crucial in order to gain detailed and relevant interpretations of the metabolic fluxes in the studied systems. Since various physiological factors, such as diet, state of health, age, diurnal cycles, stress, genetic drift, and strain differences, affect the metabolic composition of biological matrices, it is of great importance to create statistically reliable decision tools for distinguishing between physiological and pathological responses in animal models. In the screening for new biomarkers or patterns of pathological dysfunction, methods providing statistically valid measures of effect-related changes will become increasingly important as the data within areas such as genomics, proteomics and metabonomics continues to grow in size and complexity. 1H NMR spectroscopy and mass spectrometry are the principal analytical platforms used to derive the data and, because extensively large data sets are required, as much consideration has to be given to optimum design of experiments (DoE) as for subsequent data analysis. Thus, statistical experimental design combined with partial least squares (PLS) regression is proposed as an efficient approach for undertaking metabonomic studies and for analysis of the results. The method was applied to data from a liver toxicology study in the rat using hydrazine as a model toxin. 1D projections of 2D J-resolved (J-RES) 1H NMR spectra and the corresponding clinical chemistry parameters of blood serum samples from control and dosed rats (30 and 90 mg/kg) collected at 48 and 168 h post dose were analysed. Confidence intervals for the PLS regression coefficients were used to create a statistical means for screening of biomarkers in the two combined data blocks (NMR and clinical chemistry data). PLS analysis was also used to reveal the correlation pattern between the two blocks of data as well as the within the two blocks according to dose, time and the interaction dose×time.
  •  
14.
  • Björk, Anders, et al. (författare)
  • Modeling of pulp quality parameters from distribution curves extracted from process acoustic measurements on a thermo mechanical pulp (TMP) process
  • 2007
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439 .- 1873-3239. ; 85:1, s. 63-69
  • Tidskriftsartikel (refereegranskat)abstract
    • In this paper the feasibility of modeling strength and optical pulp properties from length distribution curves extracted from acoustic data using continuous wavelet transform-fiber length extraction, CWT-FLE (A Björk and L-G Danielsson, 'Extraction of Distribution Curves from Process Acoustic Measurements on a TMP-Process', Pulp and Paper Canada 105 No. 11 (2004), T260-T264) by use of Partial Least Squares (PLS) have been tested. The curves used have earlier been validated against length distribution curves obtained by analyzing pulp samples with a commercial analyzer (FiberMaster). The curves were extracted from acoustic data without any "calibration" against fiber length analyses. The acoustic measurements were performed using an accelerometer affixed to the refiner blow-line during a full-scale trial with a Sunds Defibrator double disc refiner at SCA Ortviken, Sweden. Pulp samples were collected concurrently with the acoustic measurements and extensive physical testing has been made on these samples. For each trial point three pulp samples were collected. PLS1 and PLS2 models were successfully made linking the distribution curves obtained using CWT-FLE to pulp tensile strength properties as well as optical properties. The resulting Root Mean Square Error of Prediction (RMSEP) for all parameters is comparable to what can be obtained by pooling the standard deviations of reference measurements from the different trial points. The results obtained are compared to FiberMaster data modeled in the same fashion, yielding lower prediction errors than the CWT-FLE data. However, this can be partly due to the five-year storage of pulp samples between pulp sampling/acoustic measurement and FiberMaster analyses/sheet testing. The acoustic method is fast and produces results without dead time and could constitute a new tool for improving process control and optimizing the fiber characteristics in a specific process and for a specific purpose. The technique could be implemented in a PC-environment at a fairly low cost.
  •  
15.
  • Bouveresse, D. Jouan-Rimbaud, et al. (författare)
  • Identification of significant factors by an extension of ANOVA-PCA based on multi-block analysis
  • 2011
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439 .- 1873-3239. ; 106:2, s. 173-182
  • Tidskriftsartikel (refereegranskat)abstract
    • A modification of the ANOVA-PCA method, proposed by Harrington et al. to identify significant factors and interactions in an experimental design, is presented in this article. The modified method uses the idea of multiple table analysis, and looks for the common dimensions underlying the different data tables, or data blocks, generated by the "ANOVA-step" of the ANOVA-PCA method, in order to identify the significant factors. In this paper, the "Common Component and Specific Weights Analysis" method is used to analyse the calculated multi-block data set. This new method, called AComDim, was compared to the standard ANOVA-PCA method, by analysing four real data sets. Parameters computed during the AComDim procedure enable the computation of F-values to check whether the variability of each original data block is significantly greater than that of the noise.
  •  
16.
  • Brink, Mattias, et al. (författare)
  • On-line predictions of the aspen fibre and birch bark content in unbleached hardwood pulp, using NIR spectroscopy and multivariate data analysis
  • 2010
  • Ingår i: CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS. - : Elsevier Science B.V., Amsterdam.. - 0169-7439. ; 103:1, s. 53-58
  • Tidskriftsartikel (refereegranskat)abstract
    • An on-line fibre-based near-infrared (NIR) spectrometric analyser was adapted for on-site process analysis at an integrated paperboard mill. The analyser uses multivariate techniques for the quantitative predication of the aspen fibre (aspen) and the birch bark contents of sheets of unbleached hardwood pulp. The NIR analyser is a prototype constructed from standard NIR components. The spectroscopic data was processed by using principal component analysis (PCA) and partial least square (PLS) regression. Three sample sets were collected from three experimental designs, each composed of known pulp contents of birch, aspen and birch bark. Sets I and 2 were used for model calibration and set 3 was used to validate the models. The PLS model that produced the best predictions gave an error of prediction (RMSEP) of 13% for aspen and less than 2% for birch bark. Eight components resulted in an (RX)-X-2 of 99.3%, (RY)-Y-2 of 99.6%. and Q(2) of 95.3%. For additional validation of aspen, three unbleached hardwood samples from the mills production were calculated to lie between -7% and +6%, regarding to the PIS model. When vessel cells were counted under a light microscope a value for the aspen content of 4.7% was obtained. The predictive models evaluated were suitable for quality assessments rather than quantitative determination.
  •  
17.
  • Brydegaard, Mikkel, et al. (författare)
  • Complete parameterization of temporally and spectrally resolved laser induced fluorescence data with applications in bio-photonics
  • 2015
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439. ; 142, s. 95-106
  • Tidskriftsartikel (refereegranskat)abstract
    • We present a set of spectrally and temporally resolved clinical fluorescence data-with two separate excitation wavelengths-that was recorded in vivo. We demonstrate that data in the spectral and temporal domains are in certain ways coupled and provide a method for integrated and effective parameterization of spectrally and temporally resolved fluorescence (i.e., time-resolved emission spectra). This parameterization is based on linear algebra, matrix formulation and system identification. We demonstrate how to empirically extract single exponentially decaying components and provide rectified emission spectra without prior knowledge. We investigate the potential for improved cancer diagnostics according to the reduced parameters along the various domains. In this case, in terms of cancer diagnostics, we were unable to identify any benefits of simultaneously measuring both the temporal and spectral properties of the observed fluorescence. However, we note that this may be explained by an important experimental bias present in many studies of optical cancer diagnostics, namely, that, in general, suspected lesions always differ visually from the neighboring healthy tissue. (C) 2015 Elsevier B.V. All rights reserved.
  •  
18.
  • Carlson, Johan E., et al. (författare)
  • Estimation of dielectric properties of crude oils based on IR spectroscopy
  • 2014
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439 .- 1873-3239. ; 139, s. 1-5
  • Tidskriftsartikel (refereegranskat)abstract
    • Dielectric properties of crude oils play an important role in characterization and quality control. Measuring permittivity accurately over a wide range of frequencies is, however, a time-consuming task and existing measurement methods are not easily adapted for real-time diagnostics. IR spectroscopy, on the other hand, provides rapid measurements of fundamental molecular properties.In this paper we show that by using multivariate calibration tools such as PLS regression, it is possible to extract dielectric properties of crude oils directly from IR spectra, in addition to conventional interpretation of the spectra, hence reducing the need for direct electrical measurements. Results on 16 different oil samples show that the dielectric parameters obtained with the proposed method agree well with those obtained using direct permittivity measurements. The PLS regression method has also been extended with Monte-Carlo simulation capabilities to account for uncertainties in the data
  •  
19.
  • Carlson, Johan E., et al. (författare)
  • Extracting homologous series from mass spectrometry data by projection on predefined vectors
  • 2012
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439 .- 1873-3239. ; 114, s. 36-43
  • Tidskriftsartikel (refereegranskat)abstract
    • Multivariate statistical methods, such as Principal Component Analysis (PCA), have been used extensively over the past decades as tools for extracting significant information from complex data sets. As such they are very powerful and in combination with an understanding of underlying chemical principles, they have enabled researchers to develop useful models. A drawback with the methods is that they do not have the ability to incorporate any physical / chemical model of the system being studied during the statistical analysis. In this paper we present a method that can be used as a complement to traditional chemometric tools in finding patterns in mass spectrometry data. The method uses a pre-defined set of equally spaced sequences that are assumed to be present in the data. Allowing for some uncertainty in the peak locations due to the uncertainties for the measurement instrumentation, the measured spectra are then projected onto this set. It is shown that the resulting scores can be used to identify homologous series in measured mass spectra that differ significantly between different measured samples. As opposed to PCA, the loading vectors, in this case the pre-defined homologous series, are readily interpretable.
  •  
20.
  • Chauchard, Fablen, et al. (författare)
  • Localization of embedded inclusions using detection of fluorescence: Feasibility study based on simulation data, LS-SVM modeling and EPO pre-processing
  • 2008
  • Ingår i: Chemometrics and Intelligent Laboratory Systems. - : Elsevier BV. - 0169-7439. ; 91:1, s. 34-42
  • Tidskriftsartikel (refereegranskat)abstract
    • Fluorescence spectroscopy is a useful technique for tissue diagnostics and is also a promising tool in the characterization of embedded structures in tissue. The emitted fluorescence from an embedded inclusion, marked with a fluorescent compound, is affected by several factors as the light propagates through the medium to the tissue boundary, where the fluorescence light is detected. Tissue absorption, scattering and autofluorescence, as well as the size and depth of the inclusion, affect the detected fluorescence light. The aim of this study is to investigate if the size and location of a fluorescent inclusion could be determined using models based a combination of External Parameter Orthogonalisation (EPO) and Least Squares Support Vector Machine (LS-SVM). This can be very useful for data pre-processing before a full fluorescence tomography reconstruction. The data set consisted of simulated multispectral fluorescence, where depth and radius of a spherical fluorescent inclusion were varied as well as the fluorescence contrast and optical properties of the surrounding tissue. The results showed that the non-linear models based on LS-SVM can simultaneously predict both radius and depth. It was observed that EPO acts as a useful pre-processing tool on spectra for this nonlinear model and that it was necessary to perform EPO to be able to predict the depth with the LS-SVM model. (C) 2007 Elsevier B.V. All rights reserved.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 65
Typ av publikation
tidskriftsartikel (65)
Typ av innehåll
refereegranskat (63)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Trygg, Johan (6)
Kulahci, Murat (5)
Johansson, Erik (4)
Josefson, Mats (4)
Abrahamsson, Katarin ... (4)
Geladi, Paul (3)
visa fler...
Abbas, Aamer, 1973 (2)
Andersson-Engels, St ... (2)
Engelbrektsson, Joha ... (2)
Lindholm-Sethson, Br ... (2)
Lindström, Anton (2)
Danielsson, Rolf (2)
Larsson, Rolf (1)
Josefson, M. (1)
Gustafsson, Mats (1)
Stenlund, Hans (1)
Han, S. (1)
Johansson, J (1)
Nicander, I, . (1)
Geladi, P. (1)
Ollmar, S (1)
Olsson, J. (1)
Abrahamsson, Jonas, ... (1)
Abrahamsson, Christo ... (1)
Sparen, A (1)
Lindgren, F (1)
Folestad, S (1)
Svanberg, Sune (1)
Lorén, Anders, 1974 (1)
Bergquist, Bjarne (1)
Bergquist, Jonas (1)
Sundberg, Björn (1)
Karlsson, Mikael (1)
Andersson, M (1)
Pettersson, Fredrik (1)
Nyholm, Tufve (1)
Bendsöe, Niels (1)
Svanberg, Katarina (1)
Aftab, Obaid, 1984- (1)
Fryknäs, Mårten (1)
Hammerling, Ulf (1)
Hassan, Saadia (1)
Nygren, Peter (1)
Jonsson, G (1)
Svensson, O (1)
Blennow, Kaj (1)
Landberg, Rikard, 19 ... (1)
Sandberg, Ann-Sofie, ... (1)
Lee, D. (1)
Nordgaard, Anders (1)
visa färre...
Lärosäte
Umeå universitet (20)
Uppsala universitet (8)
Luleå tekniska universitet (7)
Chalmers tekniska högskola (6)
Stockholms universitet (4)
Linköpings universitet (4)
visa fler...
Lunds universitet (4)
Mittuniversitetet (4)
Linnéuniversitetet (4)
Kungliga Tekniska Högskolan (3)
Göteborgs universitet (2)
Högskolan i Halmstad (2)
Karolinska Institutet (2)
Sveriges Lantbruksuniversitet (2)
visa färre...
Språk
Engelska (62)
Odefinierat språk (3)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (36)
Teknik (11)
Medicin och hälsovetenskap (5)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy