SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Håkansson Bo 1953) "

Sökning: WFRF:(Håkansson Bo 1953)

  • Resultat 11-20 av 124
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  •  
12.
  •  
13.
  •  
14.
  • Eeg-Olofsson, Måns, 1967, et al. (författare)
  • Evaluation of bone tissue formation in a flat surface attachment of a Bone Conduction Implant - A pilot study in a sheep model
  • 2014
  • Ingår i: Audiology & Neurotology Extra. - : S. Karger AG. - 1664-5537. ; 4:3, s. 62-76
  • Tidskriftsartikel (refereegranskat)abstract
    • The Bone Conduction Implant (BCI) is a new bone conduction hearing device implanted under intact skin. The transducer has a flat direct contact to the mastoid part of the temporal bone and no screws are used. The sound signal is transmitted from the external audio processor to the implant by means of magnetic induction. In this study, osseointegration of a flat passive BCI transducer dummy in sheep skulls was assessed using quantitative and qualitative histology as well as Cone Beam Computed Tomography (CBCT) and Computed Tomography (CT). The histology results were also related to the mechanical properties of the bone to implant interface. Eight months after the surgical implantation, histology sections of the bone close to the implant showed bone remodelling, compact bone and some degree of osseointegration. The histological findings corresponded well to the mechanical measurements indicating stiffer bone close to the implant, and unaffected skull vibration transmission. Neither CBCT nor CT had enough resolution to visualize the bone to implant interface in detail. In this study, using an animal model, it is shown that a flat implant in contact with bone, can be a feasible method for efficient vibration transmission to the skull bone.
  •  
15.
  •  
16.
  •  
17.
  •  
18.
  •  
19.
  • Eeg-Olofsson, Måns, 1967, et al. (författare)
  • Transmission of bone conducted sound – Correlation between hearing perception and cochlear vibration
  • 2013
  • Ingår i: Hearing Research. - : Elsevier. - 0378-5955 .- 1878-5891. ; 306, s. 11-20
  • Tidskriftsartikel (refereegranskat)abstract
    • The vibration velocity of the lateral semicircular canal and the cochlear promontory was measured on 16 subjects with a unilateral middle ear common cavity, using a laser Doppler vibrometer, when the stimulation was by bone conduction (BC). Four stimulation positions were used: three ipsilateral positions and one contralateral position. Masked BC pure tone thresholds were measured with the stimulation at the same four positions. Valid vibration data were obtained at frequencies between 0.3 and 5.0 kHz. Large intersubject variation of the results was found with both methods. The difference in cochlear velocity with BC stimulation at the four positions varied as a function of frequency while the tone thresholds showed a tendency of lower thresholds with stimulation at positions close to the cochlea. The correlation between the vibration velocities of the two measuring sites of the otic capsule was high. Also, relative median data showed similar trends for both vibration and threshold measurements. However, due to the high variability for both vibration and perceptual data, low correlation between the two methods was found at the individual level. The results from this study indicated that human hearing perception from BC sound can be estimated from the measure of cochlear vibrations of the otic capsule. It also showed that vibration measurements of the cochlea in cadaver heads are similar to that measured in live humans.
  •  
20.
  • Fredén Jansson, Karl-Johan, 1988, et al. (författare)
  • Bone Conduction Stimulated VEMP Using the B250 Transducer
  • 2021
  • Ingår i: Medical Devices: Evidence and Research. - 1179-1470. ; 14, s. 225-237
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Bone conduction (BC) stimulation is rarely used for clinical testing of vestibular evoked myogenic potentials (VEMPs) due to the limitations of conventional stimulation alternatives. The aim of this study is to compare VEMP using the new B250 transducer with the Minishaker and air conduction (AC) stimulation. Methods: Thirty normal subjects between 20 and 37 years old and equal gender distribution were recruited, 15 for ocular VEMP and 15 for cervical VEMP. Four stimulation conditions were compared: B250 on the mastoid (FM); Minishaker and B250 on the forehead (FZ); and AC stimulation using an insert earphone. Results: It was found that B250 at FM required a statistically significant lower hearing level than with AC stimulation, in average 41 dB and 35 dB lower for ocular VEMP and cervical VEMP, respectively, but gave longer n10 (1.1 ms) and n23 (1.6 ms). No statistical difference was found between B250 at FM and Minishaker at FZ. Conclusion: VEMP stimulated with B250 at FM gave similar response as the Minishaker at FZ and for a much lower hearing level than AC stimulation using insert earphones.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-20 av 124
Typ av publikation
tidskriftsartikel (85)
konferensbidrag (35)
annan publikation (2)
doktorsavhandling (1)
bokkapitel (1)
Typ av innehåll
refereegranskat (110)
övrigt vetenskapligt/konstnärligt (14)
Författare/redaktör
Håkansson, Bo, 1953 (124)
Reinfeldt, Sabine, 1 ... (47)
Eeg-Olofsson, Måns, ... (35)
Stenfelt, Stefan, 19 ... (34)
Fredén Jansson, Karl ... (30)
Ortiz Catalan, Max J ... (23)
visa fler...
Tjellström, Anders (18)
Carlsson, Peder, 195 ... (18)
Brånemark, Rickard, ... (15)
Mastinu, Enzo, 1987 (9)
Granström, Gösta, 19 ... (6)
Rosenhall, U (5)
Stenfelt, Stefan (3)
Stalfors, Joacim, 19 ... (3)
Tengstrand, Tomas (3)
Brandt, A. (2)
Wessberg, Johan, 196 ... (2)
Finizia, Caterina, 1 ... (2)
Johansson, Carina B. ... (2)
Jönsson, Radoslava, ... (2)
Cipriani, C (2)
Clemente, F. (2)
Brandt, Anders (1)
Lindström, J. (1)
Ahlberg, Johan (1)
Hultcrantz, M (1)
Bance, Manohar (1)
Lund, Henrik, 1975 (1)
Hermansson, Liselott ... (1)
Johannsen, L. (1)
Controzzi, Marco (1)
Cipriani, Christian (1)
Johansson, B.R. (1)
Barbara, Maurizio (1)
Lidén, G (1)
Mueller, Alexander (1)
Kulbacka-Ortiz, Kata ... (1)
Rosenbom, Tove (1)
Aszmann, Oskar C. (1)
Leijon, Arne (1)
Holmberg, Marcus (1)
Lassaletta, Luis (1)
Westin, Magnus (1)
Ringdahl, A. (1)
Israelsson, Björn (1)
Jönsson, R. (1)
Clemente, Francesco (1)
Ringdahl, Anders, 19 ... (1)
Nilsson, Niclas (1)
Sassu, Paolo (1)
visa färre...
Lärosäte
Chalmers tekniska högskola (124)
Göteborgs universitet (45)
Linköpings universitet (10)
Karolinska Institutet (4)
Kungliga Tekniska Högskolan (1)
Örebro universitet (1)
visa fler...
Linnéuniversitetet (1)
visa färre...
Språk
Engelska (123)
Tyska (1)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (59)
Teknik (45)
Naturvetenskap (44)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy