SwePub
Sök i SwePub databas

  Extended search

Träfflista för sökning "WFRF:(Pearce S. H.) srt2:(2005-2009)"

Search: WFRF:(Pearce S. H.) > (2005-2009)

  • Result 11-19 of 19
Sort/group result
   
EnumerationReferenceCoverFind
11.
  • Stork, D., et al. (author)
  • Overview of transport, fast particle and heating and current drive physics using tritium in JET plasmas
  • 2005
  • In: Nuclear Fusion. - 0029-5515 .- 1741-4326. ; 45:10, s. S181-S194
  • Journal article (peer-reviewed)abstract
    • Results are presented from the JET Trace Tritium Experimental (TTE) campaign using minority tritium (T) plasmas (n(T)/n(D) < 3%). Thermal tritium particle transport coefficients (D-T, nu(T)) are found to exceed neo-classical values in all regimes, except in ELMy H-modes at high densities and in the region of internal transport barriers (ITBs) in reversed shear plasmas. In ELMy H-mode dimensionless parameter scans, at q(95) 2.8 and triangularity delta = 0.2, the T particle transport scales in a gyro-Bohm manner in the inner plasma (r/a < 0.4), whilst the outer plasma particle transport scaling is more Bohm-like. Dimensionless parameter scans show contrasting behaviour for the trace particle confinement (increases with collisionality, nu* and beta) and bulk energy confinement (decreases with nu* and is independent of beta). In an extended ELMy H-mode data set, with rho*, nu*, and q varied but with neo-classical tearing modes (NTMs) either absent or limited to weak, benign core modes (4/3 or above), the multiparameter fit to the normalized diffusion coefficient in the outer plasma (0.65 < r/a < 0.8) gives D-T/B-phi similar to rho*(2.46) nu*(-0.23) beta(-1.01) q(2.03). In hybrid scenarios (q(min) similar to 1, low positive shear, no sawteeth), the T particle confinement is found to scale with increasing triangularity and plasma current. Comparing regimes (ELMy H-mode, ITB plasma and hybrid scenarios) in the outer plasma region, a correlation of high values of D-T with high values Of nu(T) is seen. The normalized diffusion coefficients for the hybrid and ITB scenarios do not fit the scaling derived for ELMy H-modes. The normalized tritium diffusion scales with normalized poloidal Larmor radius (rho(theta)* = q rho*) in a manner close to gyro-Bohm (similar to rho(sigma)*(3)), with an added inverse P dependence. The effects of ELMs, sawteeth and NTMs on the T particle transport are described. Fast-ion confinement in current-hole (CH) plasmas was tested in TTE by tritium neutral beam injection into JET CH plasmas. gamma-rays from the reactions of fusion alpha and beryllium impurities (Be-9(alpha, n gamma)C-12) characterized the fast fusion-alpha population evolution. The gamma-decay times are consistent with classical alpha plus parent fast triton slowing down times (tau(Ts) + tau(alpha s)) for high plasma currents (I-p > 2 MA) and monotonic q-profiles. In CH discharges the gamma-ray emission decay times are much lower than classical (tau(Ts) + tau(alpha s)), indicating alpha confinement degradation, due to the orbit losses and particle orbit drift predicted by a 3-D Fokker-Planck numerical code and modelled using TRANSP.
  •  
12.
  • Tanaka, T., et al. (author)
  • Data acquisition system for the PoGOLite astronomical hard X-ray polarimeter
  • 2007
  • In: Nuclear Science Symposium Conference Record, 2007. - 9781424409228 ; , s. 445-449, s. 445-449
  • Conference paper (other academic/artistic)abstract
    • The PoGOLite is a new balloon-borne instrument to measure the polarization of hard X-rays/soft gamma-rays in the 25-80 keV energy range for the first time. In order to detect the polarization, PoGOLite measures the azimuthal angle asymmetry of Compton scattering and the subsequent photo-absorption in an array of detectors. This array consists of 217 well-type phoswich detector cells (PDCs) surrounded by a side anti-coincidence shield (SAS) composed of 54 segments of BGO crystals. At balloon altitude, the intensity of backgrounds due to cosmic-ray charged particles, atmospheric gamma-rays and neutrons is extremely high, typically a few hundred Hz per unit. Hence the data acquisition (DAQ) system of PoGOLite is required to handle more than 270 signals simultaneously, and detect weak signals from astrophysical objects (100mCrab, 1.5 cs(-1) in 25-80 keV) under such a severe environment. We have developed a new DAQ system consisting of front-end electronics, waveform digitizer, Field Programmable Gate Array (FPGA) and a microprocessor. In this system, all output signals of PDC / SAS are fed into individual charge-sensitive amplifier and then digitized to 12 bit accuracy at 24 MSa/s by pipelined analog to digital converters. A DAQ board for the PDC records waveforms which will be examined in an off-line analysis to distinguish signals from the background events and measure the energy spectrum and polarization of targets. A board for the SAS records hit pattern to be used for background rejection. It also continuously records a pulse-height analysis (PHA) histogram to monitor incident background flux. These basic functions of the DAQ system were verified in a series of beam tests.
  •  
13.
  • Kanai, Y., et al. (author)
  • Beam test of a prototype phoswich detector assembly for the PoGOLite astronomical soft gamma-ray polarimeter
  • 2007
  • In: Nuclear Instruments and Methods in Physics Research Section A. - : Elsevier BV. - 0168-9002 .- 1872-9576. ; 570:1, s. 61-71
  • Journal article (peer-reviewed)abstract
    • We report about the beam test on a prototype of the balloon-based astronomical soft gamma-ray polarimeter, PoGOLite (Polarized Gamma-ray Observer-Light Version) conducted at KEK Photon Factory, a synchrotron radiation facility in Japan. The synchrotron beam was set at 30, 50, and 70 keV and its polarization was monitored by a calibrated polarimeter. The goal of the experiment was to validate the flight design of the polarimeter. PoGOLite is designed to measure polarization by detecting a Compton scattering and the subsequent photo-absorption in an array of 217 well-type phoswich detector cells (PDCs). The test setup included a first flight model PDC and a front-end electronics to select and reconstruct valid Compton scattering events. The experiment has verified that the flight PDC can detect recoil electrons and select valid Compton scattering events down to 30 keV from background. The measure azimuthal modulations (34.4%, 35.8% and 37.2% at 30, 50, and 70 keV, respectively) agreed within 10% (relative) with the predictions by Geant4 implemented with dependence on the initial and final photon polarizations.
  •  
14.
  • Mizuno, T., et al. (author)
  • High sensitivity balloon-borne hard X-ray/soft Gamma-Ray Polarimeter PoGOLite
  • 2007
  • In: Nuclear Science Symposium Conference Record, 2007. NSS ’07. IEEE. - : IEEE. - 9781424409228 ; , s. 2538-2544
  • Conference paper (peer-reviewed)abstract
    • The Polarized Gamma-ray Observer - Lightweight version (PoGOLite) is a new balloon experiment capable of detecting 10% polarization from a 200 mCrab source in the 25-80 keV energy range in a single 6-hour flight for the first time. Polarization measurements of hard X-rays and soft gamma-rays are expected to provide a powerful probe into high-energy emission mechanisms as well as source geometries. PoGOLite uses Compton scattering and photo-absorption to measure polarization in an array of 217 well-type phoswich detector cells made of plastic and BGO scintillators. The adoption of a well-type phoswich counter concept and a thick polyethylene neutron shield provides a narrow field-of-view (1.25 msr), a large effective area ( gt; 250 cm2 at 40-50 keV), a high modulation factor (more than 25%) and the low background ( 100 mCrab) required to conduct high-sensitivity polarization measurements. Through tests in laboratories and accelerator facilities of a scaled-down prototype with the front-end electronics of flight design and an extensive study by Monte Carlo simulation, we have demonstrated high instrument performance. PoGOLite will be ready for a first engineering flight in 2009 and a science flight in 2010, during which polarization signals from the Crab Nebula/pulsar, Cygnus X-1 and other objects will be observed.
  •  
15.
  • Kiss, Mózsi, et al. (author)
  • The PoGOLite balloon-borne soft gamma-ray polarimeter
  • 2008
  • In: COOL DISCS, HOT FLOWS. - : AIP. ; , s. 225-232
  • Conference paper (peer-reviewed)abstract
    • Linearly polarized radiation in the hard X-ray/soft gamma-ray band is expected from a large variety of astronomical sources. We discuss the importance of polarimetric studies for several classes of sources - pulsars, accreting black holes. magnetic neutron stars and jets from active galaxies - and then describe PoGOLite, a balloon-borne instrument which is currently under construction and will be able to measure the polarization of electromagnetic radiation from such extra-solar objects in the energy range 25-80 keV.
  •  
16.
  • Owen, Christopher G, et al. (author)
  • Does initial breastfeeding lead to lower blood cholesterol in adult life? A quantitative review of the evidence.
  • 2008
  • In: American Journal of Clinical Nutrition. - 0002-9165 .- 1938-3207. ; 88:2, s. 305-14
  • Journal article (peer-reviewed)abstract
    • BACKGROUND: Earlier studies have suggested that infant feeding may program long-term changes in cholesterol metabolism. OBJECTIVE: We aimed to examine whether breastfeeding is associated with lower blood cholesterol concentrations in adulthood. DESIGN: The study consisted of a systematic review of published observational studies relating initial infant feeding status to blood cholesterol concentrations in adulthood (ie, aged >16 y). Data were available from 17 studies (17 498 subjects; 12 890 breastfed, 4608 formula-fed). Mean differences in total cholesterol concentrations (breastfed minus formula-fed) were pooled by using fixed-effect models. Effects of adjustment (for age at outcome, socioeconomic position, body mass index, and smoking status) and exclusion (of nonexclusive breast feeders) were examined. RESULTS: Mean total blood cholesterol was lower (P = 0.037) among those ever breastfed than among those fed formula milk (mean difference: -0.04 mmol/L; 95% CI: -0.08, 0.00 mmol/L). The difference in cholesterol between infant feeding groups was larger (P = 0.005) and more consistent in 7 studies that analyzed "exclusive" feeding patterns (-0.15 mmol/L; -0.23, -0.06 mmol/L) than in 10 studies that analyzed nonexclusive feeding patterns (-0.01 mmol/L; -0.06, 0.03 mmol/L). Adjustment for potential confounders including socioeconomic position, body mass index, and smoking status in adult life had minimal effect on these estimates. CONCLUSIONS: Initial breastfeeding (particularly when exclusive) may be associated with lower blood cholesterol concentrations in later life. Moves to reduce the cholesterol content of formula feeds below those of breast milk should be treated with caution.
  •  
17.
  • Takahashi, H., et al. (author)
  • Beam test results of the polarized gamma-ray observer, PoGOLite
  • 2008
  • In: 2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9. - 9781424427147 ; , s. 732-736
  • Conference paper (peer-reviewed)abstract
    • The Polarized Gamma-ray Observer, PoGOLite, is a balloon experiment with the capability of detecting 10% polarization from a 200 mCrab celestial object in the energy range 25 #x2013;80 keV. During a beam test at KEK-PF in February 2008, 20 detector units were assembled, and a 50 keV X-ray beam with a polarization degree of #x223C;90% was irradiated at the center unit. Signals from all 20 units were fed into flightversion electronics consisting of six circuit boards (four waveform digitizer boards, one digital I/O board and one router board) and one microprocessor (SpaceCube), which communicate using a SpaceWire interface. One digitizer board, which can associate up to 8 PDCs, outputs a trigger signal. The digital I/O board handles the trigger and returns a data acquisition request if there is no veto signal (upper or pulse-shape discriminators) from any detector unit. This data acquisition system worked well, and the modulation factor was successfully measured to be #x223C;34%. These results confirmed the capabilities of both detector and data-acquisition system for a pathfinder flight planned in 2010.
  •  
18.
  • Axelsson, Magnus, et al. (author)
  • Measuring energy dependent polarization in soft gamma-rays using compton scattering in PoGOLite
  • 2007
  • In: Astroparticle physics. - : Elsevier. - 0927-6505 .- 1873-2852. ; 28:3, s. 327-337
  • Journal article (peer-reviewed)abstract
    • Linear polarization in X-and gamma-rays is an important diagnostic of many astrophysical sources, foremost giving information about their geometry, magnetic fields, and radiation mechanisms. However, very few X-ray polarization measurements have been made, and then only mono-energetic detections, whilst several objects are assumed to have energy dependent polarization signatures. In this paper, we investigate whether detection of energy dependent polarization from cosmic sources is possible using the Compton technique, in particular with the proposed PoGOLite balloon-experiment, in the 25-100 keV range. We use Geant4 simulations of a PoGOLite model and input photon spectra based on Cygnus X-1 and accreting magnetic pulsars (100 mCrab). Effective observing times of 6 and 35 h were simulated, corresponding to a standard and a long duration flight, respectively. Both smooth and sharp energy variations of the polarization are investigated and compared to constant polarization signals using chi-square statistics. We can reject constant polarization, with energy, for the Cygnus X-1 spectrum (in the hard state), if the reflected component is assumed to be completely polarized, whereas the distinction cannot be made for weaker polarization. For the accreting pulsar, constant polarization can be rejected in the case of polarization in a narrow energy band with at least 50% polarization, and similarly for a negative step distribution from 30% to 0% polarization.
  •  
19.
  •  
Skapa referenser, mejla, bekava och länka
  • Result 11-19 of 19

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view