SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Sigfridsson J) "

Sökning: WFRF:(Sigfridsson J)

  • Resultat 11-18 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
11.
  •  
12.
  • Kvitting, J.P., et al. (författare)
  • Analysis of human myocardial dynamics using virtual markers based on magnetic resonance imaging
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - 1475-0961 .- 1475-097X. ; 30:1, s. 23-29
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Myocardial dynamics are three-dimensional (3D) and time-varying. Cineradiography of surgically implanted makers in animals or patients is accurate for assessing these events, but this invasive method potentially alters myocardial motion. The aim of the study was to quantify myocardial motion using magnetic resonance imaging (MRI) and hence to provide a non-invasive approach to characterize 3D myocardial dynamics. Methods: Myocardial motion was quantified in ten normal volunteers by tracking the Lagrangian motion of individual points (i.e. virtual markers), based on time-resolved 3D phase-contrast MRI data and Fourier tracking. Nine points in the myocardium were tracked over the entire cardiac cycle, allowing a wire frame model to be generated and systolic and diastolic events identified. Results: Radius of curvature of the left ventricular (LV) wall was calculated from the virtual markers; the ratio between the anterior–posterior (AP) and septal–lateral (SL) walls in the LV shows an oval shape of the apical short axis plane at end systole (ES) and more circular at end diastole (ED). The AP/SL ratio for the basal plane shows an oval shape at ES and ED. We found that the rotation of the basal plane in ES was less compared to the apical plane [−2·0 ± 2·2 versus 4·1 ± 2·6 degrees (P<0·005)]. The apical plane rotated counter clock wise as viewed from the apex. Conclusion: This new non-invasive tool, despite current limitations in temporal and spatial resolution, may provide a comprehensive set of virtual myocardial markers throughout the entire LV without the confounding effects introduced by surgical implantation.
  •  
13.
  • Micheal Raj, Pushparani, et al. (författare)
  • Fabrication and characterisation of a silicon-borosilicate glass microfluidic device for synchrotron-based hard X-ray spectroscopy studies
  • 2021
  • Ingår i: RSC Advances. - : Royal Society of Chemistry. - 2046-2069. ; 11:47, s. 29859-29869
  • Tidskriftsartikel (refereegranskat)abstract
    • Some of the most fundamental chemical building blocks of life on Earth are the metal elements. X-ray absorption spectroscopy (XAS) is an element-specific technique that can analyse the local atomic and electronic structure of, for example, the active sites in catalysts and energy materials and allow the metal sites in biological samples to be identified and understood. A microfluidic device capable of withstanding the intense hard X-ray beams of a 4th generation synchrotron and harsh chemical sample conditions is presented in this work. The device is evaluated at the K-edges of iron and bromine and the L-3-edge of lead, in both transmission and fluorescence mode detection and in a wide range of sample concentrations, as low as 0.001 M. The device is fabricated in silicon and glass with plasma etched microchannels defined in the silicon wafer before anodic bonding of the glass wafer into a complete device. The device is supported with a well-designed printed chip holder that made the microfluidic device portable and easy to handle. The chip holder plays a pivotal role in mounting the delicate microfluidic device on the beamline stage. Testing validated that the device was sufficiently robust to contain and flow through harsh acids and toxic samples. There was also no significant radiation damage to the device observed, despite focusing with intense X-ray beams for multiple hours. The quality of X-ray spectra collected is comparable to that from standard methods; hence we present a robust microfluidic device to analyse liquid samples using synchrotron XAS.
  •  
14.
  •  
15.
  • Nickander, J, et al. (författare)
  • Females have higher myocardial perfusion, blood volume and extracellular volume compared to males - an adenosine stress cardiovascular magnetic resonance study
  • 2020
  • Ingår i: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 10380-
  • Tidskriftsartikel (refereegranskat)abstract
    • Knowledge on sex differences in myocardial perfusion, blood volume (MBV), and extracellular volume (ECV) in healthy individuals is scarce and conflicting. Therefore, this was investigated quantitatively by cardiovascular magnetic resonance (CMR). Healthy volunteers (n = 41, 51% female) underwent CMR at 1.5 T. Quantitative MBV [%] and perfusion [ml/min/g] maps were acquired during adenosine stress and at rest following an intravenous contrast bolus (0.05 mmol/kg, gadobutrol). Native T1 maps were acquired before and during adenosine stress, and after contrast (0.2 mmol/kg) at rest and during adenosine stress, rendering rest and stress ECV maps. Compared to males, females had higher perfusion, ECV, and MBV at stress, and perfusion and ECV at rest (p < 0.01 for all). Multivariate linear regression revealed that sex and MBV were associated with perfusion (sex beta −0.31, p = 0.03; MBV beta −0.37, p = 0.01, model R2 = 0.29, p < 0.01) while sex and hematocrit were associated with ECV (sex beta −0.33, p = 0.03; hematocrit beta −0.48, p < 0.01, model R2 = 0.54, p < 0.001). Myocardial perfusion, MBV, and ECV are higher in female healthy volunteers compared to males. Sex is an independent contributor to perfusion and ECV, beyond other physiological factors that differ between the sexes. These findings provide mechanistic insight into sex differences in myocardial physiology.
  •  
16.
  • Raj, Pushparani, et al. (författare)
  • Fabrication and characterisation of a silicon-borosilicate glass microfluidic device for synchrotron-based hard X-ray spectroscopy studies
  • 2021
  • Ingår i: RSC Advances. - Cambridge : RSC Publishing. - 2046-2069. ; 11:47, s. 29859-29869
  • Tidskriftsartikel (refereegranskat)abstract
    • Some of the most fundamental chemical building blocks of life on Earth are the metal elements. X-ray absorption spectroscopy (XAS) is an element-specific technique that can analyse the local atomic and electronic structure of, for example, the active sites in catalysts and energy materials and allow the metal sites in biological samples to be identified and understood. A microfluidic device capable of withstanding the intense hard X-ray beams of a 4th generation synchrotron and harsh chemical sample conditions is presented in this work. The device is evaluated at the K-edges of iron and bromine and the L3-edge of lead, in both transmission and fluorescence mode detection and in a wide range of sample concentrations, as low as 0.001 M. The device is fabricated in silicon and glass with plasma etched microchannels defined in the silicon wafer before anodic bonding of the glass wafer into a complete device. The device is supported with a well-designed printed chip holder that made the microfluidic device portable and easy to handle. The chip holder plays a pivotal role in mounting the delicate microfluidic device on the beamline stage. Testing validated that the device was sufficiently robust to contain and flow through harsh acids and toxic samples. There was also no significant radiation damage to the device observed, despite focusing with intense X-ray beams for multiple hours. The quality of X-ray spectra collected is comparable to that from standard methods; hence we present a robust microfluidic device to analyse liquid samples using synchrotron XAS.
  •  
17.
  • Ramos, J. G., et al. (författare)
  • Comprehensive Cardiovascular Magnetic Resonance Diastolic Dysfunction Grading Shows Very Good Agreement Compared With Echocardiography
  • 2020
  • Ingår i: Jacc-Cardiovascular Imaging. - : Elsevier BV. - 1936-878X .- 1876-7591. ; 13:12, s. 2530-2542
  • Tidskriftsartikel (refereegranskat)abstract
    • OBJECTIVES The aims of this study were to develop a comprehensive cardiovascular magnetic resonance (CMR) approach to diastolic dysfunction (DD) grading and to evaluate the accuracy of CMR in the diagnosis of DD compared with echocardiography. BACKGROUND Left ventricular DD is routinely assessed using echocardiography. METHODS Consecutive clinically referred patients (n = 46; median age 59 years; interquartile range: 46 to 68 years; 33% women) underwent both conventional echocardiography and CMR. CMR diastolic transmitral velocities (E and A) and myocardial tissue velocity (e0) were measured during breath-hold using a validated high-temporal resolution radial sector-wise golden-angle velocity-encoded sequence. CMR pulmonary artery pressure was estimated from 4-dimensional flow analysis of blood flow vortex duration in the pulmonary artery. CMR left atrial volume was measured using the biplane long-axis area-length method. Both CMR and echocardiographic data were used to perform blinded grading of DD according to the 2016 joint American and European recommendations. RESULTS Grading of DD by CMR agreed with that by echocardiography in 43 of 46 cases (93%), of which 9% were normal, 2% indeterminate, 63% grade 1 DD, 4% grade 2 DD, and 15% grade 3 DD. There was a very good categorical agreement, with a weighted Cohen kappa coefficient of 0.857 (95% confidence interval: 0.73 to 1.00; p < 0.001). CONCLUSIONS A comprehensive CMR protocol for grading DD encompassing diastolic blood and myocardial velocities, estimated pulmonary artery pressure, and left atrial volume showed very good agreement with echocardiography. (C) 2020 by the American College of Cardiology Foundation.
  •  
18.
  • Sigfridsson, Kalle, 1964, et al. (författare)
  • Usefulness of a Nanoparticle Formulation to Investigate Some Hemodynamic Parameters of a Poorly Soluble Compound
  • 2011
  • Ingår i: Journal of Pharmaceutical Sciences. - : Elsevier BV. - 1520-6017 .- 0022-3549. ; 100:6, s. 2194-2202
  • Tidskriftsartikel (refereegranskat)abstract
    • Drug solubility is an important issue when progressing investigational compounds into clinical candidates. The present paper describes the development and characterization of a nanosuspension that was formulated to overcome problems with poor water solubility and possible adverse events caused by cosolvent mixtures, using ticagrelor as a model compound. A homogeneous nanosuspension of ticagrelor was formed using a wet milling approach, which yielded particle sizes around 230 nm. The nanosuspensions were chemically stable for at least 10 months at both room temperature and when refrigerated, and physically (i.e., particle size) stable for at least 10 months under refrigeration, and approximately 3 years at room temperature and when frozen. One rat model and two dog models were used to assess the pharmacokinetics and hemodynamic-related effects following intravenous administration of nanoparticles. There were no biologically consistent or dose-dependent effects of the nanoparticles on the hemodynamic parameters tested, that is, heart rate, mean aortic pressure, cardiac output, left femoral artery blood flow, or cardiac inotropy (measured as max dP/dt). In conclusion, a stable ticagrelor nanosuspension formulation was developed, suitable for intravenous administration. At the doses evaluated, this formulation was without hemodynamic effects in three sensitive preclinical models. (C) 2010 Wiley-Liss, Inc. and the American Pharmacists Association J Pharm Sci 100:2194-2202, 2011
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 11-18 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy