SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "((L773:1522 2586)) srt2:(2015-2019)"

Sökning: ((L773:1522 2586)) > (2015-2019)

  • Resultat 1-10 av 35
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alamidi, Daniel, et al. (författare)
  • Variable Flip Angle 3D Ultrashort Echo Time (UTE) T-1 Mapping of Mouse Lung: A Repeatability Assessment
  • 2018
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 48:3, s. 846-852
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Lung T-1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T-1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. Purpose: To evaluate the feasibility of regional lung T-1 quantification with VFA 3D-UTE and to investigate long-and short-term T-1 repeatability in the lungs of naive mice. Field strength/Sequence: 3D free-breathing radial UTE (8 mu s) at 4.7T. Assessment: VFA 3D-UTE T-1 calculations were validated against T-1 values measured with inversion recovery (IR) in phantoms. Lung T-1 and proton density (S-0) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T-1 measurements were performed during one of the imaging sessions. Statistical Tests: Agreement in T-1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson's correlation analysis. The T-1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. Results: Good T-1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T-1 in lung and muscle showed a 5% and 3% CV (1255 +/- 63 msec and 1432 +/- 42 msec, respectively, mean +/- SD) with no changes in T-1 or S-0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T-1 and S-0. Data Conclusion: VFA 3D-UTE shows promise as a reliable T-1 mapping method that enables full lung coverage, high signal-to-noise ratio (similar to 25), and spatial resolution (300 mu m) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies.
  •  
2.
  • Andersson, Thord, et al. (författare)
  • Consistent intensity inhomogeneity correction in water-fat MRI
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 42:2
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To quantitatively and qualitatively evaluate the water-signal performance of the consistent intensity inhomogeneity correction (CIIC) method to correct for intensity inhomogeneitiesMETHODS: Water-fat volumes were acquired using 1.5 Tesla (T) and 3.0T symmetrically sampled 2-point Dixon three-dimensional MRI. Two datasets: (i) 10 muscle tissue regions of interest (ROIs) from 10 subjects acquired with both 1.5T and 3.0T whole-body MRI. (ii) Seven liver tissue ROIs from 36 patients imaged using 1.5T MRI at six time points after Gd-EOB-DTPA injection. The performance of CIIC was evaluated quantitatively by analyzing its impact on the dispersion and bias of the water image ROI intensities, and qualitatively using side-by-side image comparisons.RESULTS: CIIC significantly ( P1.5T≤2.3×10-4,P3.0T≤1.0×10-6) decreased the nonphysiological intensity variance while preserving the average intensity levels. The side-by-side comparisons showed improved intensity consistency ( Pint⁡≤10-6) while not introducing artifacts ( Part=0.024) nor changed appearances ( Papp≤10-6).CONCLUSION: CIIC improves the spatiotemporal intensity consistency in regions of a homogenous tissue type.
  •  
3.
  • Calamante, Fernando, et al. (författare)
  • MR System Operator: Recommended Minimum Requirements for Performing MRI in Human Subjects in a Research Setting
  • 2015
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1522-2586 .- 1053-1807. ; 41:4, s. 899-902
  • Forskningsöversikt (refereegranskat)abstract
    • This article is intended to provide guidelines for the minimum level of safety and operational knowledge that an MR system operator should exhibit in order to safely perform an MR procedure in a human subject in a research setting. This article represents the position of the International Society for Magnetic Resonance in Medicine (ISMRM) regarding this important topic and was developed by members of this society's MR Safety Committee. J. Magn. Reson. Imaging 2015;41:899-902. (c) 2014 Wiley Periodicals, Inc.
  •  
4.
  •  
5.
  • Cibis, Merih, et al. (författare)
  • Creating Hemodynamic Atlases of Cardiac 4D Flow MRI
  • 2017
  • Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY. - 1053-1807 .- 1522-2586. ; 46:5, s. 1389-1399
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Hemodynamic atlases can add to the pathophysiological understanding of cardiac diseases. This study proposes a method to create hemodynamic atlases using 4D Flow magnetic resonance imaging (MRI). The method is demonstrated for kinetic energy (KE) and helicity density (Hd). Materials and Methods: Thirteen healthy subjects underwent 4D Flow MRI at 3T. Phase-contrast magnetic resonance cardioangiographies (PC-MRCAs) and an average heart were created and segmented. The PC-MRCAs, KE, and Hd were nonrigidly registered to the average heart to create atlases. The method was compared with 1) rigid, 2) affine registration of the PC-MRCAs, and 3) affine registration of segmentations. The peak and mean KE and Hd before and after registration were calculated to evaluate interpolation error due to nonrigid registration. Results: The segmentations deformed using nonrigid registration overlapped (median: 92.3%) more than rigid (23.1%, P amp;lt; 0.001), and affine registration of PC-MRCAs (38.5%, P amp;lt; 0.001) and affine registration of segmentations (61.5%, P amp;lt; 0.001). The peak KE was 4.9 mJ using the proposed method and affine registration of segmentations (P50.91), 3.5 mJ using rigid registration (P amp;lt; 0.001), and 4.2 mJ using affine registration of the PC-MRCAs (P amp;lt; 0.001). The mean KE was 1.1 mJ using the proposed method, 0.8 mJ using rigid registration (P amp;lt; 0.001), 0.9 mJ using affine registration of the PC-MRCAs (P amp;lt; 0.001), and 1.0 mJ using affine registration of segmentations (P50.028). The interpolation error was 5.262.6% at mid-systole, 2.863.8% at early diastole for peak KE; 9.669.3% at mid-systole, 4.064.6% at early diastole, and 4.964.6% at late diastole for peak Hd. The mean KE and Hd were not affected by interpolation. Conclusion: Hemodynamic atlases can be obtained with minimal user interaction using nonrigid registration of 4D Flow MRI. Level of Evidence: 2 Technical Efficacy: Stage 1
  •  
6.
  • Covarrubias, Yesenia, et al. (författare)
  • Pilot study on longitudinal change in pancreatic proton density fat fraction during a weight-loss surgery program in adults with obesity
  • 2019
  • Ingår i: Journal of Magnetic Resonance Imaging. - : WILEY. - 1053-1807 .- 1522-2586. ; 50:4, s. 1092-1102
  • Tidskriftsartikel (refereegranskat)abstract
    • Background Quantitative-chemical-shift-encoded (CSE)-MRI methods have been applied to the liver. The feasibility and potential utility CSE-MRI in monitoring changes in pancreatic proton density fat fraction (PDFF) have not yet been demonstrated. Purpose To use quantitative CSE-MRI to estimate pancreatic fat changes during a weight-loss program in adults with severe obesity and nonalcoholic fatty liver disease (NAFLD). To explore the relationship of reduction in pancreatic PDFF with reductions in anthropometric indices. Study Type Prospective/longitudinal. Population Nine adults with severe obesity and NAFLD enrolled in a weight-loss program. Field Strength/Sequence CSE-MRI fat quantification techniques and multistation-volumetric fat/water separation techniques were performed at 3 T. Assessment PDFF values were recorded from parametric maps colocalized across timepoints. Statistical Tests Rates of change of log-transformed variables across time were determined (linear-regression), and their significance assessed compared with no change (Wilcoxon test). Rates of change were correlated pairwise (Spearmans correlation). Results Mean pancreatic PDFF decreased by 5.7% (range 0.7-17.7%) from 14.3 to 8.6%, hepatic PDFF by 11.4% (2.6-22.0%) from 14.8 to 3.4%, weight by 30.9 kg (17.3-64.2 kg) from 119.0 to 88.1 kg, body mass index by 11.0 kg/m(2) (6.3-19.1 kg/m(2)) from 44.1 to 32.9 kg/m(2), waist circumference (WC) by 25.2 cm (4.0-41.0 cm) from 133.1 to 107.9 cm, HC by 23.5 cm (4.5-47.0 cm) from 135.8 to 112.3 cm, visceral adipose tissue (VAT) by 2.9 L (1.7-5.7 L) from 7.1 to 4.2 L, subcutaneous adipose tissue (SCAT) by 4.0 L (2.9-7.4 L) from 15.0 to 11.0 L. Log-transformed rate of change for pancreatic PDFF was moderately correlated with log-transformed rates for hepatic PDFF, VAT, SCAT, and WC (rho = 0.5, 0.47, 0.45, and 0.48, respectively), although not statistically significant. Data Conclusion Changes in pancreatic PDFF can be estimated by quantitative CSE-MRI in adults undergoing a weight-loss surgery program. Pancreatic and hepatic PDFF and anthropometric indices decreased significantly. Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2019;50:1092-1102.
  •  
7.
  •  
8.
  • Dunås, Tora, et al. (författare)
  • Accuracy of blood flow assessment in cerebral arteries with 4D flow MRI : Evaluation with three segmentation methods
  • 2019
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley. - 1053-1807 .- 1522-2586. ; 50:2, s. 511-518
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Accelerated 4D flow MRI allows for high‐resolution velocity measurements with whole‐brain coverage. Such scans are increasingly used to calculate flow rates of individual arteries in the vascular tree, but detailed information about the accuracy and precision in relation to different postprocessing options is lacking.Purpose: To evaluate and optimize three proposed segmentation methods and determine the accuracy of in vivo 4D flow MRI blood flow rate assessments in major cerebral arteries, with high‐resolution 2D PCMRI as a reference.Study Type: Prospective.Subjects: Thirty‐five subjects (20 women, 79 ± 5 years, range 70–91 years).Field Strength/Sequence: 4D flow MRI with PC‐VIPR and 2D PCMRI acquired with a 3 T scanner.Assessment: We compared blood flow rates measured with 4D flow MRI, to the reference, in nine main cerebral arteries. Lumen segmentation in the 4D flow MRI was performed with k‐means clustering using four different input datasets, and with two types of thresholding methods. The threshold was defined as a percentage of the maximum intensity value in the complex difference image. Local and global thresholding approaches were used, with evaluated thresholds from 6–26%.Statistical Tests: Paired t‐test, F‐test, linear correlation (P < 0.05 was considered significant) along with intraclass correlation (ICC).Results: With the thresholding methods, the lowest average flow difference was obtained for 20% local (0.02 ± 15.0 ml/min, ICC = 0.97, n = 310) or 10% global (0.08 ± 17.3 ml/min, ICC = 0.97, n = 310) thresholding with a significant lower standard deviation for local (F‐test, P = 0.01). For all clustering methods, we found a large systematic underestimation of flow compared with 2D PCMRI (16.1–22.3 ml/min).Data Conclusion: A locally adapted threshold value gives a more stable result compared with a globally fixed threshold. 4D flow with the proposed segmentation method has the potential to become a useful reliable clinical tool for assessment of blood flow in the major cerebral arteries.Level of Evidence: 2Technical Efficacy: Stage 2
  •  
9.
  • Fredriksson, Alexandru Grigorescu, et al. (författare)
  • 4D flow MRI can detect subtle right ventricular dysfunction in primary left ventricular disease.
  • 2016
  • Ingår i: Journal of Magnetic Resonance Imaging. - : Wiley-Blackwell. - 1053-1807 .- 1522-2586. ; 43:3, s. 558-565
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To investigate whether 4D flow magnetic resonance imaging (MRI) can detect subtle right ventricular (RV) dysfunction in primary left ventricular (LV) disease.MATERIALS AND METHODS: 4D flow and morphological 3T MRI data were acquired in 22 patients with mild ischemic heart disease who were stratified into two groups based on LV end-diastolic volume index (EDVI): lower-LVEDVI and higher-LVEDVI, as well as in 11 healthy controls. The RV volume was segmented at end-diastole (ED) and end-systole (ES). Pathlines were emitted from the ED volume and traced forwards and backwards in time to ES. The blood volume was separated into flow components. The Direct Flow (DF) component was defined as RV inflow passing directly to outflow. The kinetic energy (KE) of the DF component was calculated. Echocardiographic conventional RV indices were also assessed.RESULTS: The higher-LVEDVI group had larger LVEDVI and lower LV ejection fraction (98 ± 32 ml/m(2) ; 48 ± 13%) compared to the healthy (67 ± 12, P = 0.002; 64 ± 7, P < 0.001) and lower-LVEDI groups (62 ± 10; 68 ± 7, both P < 0.001). The RV 4D flow-specific measures "DF/EDV volume-ratio" and "DF/EDV KE-ratio at ED" were lower in the higher-LVEDVI group (38 ± 5%; 52 ± 6%) compared to the healthy (44 ± 6; 65 ± 7, P = 0.018 and P < 0.001) and lower-LVEDVI groups (44 ± 6; 64 ± 7, P = 0.011 and P < 0.001). There was no difference in any of the conventional MRI and echocardiographic RV indices between the three groups.CONCLUSION: We found that in primary LV disease mild impairment of RV function can be detected by 4D flow-specific measures, but not by the conventional MRI and echocardiographic indices. J. Magn. Reson. Imaging 2015.
  •  
10.
  • Fredriksson, Alexandru Grigorescu, et al. (författare)
  • Turbulent kinetic energy in the right ventricle : Potential MR marker for risk stratification of adults with repaired Tetralogy of Fallot
  • 2018
  • Ingår i: Journal of Magnetic Resonance Imaging. - Hoboken : John Wiley & Sons. - 1053-1807 .- 1522-2586. ; 47:4, s. 1043-1053
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To assess right ventricular (RV) turbulent kinetic energy (TKE) in patients with repaired Tetralogy of Fallot (rToF) and a spectrum of pulmonary regurgitation (PR), as well as to investigate the relationship between these 4D flow markers and RV remodeling.Materials and Methods: Seventeen patients with rToF and 10 healthy controls were included in the study. Patients were divided into two groups based on PR fraction: one lower PR fraction group (11%) and one higher PR fraction group (>11%). Field strength/sequences: 3D cine phase contrast (4D flow), 2D cine phase contrast (2D flow), and balanced steady-state free precession (bSSFP) at 1.5T. Assessment: The RV volume was segmented in the morphologic short-axis images and TKE parameters were computed inside the segmented RV volume throughout diastole. Statistical tests: One-way analysis of variance with Bonferroni post-hoc test; unpaired t-test; Pearson correlation coefficients; simple and stepwise multiple regression models; intraclass correlation coefficient (ICC).Results: The higher PR fraction group had more remodeled RVs (140 6 25 vs. 107 6 22 [lower PR fraction, P < 0.01] and 93 6 15 ml/m2[healthy, P < 0.001] for RV end-diastolic volume index [RVEDVI]) and higher TKE values (5.95 6 3.15 vs. 2.23 6 0.81 [lower PR fraction, P < 0.01] and 1.91 6 0.78 mJ [healthy, P < 0.001] for Peak Total RV TKE). Multiple regression analysis between RVEDVI and 4D/2D flow parameters showed that Peak Total RV TKE was the strongest predictor of RVEDVI (R25 0.47, P 5 0.002).Conclusion: The 4D flow-specific TKE markers showed a slightly stronger association with RV remodeling than conventional 2D flow PR parameters. These results suggest novel hemodynamic aspects of PR in the development of late complications after ToF repair.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 35
Typ av publikation
tidskriftsartikel (33)
forskningsöversikt (2)
Typ av innehåll
refereegranskat (35)
Författare/redaktör
Romu, Thobias (5)
Dahlqvist Leinhard, ... (5)
Borga, Magnus (4)
Engvall, Jan (3)
Knutsson, Linda (3)
Dahlqvist Leinhard, ... (2)
visa fler...
Karlsson, Anette (2)
Kechagias, Stergios (2)
Lundberg, Peter (2)
Eklund, Anders (2)
Carlsson, Marcus (2)
Skare, S (2)
Arheden, Håkan (2)
Smedby, Örjan, 1956- (1)
Diaz, Sandra (1)
Zackrisson, Sophia (1)
Wollmer, Per (1)
Alehagen, Urban (1)
Ahlström, Håkan (1)
Ahlström, Håkan, 195 ... (1)
Ekstedt, Mattias (1)
Olsson, M. (1)
Sundgren, Pia (1)
Björkman, Anders (1)
Svensson, Jonas (1)
Ladjevardi, Sam (1)
Ekberg, Olle (1)
Persson, Anders (1)
Johansson, Martin (1)
Kits, A (1)
Sprenger, T (1)
Delgado, AF (1)
Lagerstrand, Kerstin ... (1)
Ohlsson, Bodil (1)
Wassberg, Cecilia (1)
Ahlgren, André (1)
Wirestam, Ronnie (1)
Lind, Emelie (1)
Ståhlberg, Freddy (1)
Nylander, Eva (1)
Kullberg, Joel, 1979 ... (1)
van Westen, Danielle (1)
Tamas, Eva (1)
Leander, Peter (1)
Mamidipalli, Adrija (1)
Sirlin, Claude B. (1)
Berglund, Johan (1)
Kaijser, M (1)
Brismar, Torkel B. (1)
Hansson, Stefan (1)
visa färre...
Lärosäte
Lunds universitet (14)
Linköpings universitet (13)
Karolinska Institutet (8)
Uppsala universitet (3)
Göteborgs universitet (2)
Umeå universitet (2)
visa fler...
Kungliga Tekniska Högskolan (1)
Chalmers tekniska högskola (1)
visa färre...
Språk
Engelska (35)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (27)
Teknik (10)
Naturvetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy