SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "((WFRF:(Murphy J)) srt2:(2000-2004)) srt2:(2004)"

Sökning: ((WFRF:(Murphy J)) srt2:(2000-2004)) > (2004)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Friedlein, Rainer, et al. (författare)
  • Role of electronic localization and charge-vibrational coupling in resonant photoelectron spectra of polymers : Application to poly(para-phenylenevinylene)
  • 2004
  • Ingår i: Physical Review B. Condensed Matter and Materials Physics. - 1098-0121 .- 1550-235X. ; 69:12
  • Tidskriftsartikel (refereegranskat)abstract
    • A combination of x-ray absorption and resonant photoemission (RPE) spectroscopy has been used to study the electronic structure of the one-dimensional conjugated polymer poly (para-phenylenevinylene) in nonordered (as prepared) thin films. The dispersion of RPE features for the decay to localized and delocalized bands are qualitatively different. A theory for band dispersion of RPE in polymers is given, showing the important roles of electronic state localization and vibrational (phonon) excitations for the character of the dispersion.
  •  
4.
  • Lee, Benjamin Y., et al. (författare)
  • Unmasking true signal/tumor information from ProstaScint scans
  • 2004
  • Ingår i: MEDICAL IMAGING 2004: IMAGE PROCESSING, PTS 1-3. - : SPIE - International Society for Optical Engineering. - 0819452831 ; , s. 1980-1990
  • Konferensbidrag (refereegranskat)abstract
    • Purpose: Improve tumor localization in In-111 ProstaScint SPECT scans through improved reconstruction and identification/removal of non-specific blood pool volumes using simultaneously acquired Tc-99m tagged red blood cell (RBC) SPECT scans. Methods: We chose 30 patients with a history of prostate cancer who had undergone CT/MR and simultaneous Tc-99m RBC/In-111 ProstaScint SPECT scans due to rising PSA. To estimate the impact of reconstruction methods on anatomic definition and artifacts, SPECT volume data sets were reconstructed using ordered set-expectation maximization (OS-EM) with varying numbers of iterations and subsets, and these were compared against each other and against standard filtered back projection (FBP) reconstruction. Non-blood pool bladder activity in the Tc-99m scans was suppressed prior to subtraction from the In-111 scans by using an averaging algorithm within an ellipsoid volume encompassing the bladder. Outside the ellipsoid volume, Tc-99m voxel values were subtracted from the corresponding In-111 voxels after normalization of the data sets based on peak activity within the descending aorta. Results: OS-EM reconstruction using 3 iterations and 45 subsets showed improved representation of anatomy compared with FBP. Bladder suppression reduced artifacts in the prostate bed. The subtraction method reduced the blood pool signal, confirmed visually by superimposition with matched CT/MR scans. Conclusions: OS-EM reconstruction together with bladder suppression and subtraction of the blood pool may help improve the specificity of ProstaScint SPECT interpretation and increase its utility in radiation therapy treatment planning.
  •  
5.
  •  
6.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy