1.
  • Roth, Daniel, et al. (författare)
  • A method for tumor dosimetry based on hybrid planar-SPECT/CT images and semiautomatic segmentation
  • 2018
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405 .- 2473-4209. ; 45:11, s. 5004-5018
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: A hybrid planar-SPECT/CT method for tumor dosimetry in 177Lu-DOTATATE therapy, applicable to datasets consisting of multiple conjugate-view images and one SPECT/CT, is developed and evaluated. Methods: The imaging protocol includes conjugate-view imaging at 1, 24, 96, and 168 h post infusion (p.i.) and a SPECT/CT acquisition 24 h p.i. The dosimetry method uses the planar images to estimate the shape of the time–activity concentration curve, which is then rescaled to absolute units using the SPECT-derived activity concentration. The resulting time-integrated activity concentration coefficient (TIACC) is used to calculate the tumor-absorbed dose. Semiautomatic segmentation techniques are applied for tumor delineation in both planar and SPECT images, where the planar image segmentation is accomplished using an active-rays-based technique. The selection of tumors is done by visual inspection of planar and SPECT images and applying a set of criteria concerning the tumor visibility and possible interference from superimposed activity uptakes in the planar images. Five different strategies for determining values from planar regions of interest (ROIs), based on entire or partial ROIs, and with and without background correction, are evaluated. Evaluation is performed against a SPECT/CT-based method on data from six patients where sequential conjugate-view and SPECT/CT imaging have been performed in parallel and against ground truths in Monte Carlo simulated images. The patient data are also used to evaluate the interoperator variability and to assess the validity of the developed criteria for tumor selection. Results: For patient images, the hybrid method produces TIACCs that are on average 6% below those of the SPECT/CT only method, with standard deviations for the relative TIACC differences of 8%–11%. Simulations show that the hybrid and SPECT-based methods estimate the TIACCs to within approximately 10% for tumors larger than around 10 ml, while for smaller tumors, all methods underestimate the TIACCs due to underestimations of the activity concentrations in the SPECT images. The planar image segmentation has a low operator dependence, with a median Dice similarity coefficient of 0.97 between operators. The adopted criteria for tumor selection manage to discriminate the tumors for which the absorbed-dose deviations between the hybrid and SPECT methods are the highest. Conclusions: The hybrid method is found suitable for studies of tumor-absorbed doses in radionuclide therapy, provided that selection criteria regarding the visibility and overlapping activities in the planar images are applied.
  •  
2.
  • Kjellsson Lindblom, Emely, et al. (författare)
  • Impact of SBRT fractionation in hypoxia dose painting - accounting for heterogeneous and dynamic tumour oxygenation
  • 2019
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 46:5, s. 2512-2521
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTumor hypoxia, often found in nonsmall cell lung cancer (NSCLC), implies an increased resistance to radiotherapy. Pretreatment assessment of tumor oxygenation is, therefore, warranted in these patients, as functional imaging of hypoxia could be used as a basis for dose painting. This study aimed at investigating the feasibility of using a method for calculating the dose required in hypoxic subvolumes segmented on 18F‐HX4 positron emission tomography (PET) imaging of NSCLC.MethodsPositron emission tomography imaging data based on the hypoxia tracer 18F‐HX4 of 19 NSCLC patients were included in the study. Normalized tracer uptake was converted to oxygen partial pressure (pO2) and hypoxic target volumes (HTVs) were segmented using a threshold of 10 mmHg. Uniform doses required to overcome the hypoxic resistance in the target volumes were calculated based on a previously proposed method taking into account the effect of interfraction reoxygenation, for fractionation schedules ranging from extremely hypofractionated stereotactic body radiotherapy (SBRT) to conventionally fractionated radiotherapy.ResultsGross target volumes ranged between 6.2 and 859.6 cm3, and the hypoxic fraction < 10 mmHg between 1.2% and 72.4%. The calculated doses for overcoming the resistance of cells in the HTVs were comparable to those currently prescribed in clinical practice as well as those previously tested in feasibility studies on dose escalation in NSCLC. Depending on the size of the HTV and the distribution of pO2, HTV doses were calculated as 43.6–48.4 Gy for a three‐fraction schedule, 51.7–57.6 Gy for five fractions, and 59.5–66.4 Gy for eight fractions. For patients in whom the HTV pO2 distribution was more favorable, a lower dose was required despite a bigger volume. Tumor control probability was lower for single‐fraction schedules, while higher levels of tumor control probability were found for schedules employing several fractions.ConclusionsThe method to account for heterogeneous and dynamic hypoxia in target volume segmentation and dose prescription based on 18F‐HX4‐PET imaging appears feasible in NSCLC patients. The distribution of oxygen partial pressure within HTV could impact the required prescribed dose more than the size of the volume.
  •  
3.
  • Ödén, Jakob, et al. (författare)
  • Inclusion of a variable RBE into proton and photon plan comparison for various fractionation schedules in prostate radiation therapy
  • 2017
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405 .- 2473-4209. ; 44:3, s. 810-822
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: A constant relative biological effectiveness (RBE) of 1.1 is currently used in proton radiation therapy to account for the increased biological effectiveness compared to photon therapy. However, there is increasing evidence that proton RBE vary with the linear energy transfer (LET), the dose per fraction and the type of the tissue. Therefore, this study aims to evaluate the impact of disregarding variations in RBE when comparing proton and photon dose plans for prostate treatments for various fractionation schedules using published RBE models and several α/β assumptions.Methods: Photon and proton dose plans were created for three generic prostate cancer cases. Three BED3Gy equivalent schedules were studied, 78, 57.2 and 42.8 Gy in 39, 15 and 7 fractions, respectively. The proton plans were optimized assuming a constant RBE of 1.1. By using the Monte Carlo calculated dose-averaged LET (LETd) distribution and assuming α/β values on voxel level, three variable RBE models were applied to the proton dose plans. The impact of the variable RBE was studied in the plan comparison, which was based on the dose distribution, DVHs and normal tissue complication probabilities (NTCP) for the rectum. Subsequently, the physical proton dose was re-optimized for each proton plan based on the LETd distribution, to achieve a homogeneous RBE weighted target dose when applying a specific RBE model and still fulfil the clinical goals for the rectum and bladder.Results: All the photon and proton plans assuming RBE=1.1 met the clinical goals with similar target coverage. The proton plans fulfilled the robustness criteria in terms of range and setup uncertainty. Applying the variable RBE models generally resulted in higher target doses and rectum NTCP compared to the photon plans. The increase was most pronounced for the fractionation dose of 2 Gy(RBE) whereas it was of less magnitude and more dependent on model and α/β assumption for the hypofractionated schedules. The re-optimized proton plans proved to be robust and showed similar target coverage and doses to the organs at risk as the proton plans optimized with a constant RBE.Conclusions: Model predicted RBE values may differ substantially from 1.1. This is most pronounced for fractionation doses of around 2 Gy(RBE) with higher doses to the target and the OARs, whereas the effect seems to be of less importance for the hypofractionated schedules. This could result in misleading conclusions when comparing proton plans to photon plans. By accounting for a variable RBE in the optimization process, robust and clinically acceptable dose plans, with the potential of lowering rectal NTCP, may be generated by re-optimizing the physical dose. However, the direction and magnitude of the changes in the physical proton dose to the prostate are dependent on RBE model and α/β assumptions and should therefore be used conservatively.
  •  
4.
  • Morén, Björn, 1987-, et al. (författare)
  • An extended dose-volume model in high dose-rate brachytherapy : Using mean-tail-dose to reduce tumor underdosage
  • 2019
  • Ingår i: Medical physics (Lancaster). - : Wiley-Blackwell Publishing Inc.. - 0094-2405 .- 2473-4209. ; 46:6, s. 2556-2566
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose High dose-rate brachytherapy is a method of radiotherapy for cancer treatment in which the radiation source is placed within the body. In addition to give a high enough dose to a tumor, it is also important to spare nearby healthy organs [organs at risk (OAR)]. Dose plans are commonly evaluated using the so-called dosimetric indices; for the tumor, the portion of the structure that receives a sufficiently high dose is calculated, while for OAR it is instead the portion of the structure that receives a sufficiently low dose that is of interest. Models that include dosimetric indices are referred to as dose-volume models (DVMs) and have received much interest recently. Such models do not take the dose to the coldest (least irradiated) volume of the tumor into account, which is a distinct weakness since research indicates that the treatment effect can be largely impaired by tumor underdosage even to small volumes. Therefore, our aim is to extend a DVM to also consider the dose to the coldest volume. Methods An improved DVM for dose planning is proposed. In addition to optimizing with respect to dosimetric indices, this model also takes mean dose to the coldest volume of the tumor into account. Results Our extended model has been evaluated against a standard DVM in ten prostate geometries. Our results show that the dose to the coldest volume could be increased, while also computing times for the dose planning were improved. Conclusion While the proposed model yields dose plans similar to other models in most aspects, it fulfils its purpose of increasing the dose to cold tumor volumes. An additional benefit is shorter solution times, and especially for clinically relevant times (of minutes) we show major improvements in tumour dosimetric indices.
  •  
5.
  • Vilhelmsson Timmermand, Oskar, et al. (författare)
  • High resolution digital autoradiographic and dosimetric analysis of heterogeneous radioactivity distribution in xenografted prostate tumors
  • 2016
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 43:12, s. 6632-6643
  • Tidskriftsartikel (refereegranskat)abstract
    • The first main aim of this study was to illustrate the absorbed dose rate distribution from 177Lu in sections of xenografted prostate cancer (PCa) tumors using high resolution digital autoradiography (DAR) and compare it with hypothetical identical radioactivity distributions of 90Y or 7 MeV alpha-particles. Three dosimetry models based on either dose point kernels or Monte Carlo simulations were used and evaluated. The second and overlapping aim, was to perform DAR imaging and dosimetric analysis of the distribution of radioactivity, and hence the absorbed dose rate, in tumor sections at an early time point after injection during radioimmunotherapy using 177Lu-h11B6, directed against the human kallikrein 2 antigen.
  •  
6.
  • Andersson, Jonas, 1975-, et al. (författare)
  • Modeling ion recombination in liquid ionization chambers : Improvement and analysis of the two-dose-rate method
  • 2017
  • Ingår i: Medical physics (Lancaster). - : John Wiley & Sons. - 0094-2405. ; 44:11, s. 5977-5987
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The use of liquid ionization chambers can provide useful information to endeavors with radiation dosimetry for highly modulated beams. Liquid ionization chambers may be particularly suitable for computed tomography applications where conventional ionization chambers do not present a high enough sensitivity for the spatial resolution required to characterize common X-ray beams. Due to the sensitivity, which leads to high charge densities, liquid ionization chambers can suffer from large recombination losses leading to degradation in signal to dose rate linearity. To solve this problem, a two-dose-rate method for general recombination correction has been proposed for liquid ionization chambers. However, the valid range of recombination losses that the method can accurately account for has been found to vary depending on radiation quality. The present work provides an in-depth analysis of the performance of the two-dose-rate method. Furthermore, the soundness of applying gas theory to liquids is investigated by using the two-dose-rate method.Methods: In the present work, the two-dose-rate method for general recombination correction of liquid ionization chambers used in continuous beams is studied by employing theory for gas-filled ionization chambers. An approximate relation for the general collection efficiency containing a material-specific parameter that is traceable to liquids has been derived for theoretical and experimental investigation alongside existing theory. Furthermore, the disassociation between initial and general recombination in the method is analyzed both theoretically and experimentally.Results: The results indicate that liquids and gases share general recombination characteristics, where the liquids investigated (isooctane and tetramethylsilane) to a large extent mimic the behavior theoretically expected in gases. Furthermore, it is shown that the disassociation between initial and general recombination in the two-dose-rate method is an approximation that depends on the relation between initial recombination and the collecting electric field strength at the dose rates used.Conclusions: Due to the approximation used to separate initial and general recombination the valid range of collection efficiencies for the two-dose-rate method will not only depend on the model used to describe general recombination but also on the type of liquid and radiation beam quality. As there is no robust theory for initial recombination in liquids to apply, the valid range of general collection efficiencies for the two-dose-rate method should be experimentally evaluated for each radiation dosimetry application.
  •  
7.
  • Dewaraja, Yuni K., et al. (författare)
  • Improved quantitative 90Y bremsstrahlung SPECT/CT reconstruction with Monte Carlo scatter modeling
  • 2017
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 44:12, s. 6364-6376
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: In 90Y microsphere radioembolization (RE), accurate post-therapy imaging-based dosimetry is important for establishing absorbed dose versus outcome relationships for developing future treatment planning strategies. Additionally, accurately assessing microsphere distributions is important because of concerns for unexpected activity deposition outside the liver. Quantitative 90Y imaging by either SPECT or PET is challenging. In 90Y SPECT model based methods are necessary for scatter correction because energy window-based methods are not feasible with the continuous bremsstrahlung energy spectrum. The objective of this work was to implement and evaluate a scatter estimation method for accurate 90Y bremsstrahlung SPECT/CT imaging. Methods: Since a fully Monte Carlo (MC) approach to 90Y SPECT reconstruction is computationally very demanding, in the present study the scatter estimate generated by a MC simulator was combined with an analytical projector in the 3D OS-EM reconstruction model. A single window (105 to 195-keV) was used for both the acquisition and the projector modeling. A liver/lung torso phantom with intrahepatic lesions and low-uptake extrahepatic objects was imaged to evaluate SPECT/CT reconstruction without and with scatter correction. Clinical application was demonstrated by applying the reconstruction approach to five patients treated with RE to determine lesion and normal liver activity concentrations using a (liver) relative calibration. Results: There was convergence of the scatter estimate after just two updates, greatly reducing computational requirements. In the phantom study, compared with reconstruction without scatter correction, with MC scatter modeling there was substantial improvement in activity recovery in intrahepatic lesions (from > 55% to > 86%), normal liver (from 113% to 104%), and lungs (from 227% to 104%) with only a small degradation in noise (13% vs. 17%). Similarly, with scatter modeling contrast improved substantially both visually and in terms of a detectability index, which was especially relevant for the low uptake extrahepatic objects. The trends observed for the phantom were also seen in the patient studies where lesion activity concentrations and lesion-to-liver concentration ratios were lower for SPECT without scatter correction compared with reconstruction with just two MC scatter updates: in eleven lesions the mean uptake was 4.9 vs. 7.1 MBq/mL (P = 0.0547), the mean normal liver uptake was 1.6 vs. 1.5 MBq/mL (P = 0.056) and the mean lesion-to-liver uptake ratio was 2.7 vs. 4.3 (P = 0.0402) for reconstruction without and with scatter correction respectively. Conclusions: Quantitative accuracy of 90Y bremsstrahlung imaging can be substantially improved with MC scatter modeling without significant degradation in image noise or intensive computational requirements.
  •  
8.
  • Källman, Hans-Erik, et al. (författare)
  • Source modeling for Monte Carlo dose calculation of CT examinations with a radiotherapy treatment planning system
  • 2016
  • Ingår i: Medical physics (Lancaster). - : Wiley. - 0094-2405. ; 43:11, s. 6118-6128
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose:Radiation dose to patients undergoing examinations with Multislice Computed Tomography (MSCT) as well as Cone Beam Computed Tomography (CBCT) is a matter of concern. Risk management could benefit from efficient replace rational dose calculation tools. The paper aims to verify MSCT dose calculations using a Treatment Planning System (TPS) for radiotherapy and to evaluate four different variations of bow-tie filter characterizations for the beam model used in the dose calculations.Methods:A TPS (RayStation™, RaySearch Laboratories, Stockholm, Sweden) was configured to calculate dose from a MSCT (GE Healthcare, Wauwatosa, WI, USA). The x-ray beam was characterized in a stationary position the by measurements of the Half-Value Layer (HVL) in aluminum and kerma along the principal axes of the isocenter plane perpendicular to the beam. A Monte Carlo source model for the dose calculation was applied with four different variations on the beam-shaping bow-tie filter, taking into account the different degrees of HVL information but reconstructing the measured kerma distribution after the bow-tie filter by adjusting the photon sampling function. The resulting dose calculations were verified by comparison with measurements in solid water as well as in an anthropomorphic phantom.Results:The calculated depth dose in solid water as well as the relative dose profiles was in agreement with the corresponding measured values. Doses calculated in the anthropomorphic phantom in the range 26–55 mGy agreed with the corresponding thermo luminescence dosimeter (TLD) measurements. Deviations between measurements and calculations were of the order of the measurement uncertainties. There was no significant difference between the different variations on the bow-tie filter modeling.Conclusions:Under the assumption that the calculated kerma after the bow-tie filter replicates the measured kerma, the central specification of the HVL of the x-ray beam together with the kerma distribution can be used to characterize the beam. Thus, within the limits of the study, a flat bow-tie filter with an HVL specified by the vendor suffices to calculate the dose distribution. The TPS could be successfully configured to replicate the beam movement and intensity modulation of a spiral scan with dose modulation, on the basis of the specifications available in the metadata of the digital images and the log file of the CT.
  •  
9.
  • MINGUEZ GABINA, PABLO, et al. (författare)
  • Whole-remnant and maximum-voxel SPECT/CT dosimetry in 131I-NaI treatments of differentiated thyroid cancer
  • 2016
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 43:10, s. 5279-5287
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To investigate the possible differences between SPECT/CT based whole-remnant and maximum-voxel dosimetry in patients receiving radio-iodine ablation treatment of differentiated thyroid cancer (DTC). Methods: Eighteen DTC patients were administered 1.11 GBq of 131I-NaI after near-total thyroidectomy and rhTSH stimulation. Two patients had two remnants, so in total dosimetry was performed for 20 sites. Three SPECT/CT scans were performed for each patient at 1, 2, and 3-7 days after administration. The activity, the remnant mass, and the maximum-voxel activity were determined from these images and from a recovery-coefficient curve derived from experimental phantom measurements. The cumulated activity was estimated using trapezoidal-exponential integration. Finally, the absorbed dose was calculated using S-values for unit-density spheres in whole-remnant dosimetry and S-values for voxels in maximum-voxel dosimetry. Results: The mean absorbed dose obtained from whole-remnant dosimetry was 40 Gy (range 2-176 Gy) and from maximum-voxel dosimetry 34 Gy (range 2-145 Gy). For any given patient, the activity concentrations for each of the three time-points were approximately the same for the two methods. The effective half-lives varied (R = 0.865), mainly due to discrepancies in estimation of the longer effective half-lives. On average, absorbed doses obtained from whole-remnant dosimetry were 1.2±0.2 (1 SD) higher than for maximum-voxel dosimetry, mainly due to differences in the S-values. The method-related differences were however small in comparison to the wide range of absorbed doses obtained in patients. Conclusions: Simple and consistent procedures for SPECT/CT based whole-volume and maximumvoxel dosimetry have been described, both based on experimentally determined recovery coefficients. Generally the results from the two approaches are consistent, although there is a small, systematic difference in the absorbed dose due to differences in the S-values, and some variability due to differences in the estimated effective half-lives, especially when the effective half-life is long. Irrespective of the method used, the patient absorbed doses obtained span over two orders of magnitude.
  •  
10.
  • Pacilio, Massimiliano, et al. (författare)
  • Impact of SPECT corrections on 3D-dosimetry for liver transarterial radioembolization using the patient relative calibration methodology
  • 2016
  • Ingår i: Medical Physics. - : Wiley. - 0094-2405. ; 43:7, s. 4053-4064
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Many centers aim to plan liver transarterial radioembolization (TARE) with dosimetry, even without CT-based attenuation correction (AC), or with unoptimized scatter correction (SC) methods. This work investigates the impact of presence vs absence of such corrections, and limited spatial resolution, on 3D dosimetry for TARE. Methods: Three voxelized phantoms were derived from CT images of real patients with different body sizes. Simulations of 99mTc-SPECT projections were performed with the SIMIND code, assuming three activity distributions in the liver: uniform, inside a "liver's segment," or distributing multiple uptaking nodules ("nonuniform liver"), with a tumoral liver/healthy parenchyma ratio of 5:1. Projection data were reconstructed by a commercial workstation, with OSEM protocol not specifically optimized for dosimetry (spatial resolution of 12.6 mm), with/without SC (optimized, or with parameters predefined by the manufacturer; dual energy window), and with/without AC. Activity in voxels was calculated by a relative calibration, assuming identical microspheres and 99mTc-SPECT counts spatial distribution. 3D dose distributions were calculated by convolution with 90Y voxel S-values, assuming permanent trapping of microspheres. Cumulative dose-volume histograms in lesions and healthy parenchyma from different reconstructions were compared with those obtained from the reference biodistribution (the "gold standard," GS), assessing differences for D95%, D70%, and D50% (i.e., minimum value of the absorbed dose to a percentage of the irradiated volume). γ tool analysis with tolerance of 3%/13 mm was used to evaluate the agreement between GS and simulated cases. The influence of deep-breathing was studied, blurring the reference biodistributions with a 3D anisotropic gaussian kernel, and performing the simulations once again. Results: Differences of the dosimetric indicators were noticeable in some cases, always negative for lesions and distributed around zero for parenchyma. Application of AC and SC reduced systematically the differences for lesions by 5%-14% for a liver segment, and by 7%-12% for a nonuniform liver. For parenchyma, the data trend was less clear, but the overall range of variability passed from -10%/40% for a liver segment, and -10%/20% for a nonuniform liver, to -13%/6% in both cases. Applying AC, SC with preset parameters gave similar results to optimized SC, as confirmed by γ tool analysis. Moreover, γ analysis confirmed that solely AC and SC are not sufficient to obtain accurate 3D dose distribution. With breathing, the accuracy worsened severely for all dosimetric indicators, above all for lesions: with AC and optimized SC, -38%/-13% in liver's segment, -61%/-40% in the nonuniform liver. For parenchyma, D50% resulted always less sensitive to breathing and sub-optimal correction methods (difference overall range: -7%/13%). Conclusions: Reconstruction protocol optimization, AC, SC, PVE and respiratory motion corrections should be implemented to obtain the best possible dosimetric accuracy. On the other side, thanks to the relative calibration, D50% inaccuracy for the healthy parenchyma from absence of AC was less than expected, while the optimization of SC was scarcely influent. The relative calibration therefore allows to perform TARE planning, basing on D50% for the healthy parenchyma, even without AC or with suboptimal corrections, rather than rely on nondosimetric methods.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 10
Typ av publikation
tidskriftsartikel (10)
Typ av innehåll
refereegranskat (10)
Författare/redaktör
Ljungberg, Michael (2)
Toma-Daşu, Iuliana (2)
Andersson, Jonas, 19 ... (2)
Sjögreen Gleisner, K ... (2)
Eriksson, Kjell (1)
Carlsson Tedgren, Ås ... (1)
visa fler...
Strand, Sven-Erik (1)
Nilsson, Jenny (1)
Ahnesjö, Anders (1)
Traneus, Erik (1)
Gustafsson, Johan (1)
Cremonesi, Marta (1)
Elgqvist, Jörgen, 19 ... (1)
Tölli, Heikki (1)
Holmberg, Rickard (1)
Dasu, Alexandru (1)
Wersäll, Peter (1)
Ureba, Ana (1)
Flux, Glenn (1)
Pani, Roberto (1)
Kull, Love (1)
Sundlöv, Anna (1)
Dewaraja, Yuni K. (1)
Chun, Se Young (1)
Srinivasa, Ravi N. (1)
Kaza, Ravi K. (1)
Cuneo, Kyle C. (1)
Majdalany, Bill S. (1)
Novelli, Paula M. (1)
Fessler, Jeffrey A. (1)
Larsson, Torbjörn, 1 ... (1)
Vilhelmsson Timmerma ... (1)
Chiesa, Carlo (1)
Rodeño, Emilia (1)
Ödén, Jakob (1)
Roth, Daniel (1)
Kjellsson Lindblom, ... (1)
Even, Aniek J. G. (1)
van Elmpt, Wouter (1)
Lambin, Philippe (1)
Källman, Hans-Erik (1)
Delgado, Alejandro (1)
Mínguez Gabiña, Pabl ... (1)
Genolla, Jose (1)
Morén, Björn, 1987- (1)
Pacilio, Massimilian ... (1)
Ferrari, Mahila (1)
Lorenzon, Leda (1)
Mira, Marta (1)
Botta, Francesca (1)
visa färre...
Lärosäte
Lunds universitet (5)
Karolinska Institutet (3)
Umeå universitet (2)
Uppsala universitet (2)
Stockholms universitet (2)
Göteborgs universitet (1)
visa fler...
Linköpings universitet (1)
visa färre...
Språk
Engelska (10)
Forskningsämne (UKÄ/SCB)
Naturvetenskap (10)
Medicin och hälsovetenskap (10)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy