SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(L773:0105 1873) pers:(Mowitz Martin) srt2:(2020-2024)"

Sökning: (L773:0105 1873) pers:(Mowitz Martin) > (2020-2024)

  • Resultat 1-10 av 23
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alves da Silva, Catarina, et al. (författare)
  • Contact dermatitis in children caused by diabetes devices
  • 2022
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 87:5, s. 406-413
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Insulin pumps and glucose monitoring devices improve diabetes mellitus control and enhance patients' quality of life. However, a growing number of adverse cutaneous reactions related to the use of these devices have been reported. Objective: To investigate the culprits of localized contact dermatitis in paediatric patients with diabetes caused by insulin pumps and glucose monitoring devices. Methods: Retrospective analysis of 15 paediatric patients patch tested as part of a clinical investigation for skin reactions associated with insulin pumps and glucose monitoring devices. Results: Seven patients had positive patch test reactions to isobornyl acrylate (IBOA) and five had positive reactions to benzoyl peroxide (BP). Positive patch test reactions to materials from the glucose sensor and/or insulin pump were seen in 10 of the 15 patients. Three had positive reactions to adhesive remover wipe from Smith and Nephew Remove and four had reactions to EMLA plaster. Conclusion: A high share of patients showed positive reactions to IBOA and/or their medical devices (insulin pumps or glucose devices). A third of patients showed positive reactions to BP. The presence of additional unidentified allergens cannot be excluded, highlighting the importance of access to a full description of the chemical composition of the devices.
  •  
2.
  • Antelmi, Annarita, et al. (författare)
  • 4,4′-Thiobis(2-tert-butyl-5-methylphenol), an antioxidant in medical devices that may cause allergic contact dermatitis
  • 2023
  • Ingår i: Contact Dermatitis. - 0105-1873. ; 89:2, s. 103-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Antioxidants in medical devices, added to protect polymers or adhesives, may also cause contact dermatitis in some individuals. Objectives: To present data on sensitization to 4,4′-thiobis(2-tert-butyl-5-methylphenol), an antioxidant detected in some types of medical devices, for six patients that experienced eczematous reactions to different medical devices. Methods: Patch testing with 4,4′-thiobis(2-tert-butyl-5-methylphenol), 1% pet was performed. Gas chromatography-mass spectrometry (GC-MS) was used for identification of 4,4′-thiobis(2-tert-butyl-5-methylphenol) in different medical device products. Results: Six patients with contact allergy to 4,4′-thiobis(2-tert-butyl-5-methylphenol) also had relevant contact allergic reactions to medical devices containing the antioxidant. The presence of the antioxidant in products was detected using GC-MS analysis. Conclusions: The antioxidant 4,4′-thiobis(2-tert-butyl-5-methylphenol) may cause allergic contact dermatitis after exposure to different medical devices.
  •  
3.
  •  
4.
  • Bruze, Magnus, et al. (författare)
  • Contact allergy to oxidised geraniol may be over-represented in individuals with photocontact allergy to ketoprofen
  • 2024
  • Ingår i: Contact Dermatitis. - 0105-1873. ; 90:1, s. 79-83
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Simultaneous overrepresentations of contact allergies and photocontact allergies are common in individuals with photocontact allergy to ketoprofen. Aims: To investigate whether contact allergy to oxidised (ox.) geraniol, geraniol, geranial, neral and citral is overrepresented in individuals with photocontact allergy to ketoprofen. Methods: The contact allergy rates to ox. geraniol, geraniol, geranial, neral and citral in routinely patch tested dermatitis patients were compared with the corresponding rates in individuals with photocontact allergy to ketoprofen. Results: Allergic patch test reactions were noted to ox. geraniol 11% (n = 39, 5.8%), ox. geraniol 6% (n = 12, 1.8%), geraniol 6% (n = 2, 0.3%), geranial (n = 18, 2.7%), neral (n = 7, 1.0%) and citral (n = 15, 2.2%). In those four patients who were diagnosed with photocontact allergy to ketoprofen during the test period, a significant overrepresentation (p = 0.020) of simultaneous contact allergy to ox. geraniol 11% was demonstrated. Overrepresentation of simultaneous contact allergy to various combinations of ox. geraniol, ox. limonene and ox. linalool was also noted in ketoprofen-photoallergic patients. Conclusions: Contact allergy to ox. geraniol, geranial and citral is common in routinely tested dermatitis patients. There is an overrepresentation of simultaneous contact allergy to ox. geraniol, ox. limonene and ox. linalool in patients with photocontact allergy to ketoprofen.
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  • Gatica-Ortega, María Elena, et al. (författare)
  • Contact dermatitis from glucose sensors in Spain : A multicentric approach
  • 2021
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 85:5, s. 554-562
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Allergic contact dermatitis from glucose sensors may interfere with their ongoing application. Objective: To evaluate a series of Spanish patients with contact dermatitis to glucose sensors regarding former sources of contact allergens, patch test results, and outcomes from the ongoing use of the device. Methods: A series of patients with contact dermatitis from glucose sensors was investigated in eight dermatology departments across Spain (epidemiological features, brands, latency time to develop dermatitis, the ability to continue using the devices as well as the patch test results). Results: Thirty patients were evaluated (mean age 20.9 years). A total of 66.7% were children and 66.7% female. Ninety per cent used Freestyle Libre (FSL). Eight of 26 (30.8%) reacted to isobornyl acrylate (IBOA) and two of 20 (10.0%) to N,N dimethylacrylamide (DMAA). The mean latency time to develop dermatitis was 9 months. Sixteen of 29 (55.2%) patients continued using the same sensor causing the reaction. Thirteen of 29 (44.8%) patients were unable to continue using the sensor because of severe reactions. Of these, five were positive to IBOA, one to IBOA and DMAA, one to DMAA, one to colophony, and one to isopropyl alcohol wipes. In one patient, the outcome was unknown. Conclusion: The frequency of sensitisation to IBOA and DMAA, was lower than in other European series, but similar to a previously published Spanish article. Legislation requiring manufacturers to provide information regarding the composition of medical devices and cooperate with the investigations into contact dermatitis is urgently needed.
  •  
9.
  •  
10.
  • Herreros-Montejano, Francisca, et al. (författare)
  • Outbreak of occupational allergic contact dermatitis from a smartphone screen protector glue
  • 2022
  • Ingår i: Contact Dermatitis. - : Wiley. - 0105-1873 .- 1600-0536. ; 87:1, s. 53-61
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Sensitization to acrylates is a concern in the occupational/environmental dermatology field. Objective: To describe an occupational allergic contact dermatitis (ACD) outbreak from a smartphone screen protector glue. Methods: Thirteen affected workers of a chain store selling phone screen protectors were investigated in five Spanish dermatology departments. The glue datasheet and label were assessed. A chemical analysis of the glue was performed. Based on this, some patients underwent additional testing. Results: All patients (all female, mean age: 25) had severe fingertip dermatitis. The datasheet/label indicated that the glue contained isobornyl acrylate (IBOA), a “photoinitiator” and polyurethane oligomer. The company informed us that the ingredients were polyurethane acrylate, “methacrylate” (unspecified), acrylic acid, hydroxyethyl methacrylate, propylmethoxy siloxane, and photoinitiator 184. Isobornyl acrylate (or IBOA) and N,N-dimethylacrylamide (DMAA) were patch tested in eight and two cases, respectively, with negative results. A chemical analysis revealed 4-acryloylmorpholine (ACMO); isobornyl methacrylate (IBMA), and lauryl acrylate in one glue sample. Seven patients were patch tested with dilutions of the identified substances and six of seven were positive for ACMO 0.5% pet. Conclusion: An outbreak of occupational ACD, likely from ACMO in a glue is described. Further investigations are needed to corroborate the role played by each compound identified in the chemical analyses.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 23

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy