SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(L773:0142 9612 OR L773:1878 5905) srt2:(1995-1999)"

Sökning: (L773:0142 9612 OR L773:1878 5905) > (1995-1999)

  • Resultat 1-10 av 18
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Freij-Larsson, Christina, et al. (författare)
  • Adsorption behaviour of amphiphilic polymers at hydrophobic surfaces: Effects on protein adsorption
  • 1996
  • Ingår i: Biomaterials. - : Elsevier BV. - 1878-5905 .- 0142-9612. ; 17:22, s. 2199-2207
  • Tidskriftsartikel (refereegranskat)abstract
    • The adsorption of four different amphiphilic polymers to a model surface has been studied, and the effects of the adsorbed amphiphiles on the subsequent adsorption of fibrinogen (Fg) and human serum albumin (HSA) at the surfaces were investigated. The amphiphilic polymers were one commercially available ABA block copolymer, Pluronic PE9400 (PE94), composed of poly(ethylene oxide) (A-blocks) and poly(propylene oxide) (B-block), and three graft copolymers, two with backbones of poly(styrene-co-acrylamide) (STY) and one with a backbone of poly(methyl methacrylate-co-ethylhexyl methacrylate) (ACRY). The backbones carried poly(ethylene oxide) (PEG) grafts, The model surface was a hydrophobic methylated silica surface (HMS). The amphiphilic polymers were adsorbed at the HMS surface from an ethanol/water solution. The adsorption process was monitored by ellipsometry. After rinsing with phosphate buffered saline (PBS), protein was added and the continued adsorption measured by ellipsometry. Surfaces modified by adsorption of the amphiphilic polymers were also characterized by contact angle measurements and X-ray photoelectron spectroscopy (XPS). According to these measurements the amphiphilic polymers adsorbed in significant amounts at the HMS surface. A limited study by atomic force microscopy (AFM), as well as the XPS measurements, suggests that both single molecules and micellar aggregates adsorb at the surface. ACRY and PE94 gave the highest levels of adsorption. As compared to the Pluronic block copolymer the graft copolymers were more strongly attached to the HMS surface, as shown by less desorption on rinsing with solvent. The ellipsometric results show that the adsorption of HSA and Fg at HMS surfaces containing preadsorbed amphiphilic polymer was significantly reduced as compared to the bare HMS surface. ACRY and PE94 showed the largest effects. Both polymers gave more than a 20-fold reduction of the Fg adsorption and a 10-fold reduction of the HSA adsorption. The STY polymers reduced the protein adsorption by a factor of 2-3.
  •  
2.
  • Zhang, Y Z, et al. (författare)
  • Tissue response to commercial silicone and polyurethane elastomers after different sterilization procedures
  • 1996
  • Ingår i: Biomaterials. - : Elsevier BV. - 1878-5905 .- 0142-9612. ; 17:23, s. 2265-2272
  • Tidskriftsartikel (refereegranskat)abstract
    • Two different commercial polymeric materials, a silicone and a polyurethane (PUR), were studied with regard to correlations between the chemical and physical compositions of the polymer surfaces and the biological response on implantation. Test specimens of the materials were manufactured according to standard procedures. The specimens were implanted in rats for 10 and 90 days. Before implantation the polymers were sterilized in three different ways, namely, beta irradiation, ethylene oxide sterilization and steam sterilization. The polymers were characterized before and after the implantation with respect to the chemical composition and the morphology of the surfaces. After implantation the biological response was evaluated by counting numbers of macrophages, giant cells, fibroblasts and other cells present at the surfaces. The thickness of the fibrous capsule surrounding the test specimens was measured at the thickest and thinnest parts. PUR surfaces showed signs of degradation already after sterilization and after 10 to 90 days of implantation, pits and cracks appeared, especially in the ethylene oxide sterilized samples. However, differences in the biological responses were small and independent of the sterilization method. After 10 days of implantation the capsule thickness and the amounts of cell material adhering at the surfaces were different, and it appears that the silicone rubber induces more tissue response than PUR. The differences in the early tissue response evened out after 90 days implantation time and a steady state situation evolved, which was similar for the silicone and the polyurethane.
  •  
3.
  •  
4.
  • Hong, Jaan, et al. (författare)
  • A new in vitro model to study interaction between whole blood and biomaterials. Studies of platelet and coagulation activation and the effect of aspirin
  • 1999
  • Ingår i: Biomaterials. - : Elsevier. - 0142-9612 .- 1878-5905. ; 20:7, s. 603-611
  • Tidskriftsartikel (refereegranskat)abstract
    • We have developed a versatile in vitro chamber model with a double purpose: first, to be able to study mechanisms of bio- incompatibility, and, second, to test biomaterials at all levels of interactions, in whole blood. The use of biomaterials in the form of microscope slides as walls in the chamber makes it possible to analyse both the biomaterial surface with regard to protein and cell binding, as well as the molecular events taking place in the fluid. Incubation of blood in the chamber, for 60 min at 37°C resulted in the rapid binding of complement and coagulation proteins and of leukocytes and platelets to polyvinylchloride (PVC) slides. The cells formed a layer which more or less covered the underlying surface. Unlike complement activation, as reflected by soluble C3a and C5b-9, the thrombin—antithrombin formation was completely nullified in cell-depleted plasma. Despite the fact that throm- bin—antithrombin generation was also negligible in platelet-rich plasma, inhibition of platelet aggregation on the material surface with aspirin resulted in suppressed generation of thrombin—antithrombin complexes. Taken together, the coagulation activation in the chamber was dependent on the presence of blood cells which suggests that bound/aggregated platelets initiate a sequence of events involving leukocytes that results in coagulation activation. 
  •  
5.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 18

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy