SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Borga Magnus)) pers:(Moreno Rodrigo)
 

Sökning: (WFRF:(Borga Magnus)) pers:(Moreno Rodrigo) > (2015) > Anisotropy Estimati...

Anisotropy Estimation of Trabecular Bone in Gray-Scale : Comparison Between Cone Beam and Micro Computed Tomography Data

Moreno, Rodrigo, 1973- (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Borga, Magnus (författare)
Linköpings universitet,Medicinsk informatik,Filosofiska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV
Klintström, Eva (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Region Östergötland, Röntgenkliniken i Linköping
visa fler...
Brismar, Torkel (författare)
Department of Radiology, Karolinska University Hospital at Huddinge, Huddinge, Sweden
Smedby, Örjan, 1956- (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Medicinska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Röntgenkliniken i Linköping
visa färre...
 (creator_code:org_t)
2015-04-08
2015
Engelska.
Ingår i: Developments in Medical Image Processing and Computational Vision. - Cham : Springer. - 9783319134062 - 9783319134079 ; , s. 207-220
  • Bokkapitel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Measurement of anisotropy of trabecular bone has clinical relevance in osteoporosis. In this study, anisotropy measurements of 15 trabecular bone biopsies from the radius estimated by different fabric tensors on images acquired through cone beam computed tomography (CBCT) and micro computed tomography (micro-CT) were compared. The results show that the generalized mean intercept length (MIL) tensor performs better than the global gray-scale structure tensor, especially when the von Mises-Fisher kernel is applied.  Also, the generalized MIL tensor yields consistent results between the two scanners. These results suggest that this tensor is appropriate for estimating anisotropy in images acquired in vivo through CBCT.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Fabric tensors; CBCT; Micro-CT; Generalized MIL tensor; GST; Trabecular bone
Medical Technology
Medicinsk teknologi

Publikations- och innehållstyp

ref (ämneskategori)
kap (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy