SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Edstrom E)) srt2:(2020-2024)"

Sökning: (WFRF:(Edstrom E)) > (2020-2024)

  • Resultat 1-10 av 45
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • de Kater, EP, et al. (författare)
  • Beyond the pedicle screw-a patent review
  • 2022
  • Ingår i: European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. - 1432-0932.
  • Tidskriftsartikel (refereegranskat)
  •  
2.
  • Frisk, H, et al. (författare)
  • Feasibility and Accuracy of Thoracolumbar Pedicle Screw Placement Using an Augmented Reality Head Mounted Device
  • 2022
  • Ingår i: Sensors (Basel, Switzerland). - : MDPI AG. - 1424-8220. ; 22:2
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: To investigate the accuracy of augmented reality (AR) navigation using the Magic Leap head mounted device (HMD), pedicle screws were minimally invasively placed in four spine phantoms. Methods: AR navigation provided by a combination of a conventional navigation system integrated with the Magic Leap head mounted device (AR-HMD) was used. Forty-eight screws were planned and inserted into Th11-L4 of the phantoms using the AR-HMD and navigated instruments. Postprocedural CT scans were used to grade the technical (deviation from the plan) and clinical (Gertzbein grade) accuracy of the screws. The time for each screw placement was recorded. Results: The mean deviation between navigation plan and screw position was 1.9 ± 0.7 mm (1.9 [0.3–4.1] mm) at the entry point and 1.4 ± 0.8 mm (1.2 [0.1–3.9] mm) at the screw tip. The angular deviation was 3.0 ± 1.4° (2.7 [0.4–6.2]°) and the mean time for screw placement was 130 ± 55 s (108 [58–437] s). The clinical accuracy was 94% according to the Gertzbein grading scale. Conclusion: The combination of an AR-HMD with a conventional navigation system for accurate minimally invasive screw placement is feasible and can exploit the benefits of AR in the perspective of the surgeon with the reliability of a conventional navigation system.
  •  
3.
  •  
4.
  • Manti, M., et al. (författare)
  • Excess of ovarian nerve growth factor impairs embryonic development and causes reproductive and metabolic dysfunction in adult female mice
  • 2020
  • Ingår i: FASEB Journal. - : John Wiley & Sons. - 0892-6638 .- 1530-6860. ; 34:11, s. 14440-14457
  • Tidskriftsartikel (refereegranskat)abstract
    • Nerve growth factor (NGF) is critical for the development and maintenance of the peripheral sympathetic neurons. NGF is also involved in the ovarian sympathetic innervation and in the development and maintenance of folliculogenesis. Women with the endocrine disorder, polycystic ovary syndrome (PCOS), have an increased sympathetic nerve activity and increased ovarian NGF levels. The role of ovarian NGF excess in the PCOS pathophysiology and in the PCOS-related features is unclear. Here, using transgenic mice overexpressesing NGF in the ovarian theca cells (17NF mice), we assessed the female embryonic development, and the reproductive and metabolic profile in adult females. Ovarian NGF excess caused growth restriction in the female fetuses, and a delayed gonocyte and primary oocyte maturation. In adulthood, the 17NF mice displayed irregular estrous cycles and altered ovarian expression of steroidogenic and epigenetic markers. They also exhibited an increased sympathetic output with increased circulating dopamine, and metabolic dysfunction reflected by aberrant adipose tissue morphology and function, impaired glucose metabolism, decreased energy expenditure, and hepatic steatosis. These findings indicate that ovarian NGF excess leads to adverse fetal development and to reproductive and metabolic complications in adulthood, mirroring common features of PCOS. This work provides evidence that NGF excess may be implicated in the PCOS pathophysiology.
  •  
5.
  •  
6.
  • Porru, E, et al. (författare)
  • Ventriculoperitoneal Shunt Treatment Increases 7 Alpha Hy-Droxy-3-Oxo-4-Cholestenoic Acid and 24-Hydroxycholesterol Concentrations in Idiopathic Normal Pressure Hydrocephalus
  • 2022
  • Ingår i: Brain sciences. - : MDPI AG. - 2076-3425. ; 12:11
  • Tidskriftsartikel (refereegranskat)abstract
    • Idiopathic normal pressure hydrocephalus (iNPH) is the most common form of hydrocephalus in the adult population, and is often treated with cerebrospinal fluid (CSF) drainage using a ventriculoperitoneal (VP) shunt. Symptoms of iNPH include gait impairment, cognitive decline, and urinary incontinence. The pathophysiology behind the symptoms of iNPH is still unknown, and no reliable biomarkers have been established to date. The aim of this study was to investigate the possible use of the oxysterols as biomarkers in this disease. CSF levels of the oxysterols 24S- and 27-hydroxycholesterol, as well as the major metabolite of 27-hydroxycholesterol, 7 alpha hydroxy-3-oxo-4-cholestenoic acid (7HOCA), were measured in iNPH-patients before and after treatment with a VP-shunt. Corresponding measurements were also performed in healthy controls. VP-shunt treatment significantly increased the levels of 7HOCA and 24S-hydroxycholesterol in CSF (p = 0.014 and p = 0.037, respectively). The results are discussed in relation to the beneficial effects of VP-shunt treatment. Furthermore, the possibility that CSF drainage may reduce an inhibitory effect of transiently increased pressure on the metabolic capacity of neuronal cells in the brain is discussed. This capacity includes the elimination of cholesterol by the 24S-hydroxylase mechanisms.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  • Burstrom, G, et al. (författare)
  • Augmented reality navigation in spine surgery: a systematic review
  • 2021
  • Ingår i: Acta neurochirurgica. - : Springer Science and Business Media LLC. - 0942-0940 .- 0001-6268. ; 163:3, s. 843-852
  • Tidskriftsartikel (refereegranskat)abstract
    • BackgroundConventional spinal navigation solutions have been criticized for having a negative impact on time in the operating room and workflow. AR navigation could potentially alleviate some of these concerns while retaining the benefits of navigated spine surgery. The objective of this study is to summarize the current evidence for using augmented reality (AR) navigation in spine surgery.MethodsWe performed a systematic review to explore the current evidence for using AR navigation in spine surgery. PubMed and Web of Science were searched from database inception to November 27, 2020, for data on the AR navigation solutions; the reported efficacy of the systems; and their impact on workflow, radiation, and cost-benefit relationships.ResultsIn this systematic review, 28 studies were included in the final analysis. The main findings were superior workflow and non-inferior accuracy when comparing AR to free-hand (FH) or conventional surgical navigation techniques. A limited number of studies indicated decreased use of radiation. There were no studies reporting mortality, morbidity, or cost-benefit relationships.ConclusionsAR provides a meaningful addition to FH surgery and traditional navigation methods for spine surgery. However, the current evidence base is limited and prospective studies on clinical outcomes and cost-benefit relationships are needed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 45

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy