SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Friberg Johan)) lar1:(gu) srt2:(2000-2004)"

Sökning: (WFRF:(Friberg Johan)) lar1:(gu) > (2000-2004)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Friberg, Bertil, 1950, et al. (författare)
  • One-year prospective three-center study comparing the outcome of a "soft bone implant" (prototype Mk IV) and the standard Brånemark implant.
  • 2003
  • Ingår i: Clinical implant dentistry and related research. - 1523-0899. ; 5:2, s. 71-7
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Oral implant treatment ad modum Brånemark has been used for decades in the rehabilitation of edentate and partially dentate patients. Posterior jaw regions frequently exhibit bone of poor texture, and it is often difficult to obtain primary stability. Thus, it may prove beneficial to deviate from the original protocol and to use implants with a modified design, for example, with a slightly tapered geometry. PURPOSE: The purpose of the investigation was to compare the early behavior of a modified (prototype Mk IV, Brånemark System, Nobel Biocare AB, Gothenburg, Sweden; test) implant with that of the standard Brånemark implant (control) in regions of mainly type 4 bone. MATERIALS AND METHODS: Three Swedish centers participated, and a total of 44 patients were treated with oral implants for 39 maxillas and 5 mandibles. The study focused on the most distal right and left implant sites (88 implants), which were randomized to receive either a test or a control implant. Various parameters were recorded, such as registered insertion torque (OsseoCare), Nobel Biocare AB), wobbling during insertion, primary and secondary stability (as measured with resonance frequency), and marginal bone loss. The implants were followed up for 1 year. RESULTS: The test implant more frequently required a higher insertion torque and showed a significantly higher primary stability than the control implant. This difference in stability leveled out over time, and test and control implants exhibited similar secondary stability at abutment operation and at the 1-year visit. Wobbling during insertion was rarely recorded for either of the implant designs. The 1-year cumulative success rate was 93.1% for test implants and 88.4% for control implants. CONCLUSIONS: The modified implant design resulted in an increased primary stability, which may be important when placing implants in jaw regions of type 4 bone. However, independent of the achieved primary stability, successful implants tended to approach similar secondary stability in the two designs tested.
  •  
2.
  • Friberg, H., et al. (författare)
  • [Therapeutic hypothermia after cardiac arrest--a new link in the chain can save life]
  • 2004
  • Ingår i: Lakartidningen. - 0023-7205. ; 101:30-31, s. 2412-6
  • Tidskriftsartikel (refereegranskat)abstract
    • Sudden, unexpected cardiac arrest is a common cause of death. Among patients who are successfully resuscitated, a majority dies without regaining consciousness. Therapeutic hypothermia has recently been shown to improve neurological outcome in two randomized studies and to improve survival in one of them. Based on the two studies, international evidence-based recommendations have been proposed and published (ILCOR). In this review we discuss the theoretical background of hypothermic neuroprotection and therapeutic implications. We propose that victims of cardiac arrest with return of spontaneous circulation and persistent unconsciousness are considered for hypothermia treatment and that data from treated patients are collected in a common website database (see: www.scctg.org) to allow further evaluation of the use of ICU resources, efficacy of hypothermia treatment and potential risks.
  •  
3.
  • Sundelin, Karin, et al. (författare)
  • Posterior capsule opacification with AcrySof and poly(methyl methacrylate) intraocular lenses. Comparative study with a 3-year follow-up
  • 2001
  • Ingår i: Journal of cataract and refractive surgery. - 0886-3350. ; 27:10, s. 1586-1590
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether reports of reduced posterior capsule opacification (PCO) rates with AcrySof intraocular lenses (IOLs) are applicable to a mixed group of cataract patients in everyday surgical practice. SETTING: Department of Ophthalmology, Kärnsjukhuset, Skövde, Sweden. METHODS: A retrospective study comparing a study group receiving an AcrySof IOL (n = 145) and a group receiving a poly(methyl methacrylate) (PMMA) IOL (n = 153) was performed. The follow-up was 3 years in both groups. The performance of a neodymium:YAG laser capsulotomy was used as the end point for clinically significant PCO. RESULTS: Nine capsulotomies (6.2%) were performed in the AcrySof group and 34 (22.2%) in the PMMA group. The difference in the capsulotomy rate between the 2 groups was highly significant (P <.001). The relative risk was 3.6 times higher in the PMMA group. CONCLUSIONS: There was a significant difference in the frequency of capsulotomy between AcrySof and PMMA IOLs in a mixed group of cataract patients in everyday clinical practice. This finding indicates the importance of the IOL type in PCO formation.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy