SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Hedelin M.)) srt2:(2020-2023)"

Sökning: (WFRF:(Hedelin M.)) > (2020-2023)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Hedelin, Beatrice, 1974-, et al. (författare)
  • What's left before participatory modeling can fully support real-world environmental planning processes : A case study review
  • 2021
  • Ingår i: Environmental Modelling & Software. - : Elsevier BV. - 1364-8152 .- 1873-6726. ; 143
  • Tidskriftsartikel (refereegranskat)abstract
    • In environmental participatory modeling (PM), both computer and non-computer-based modeling techniques are used to aid participatory problem description, solution, and decision-making actions in environmental contexts. Although many PM case studies have been published, few efforts have sought to systematically describe and understand dominant PM processes or establish best practices for PM. As a first step, we have reviewed a random sample of environmental PM case study articles (n = 60) using a novel PM process evaluation instrument. We found that significant work likely remains for PM to fully support participatory and integrated planning processes. While PM reports systematically address knowledge integration and learning, they often neglect the facilitation of a multi-value perspective within a democratic process, and the integration across organizations within a governance system. If not reported, we suspect these aspects are also neglected in practice. We conclude with key research and practice issues for improving PM as an approach for real-world participatory planning and governance.
  •  
2.
  • Hedelin, Henrik, 1975, et al. (författare)
  • Postoperative stability following a triple pelvic osteotomy is affected by implant configuration: a finite element analysis
  • 2022
  • Ingår i: Journal of Orthopaedic Surgery and Research. - : Springer Science and Business Media LLC. - 1749-799X. ; 17:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background The triple pelvic osteotomy is an established surgical method with multiple modifications regarding surgical technique and choice of implant. The stability of the osteotomy is affected by numerous factors, and among these, the three-dimensional implant configuration is a scientifically less explored aspect. Methods We used a finite element model of a hemi-pelvis with a standardized triple osteotomy to calculate relative flexibility for loads in all translational degrees of freedom for five different implant configurations. Two of the configurations used entry points only feasible when implant removal was not necessary. Results The stability of the osteotomy improved with an increased distance between the implants in the plane of the osteotomy as well as for a more perpendicular angle relative to the osteotomy plane. The implant configurations with more entry points available made this easier to adhere to. Conclusion The use of bioabsorbable implants may provide better opportunities for optimal implant constructs which can, to a certain degree, compensate for the lesser mechanical stiffness of bioabsorbable polymers as compared to metal implants.
  •  
3.
  • Hedelin, Henrik, 1975, et al. (författare)
  • Stability in Pelvic Triple Osteotomies in Children Using Resorbable PLGA Screws for Fixation
  • 2021
  • Ingår i: Journal of Pediatric Orthopaedics. - : Ovid Technologies (Wolters Kluwer Health). - 0271-6798. ; 41:9
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: The triple pelvic osteotomy (TPO) is a major redirectional osteotomy used to improve the acetabular coverage of the femoral head in selected pediatric patients with hip disorders. Traditionally the iliac osteotomy is stabilized by metal screws that require a second surgery for removal. Despite favorable results for both adults and children in related pelvic osteotomies, resorbable implants have not previously been used for TPOs. This study aims to suggest a novel modified TPO surgical method in children using resorbable poly lactic-co-glycolic acid (PLGA) screws for fixation and to radiographically evaluate the postoperative stability achieved by these implants in a case series. Methods: All patients (n=11) with dysplasia of the hip (2), Perthe disease (5), or Down syndrome (4), who underwent primary TPO surgery during 2013 to 2019, using resorbable PLGA screws for fixation were included. The stability of the osteotomy was evaluated in the postoperative radiograph series using the acetabular index, migration percentage, Sharp's angle and the center-edge angle. The osteotomy angle was introduced as a parameter to confirm the postoperative integrity of the achieved correction. All cases were evaluated until radiographic healing of the iliac osteotomy. Hospital notes were analyzed for complications or local reactions in relation to the implants. Results: In all studied hips, the overall achieved correction was well maintained. The mean (SD) correction achieved, from the preoperative images to the last measurable postoperative image, was a 16.7 degrees decrease for Sharp angle, a 20.9 degrees decrease in acetabular index and a 24.7 degrees increase for the center-edge angle, respectively. There were no complications related to the bioabsorption of the implants. Conclusion: The present findings suggest that the modified TPO method, using resorbable PLGA screws, provides sufficient stability and appears to be a promising alternative to traditional TPO. Avoiding implant removal is a major benefit in a pediatric population. Resorbable screws enable the surgeon to place implants with more degrees of freedom since later implant removal is not a limiting factor.
  •  
4.
  • Identeg, Fredrik, 1990, et al. (författare)
  • Low occurrence of MRI spinal changes in elite climbing athletes; a cross-sectional study.
  • 2023
  • Ingår i: BMC sports science, medicine & rehabilitation. - : Springer Science and Business Media LLC. - 2052-1847. ; 15:1
  • Tidskriftsartikel (refereegranskat)abstract
    • To examine the occurrence of magnetic resonance imaging (MRI) changes in the thoracolumbar spine among elite climbing athletes.All climbers of the Swedish national sport climbing team (n=8), and individuals having trained for selection to the national team (n=11), were prospectively included. A control group, matched in age and sex, were recruited. All participants underwent a thoracolumbar MRI (1.5T, T1- and T2-weighted imaging), evaluated according to Pfirrmann classification, modified Endplate defect score, Modic changes, apophyseal injuries and spondylolisthesis. Pfirrmann≥3, Endplate defect score≥2 and Modic≥1 was defined as degenerative findings.Fifteen individuals, 8 women, participated in both the climbing group (mean age 23.1, SD 3.2years) and the control group respectively (mean age 24.3, SD 1.5years). In the climbing group, 6.1% of the thoracic and 10.6% of the lumbar intervertebral discs showed signs of degeneration according to Pfirrmann. One disc with a grade above 3 was present. Modic changes in the thoracic/lumbar spine were prevalent in 1.7%/1.3% of the vertebrae. Degenerative endplate changes according to the Endplate defect score were found in 8.9% and 6.6% of the thoracic and lumbar spinal segments of the climbing group, respectively. Two apophyseal injuries were found, while no participants displayed signs of spondylolisthesis. There was no difference in point-prevalence of radiographic spinal changes between climbers and controls (0.07
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy