1. |
- Brändén, Gisela, 1975, et al.
(författare)
-
Coherent diffractive imaging of microtubules using an X-ray laser.
- 2019
-
Ingår i: Nature communications. - : Springer Science and Business Media LLC. - 2041-1723. ; 10:1
-
Tidskriftsartikel (refereegranskat)abstract
- X-ray free electron lasers (XFELs) create new possibilities for structural studies of biological objects that extend beyond what is possible with synchrotron radiation. Serial femtosecond crystallography has allowed high-resolution structures to be determined from micro-meter sized crystals, whereas single particle coherent X-ray imaging requires development to extend the resolution beyond a few tens of nanometers. Here we describe an intermediate approach: the XFEL imaging of biological assemblies with helical symmetry. We collected X-ray scattering images from samples of microtubules injected across an XFEL beam using a liquid microjet, sorted these images into class averages, merged these data into a diffraction pattern extending to 2nm resolution, and reconstructed these data into a projection image of the microtubule. Details such as the 4nm tubulin monomer became visible in this reconstruction. These results illustrate the potential of single-molecule X-ray imaging of biological assembles with helical symmetry at room temperature.
|
|
2. |
- Kalland, Kristine, et al.
(författare)
-
Similar outcome of femoral neck fractures treated with Pinloc or Hansson Pins: 1-year data from a multicenter randomized clinical study on 439 patients
- 2019
-
Ingår i: Acta Orthopaedica. - : Medical Journals Sweden AB. - 1745-3674 .- 1745-3682. ; 90:6, s. 542-546
-
Tidskriftsartikel (refereegranskat)abstract
- Background and purpose - There are few reports on the efficiency of the Hansson Pinloc System (Pinloc) for fixation of femoral neck fractures. We compare Pinloc with the commonly used Hansson Pin System in a randomized clinical trial. The primary outcome measure is non-union or avascular necrosis within 2 years. We now report fracture failures and reoperations within the first year. Patients and methods - Between May 2014 and February 2017, 439 patients were included in the study. They were above 50 years of age and treated for a femoral neck fracture at 9 orthopedic departments in Sweden. They were randomized to either Pinloc or Hansson pins. The fractures were grouped as (a) non-displaced regardless of age, (b) displaced in patients < 70 years, or (c) >= 70 years old, but deemed unfit to undergo arthroplasty. Follow-up with radiographs and outpatient visits were at 3 and 12 months. Failure was defined as early displacement/non-union, symptomatic segmental collapse, or deep infection. Results - 1-year mortality was 11%. Of the 325 undisplaced fractures, 12% (21/169) Pinloc and 13% (20/156) Hansson pin patients had a failure during the first year. The reoperation frequencies were 10% (16/169) and 8% (13/156) respectively. For the 75 patients 50-69 years old with displaced fractures, 11/39 failures occurred in the Pinloc group and 11/36 in the Hansson group, and 8/39 versus 9/36 patients were reoperated. Among those 39 patients >= 70 years old, 7/21 failures occurred in the Pinloc group and 4/18 in the Hansson group. Reoperation frequencies were 4/21 for Pinloc and 3/18 for the Hansson pin patients. No statistically significant differences were found in any of the outcomes between the Pinloc and Hansson groups. Interpretation - We found no advantages with Pinloc regarding failure or reoperation frequencies in this 1-year follow-up.
|
|