SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Meloni C)) srt2:(2020-2024) srt2:(2021)"

Sökning: (WFRF:(Meloni C)) srt2:(2020-2024) > (2021)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Niemi, MEK, et al. (författare)
  • 2021
  • swepub:Mat__t
  •  
2.
  •  
3.
  • Abramowicz, H., et al. (författare)
  • Conceptual design report for the LUXE experiment
  • 2021
  • Ingår i: European Physical Journal-Special Topics. - : Springer Science and Business Media LLC. - 1951-6355 .- 1951-6401. ; 230:11, s. 2445-2560
  • Tidskriftsartikel (refereegranskat)abstract
    • This Conceptual Design Report describes LUXE (Laser Und XFEL Experiment), an experimental campaign that aims to combine the high-quality and high-energy electron beam of the European XFEL with a powerful laser to explore the uncharted terrain of quantum electrodynamics characterised by both high energy and high intensity. We will reach this hitherto inaccessible regime of quantum physics by analysing high-energy electron-photon and photon-photon interactions in the extreme environment provided by an intense laser focus. The physics background and its relevance are presented in the science case which in turn leads to, and justifies, the ensuing plan for all aspects of the experiment: Our choice of experimental parameters allows (i) field strengths to be probed where the coupling to charges becomes non-perturbative and (ii) a precision to be achieved that permits a detailed comparison of the measured data with calculations. In addition, the high photon flux predicted will enable a sensitive search for new physics beyond the Standard Model. The initial phase of the experiment will employ an existing 40 TW laser, whereas the second phase will utilise an upgraded laser power of 350 TW. All expectations regarding the performance of the experimental set-up as well as the expected physics results are based on detailed numerical simulations throughout.
  •  
4.
  • Esposito, Marco, 1965, et al. (författare)
  • MACHINED VERSUS CAST ABUTMENTS FOR DENTAL IMPLANTS: A 1-YEAR WITHIN-PATIENT MULTICENTRE RANDOMIZED CONTROLLED TRIAL ASSESSING MARGINAL SEAL CAPACITY AND OUTCOMES
  • 2021
  • Ingår i: Clinical Trials in Dentistry. - 2784-9015. ; 3:2, s. 19-31
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE To compare clinical outcomes of machined titanium abutments (machined group) versus cast cobalt-chrome abutments (cast group) and to evaluate in vitro their implant fit. MATERIALS AND METHODS This study comprised two parts. In the in vitro part, the im-plant–abutment fit of 5 cast abutments and 5 machined abutments screwed on with a torque of 30 Ncm was qualitatively and quantitatively evaluated using micro-computed tomography (µ-CT) and AgNO3 to reveal connection gaps. In the clinical part, 31 partially edentulous subjects received two single non-adjacent implant-supported crowns at three centres. At impression taking, three and a half months after implant placement, implants were randomized to receive a machined or cast abutment according to a wi-thin-patient study design. Unfortunately, four patients dropped out and one patient lost one implant before randomization, so only 26 patients had their implants randomized. Outcome measures were: prosthesis and implant failures, any complications, and radiographic peri-implant marginal bone level changes. Patients were followed up to 1 year after loading. RESULTS The fit of the implant–abutment connection was assessed in vitro using µ-CT scans. No gaps were revealed at any of the machined or cast abutments tested. In the clinical part, after randomization, three patients dropped out, no implant failed, but one crown on a cast abutment was replaced. The between-group difference in prosthesis failure was not statistically different (McNemar chi-square test P = 1.0; difference in proportions = 0.039). One complication occurred in each group, the difference not being statistically different (McNemar test P = 1.000; difference in proportions = 0; 95% CI 0.06 to 15.99). Both groups presented statistically significant peri-implant marginal bone loss from implant placement to 1 year after loading, respectively-0.76 ± 1.01 mm for machined and-0.69 ± 0.82 mm for cast abutments, with no statistically significant differences between the two groups (mean difference 0.07 mm; 95% CI-0.54 to 0.67; P = 0.828). Both groups gradually lost marginal peri-implant bone from loading to 1 year after loading but this was not significantly different, respectively-0.06 ± 0.56 mm for machined and-0.10 ± 0.29 mm for cast abutments, with no statistically significant differences between the two groups (P = 0.739; mean difference 0.07 mm; 95% CI-0.12 to 0.16; P = 0.739). CONCLUSIONS Our clinical data suggests that implant prognosis up to 1 year after loading is not affected by using machined or cast abutments. In support of these findings, in vitro analysis proved that both types of abutments allow a tight fit with no gaps. The-refore, for the time being dentists should feel free to choose whichever type they prefer. However, these preliminary results need to be confirmed by larger trials with at least 10 years of follow-up.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy