SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Nunez G.)) srt2:(2010-2014) srt2:(2010)"

Sökning: (WFRF:(Nunez G.)) srt2:(2010-2014) > (2010)

  • Resultat 1-3 av 3
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Dubernet, M. L., et al. (författare)
  • Virtual atomic and molecular data centre
  • 2010
  • Ingår i: Journal of Quantitative Spectroscopy and Radiative Transfer. - 0022-4073 .- 1879-1352. ; 111:15, s. 2151-2159
  • Tidskriftsartikel (refereegranskat)abstract
    • The Virtual Atomic and Molecular Data Centre (VAMDC, http://www.vamdc.eu) is a European Union funded collaboration between groups involved in the generation, evaluation, and use of atomic and molecular data. VAMDC aims to build a secure, documented, flexible and interoperable e-science environment-based interface to existing atomic and molecular data. The project will cover establishing the core consortium, the development and deployment of the infrastructure and the development of interfaces to the existing atomic and molecular databases. It will also provide a forum for training potential users and dissemination of expertise worldwide. This review describes the scope of the VAMDC project; it provides a survey of the atomic and molecular data sets that will be included plus a discussion of how they will be integrated. Some applications of these data are also discussed.
  •  
2.
  •  
3.
  • Schlegel, Todd T., et al. (författare)
  • Accuracy of advanced versus strictly conventional 12-lead ECG for detection and screening of coronary artery disease, left ventricular hypertrophy and left ventricular systolic dysfunction
  • 2010
  • Ingår i: BMC Cardiovascular Disorders. - : Springer Science and Business Media LLC. - 1471-2261. ; 10
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Resting conventional 12-lead ECG has low sensitivity for detection of coronary artery disease (CAD) and left ventricular hypertrophy (LVH) and low positive predictive value (PPV) for prediction of left ventricular systolic dysfunction (LVSD). We hypothesized that a similar to 5-min resting 12-lead advanced ECG test ("A-ECG") that combined results from both the advanced and conventional ECG could more accurately screen for these conditions than strictly conventional ECG. Methods: Results from nearly every conventional and advanced resting ECG parameter known from the literature to have diagnostic or predictive value were first retrospectively evaluated in 418 healthy controls and 290 patients with imaging-proven CAD, LVH and/or LVSD. Each ECG parameter was examined for potential inclusion within multi-parameter A-ECG scores derived from multivariate regression models that were designed to optimally screen for disease in general or LVSD in particular. The performance of the best retrospectively-validated A-ECG scores was then compared against that of optimized pooled criteria from the strictly conventional ECG in a test set of 315 additional individuals. Results: Compared to optimized pooled criteria from the strictly conventional ECG, a 7-parameter A-ECG score validated in the training set increased the sensitivity of resting ECG for identifying disease in the test set from 78% (72-84%) to 92% (88-96%) (P < 0.0001) while also increasing specificity from 85% (77-91%) to 94% (88-98%) (P < 0.05). In diseased patients, another 5-parameter A-ECG score increased the PPV of ECG for LVSD from 53% (41-65%) to 92% (78-98%) (P < 0.0001) without compromising related negative predictive value. Conclusion: Resting 12-lead A-ECG scoring is more accurate than strictly conventional ECG in screening for CAD, LVH and LVSD.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-3 av 3

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy