SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Qi Lu)) lar1:(mdh)
 

Sökning: (WFRF:(Qi Lu)) lar1:(mdh) > (2019) > Performance analysi...

Performance analysis of two-stage compression transcritical CO2 refrigeration system with R290 mechanical subcooling unit

Liu, S. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China
Lu, F. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China
Dai, B. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China
visa fler...
Nian, V. (författare)
Energy Studies Institute, National University of Singapore, Singapore
Li, Hailong, 1976- (författare)
Mälardalens högskola,Framtidens energi
Qi, H. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China
Li, J. (författare)
Tianjin Key Laboratory of Refrigeration Technology, Tianjin University of Commerce, China
visa färre...
 (creator_code:org_t)
Elsevier Ltd, 2019
2019
Engelska.
Ingår i: Energy. - : Elsevier Ltd. - 0360-5442 .- 1873-6785. ; 189
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The use of carbon dioxide (CO2) as refrigerant is driven by the need to phase down the traditional synthetic refrigerant so as to mitigate the warming climate. In this study, the thermal performance of a two-stage compression transcritical CO2 refrigeration system with R290 mechanical subcooling unit is conducted. The goal is to obtain the maximum coefficient of performance (COP) of five different mechanical subcooling systems under the optimal subcooling temperature and compressor discharge pressure. The two-throttling and two-stage compression high-pressure mechanical subcooling system is found to have a higher COP. When the evaporation temperature is −30 °C, the COP of the two-throttling and two-stage compression high-pressure mechanical subcooling system is improved by 76.74%. The COP of the two-throttling and two-stage compression high-pressure mechanical subcooling system is 1.52 at an ambient temperature of 40 °C, which is 21.87% higher than that of the two-throttling and two-stage compression low-pressure mechanical subcooling system. The power consumption ratio of one-throttling and two-stage compression low-pressure mechanical subcooling system is significantly higher than that of other systems. From a comprehensive analysis of the proposed four systems, the two-throttling and two-stage compression high-pressure mechanical subcooling system has the best performance over all other systems. 

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering (hsv//eng)

Nyckelord

CO2 refrigeration
Mechanical subcooling
R290
Transcritical system
Two-stage compression
Two-throttling

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Energy (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Liu, S.
Lu, F.
Dai, B.
Nian, V.
Li, Hailong, 197 ...
Qi, H.
visa fler...
Li, J.
visa färre...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
Artiklar i publikationen
Energy
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy