SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Saunders E)) srt2:(2005-2009)"

Sökning: (WFRF:(Saunders E)) > (2005-2009)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Horsley, A R, et al. (författare)
  • Lung clearance index is a sensitive, repeatable and practical measure of airways disease in adults with cystic fibrosis.
  • 2008
  • Ingår i: Thorax. - : BMJ. - 1468-3296 .- 0040-6376. ; 63:2, s. 135-40
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Lung clearance index (LCI) is a sensitive marker of early lung disease in children but has not been assessed in adults. Measurement is hindered by the complexity of the equipment required. The aims of this study were to assess performance of a novel gas analyser (Innocor) and to use it as a clinical tool for the measurement of LCI in cystic fibrosis (CF). METHODS: LCI was measured in 48 healthy adults, 12 healthy school-age children and 33 adults with CF by performing an inert gas washout from 0.2% sulfur hexafluoride (SF6). SF6 signal:noise ratio and 10-90% rise time of Innocor were compared with a mass spectrometer used in similar studies in children. RESULTS: Compared with the mass spectrometer, Innocor had a superior signal:noise ratio but a slower rise time (150 ms vs 60 ms) which may limit its use in very young children. Mean (SD) LCI in healthy adults was significantly different from that in patients with CF: 6.7 (0.4) vs 13.1 (3.8), p<0.001. Ten of the patients with CF had forced expiratory volume in 1 s > or = 80% predicted but only one had a normal LCI. LCI repeats were reproducible in all three groups of subjects (mean intra-visit coefficient of variation ranged from 3.6% to 5.4%). CONCLUSIONS: Innocor can be adapted to measure LCI and affords a simpler alternative to a mass spectrometer. LCI is raised in adults with CF with normal spirometry, and may prove to be a more sensitive marker of the effects of treatment in this group.
  •  
3.
  • Saunders, Daniel G, et al. (författare)
  • TANF workers' responses to battered women and the impact of brief worker training : What survivors report
  • 2005
  • Ingår i: Violence against Women. - : SAGE Publications. - 1077-8012 .- 1552-8448. ; 11:2, s. 227-254
  • Tidskriftsartikel (refereegranskat)abstract
    • Battered women (n = 159) report on their experiences with their Temporary Assistance to Needy Families (TANF) caseworkers. Workers most often ask about physical harm, feelings of fear, and police involvement. They least often create a safety plan, give information about work exemptions, and ask whether the partner had a gun. Women's major reasons for not talking about abuse are that the worker did not ask and a fear of negative outcomes. Workers who attended a 1-day training are more likely than untrained workers to discuss the women's fear and physical harm, to help develop a safety plan, and to be viewed as generally helpful.
  •  
4.
  • Timberg, Pontus, et al. (författare)
  • Potential for lower absorbed dose in digital mammography: A JAFROC experiment using clinical hybrid images with simulated dose reduction
  • 2006
  • Ingår i: Progress in Biomedical Optics and Imaging - Proceedings of SPIE. - : SPIE. - 1605-7422. ; 6146, s. 14614-14614
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • To determine how image quality linked to tumor detection is affected by reducing the absorbed dose to 50% and 30% of the clinical levels represented by an average glandular dose (AGO) level of 1.3 mGy for a standard breast according to European guidelines. Materials and methods: 90 normal, unprocessed images were acquired from the screening department using a full-field digital mammography (FFDM) unit Mammomat Novation (Siemens). Into 40 of these, one to three simulated tumors were inserted per image at various positions. These tumors represented irregular-shaped malignant masses. Dose reduction was simulated in all 90 images by adding simulated quantum noise to represent images acquired at 50% and 30% of the original dose, resulting in 270 images, which were subsequently processed for final display. Four radiologists participated in a free-response receiver operating characteristics (FROG) study in which they searched for and marked suspicious positions of the masses as well as rated their degree of suspicion of occurrence on a one to four scale. Using the jackknife FROG (JAFROC) method, a score between 0 and 1 (where 1 represents best performance), referred to as a figure-of-merit (FOM), was calculated for each dose level. Results: The FOM was 0.73, 0.70, and 0.68 for the 100%, 50% and 30% dose levels, respectively. Using Analysis of the Variance (ANOVA) to test for statistically significant differences between any two of the three FOMs revealed that they were not statistically distinguishable (p-value of 0.26). Conclusion: For the masses used in this experiment, there was no significant change in detection by increasing quantum noise, thus indicating a potential for dose reduction.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy