SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Schneider Harald))
 

Sökning: (WFRF:(Schneider Harald)) > (1999) > Positron emission t...

Positron emission tomography and radioimmunotargeting : aspects ofquantification and dosimetry

Lubberink, Mark (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,BMS
Lundqvist, Hans (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,BMS
Westlin, Jan-Erik (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,Oncology
visa fler...
Tolmachev, Vladimir (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,BMS
Schneider, Harald (författare)
Lövqvist, Anna (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,BMS
Sundin, Anders (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,RAD
Carlsson, Jörgen (författare)
Uppsala universitet,Institutionen för onkologi, radiologi och klinisk immunologi,BMS
visa färre...
 (creator_code:org_t)
1999
1999
Engelska.
Ingår i: Acta Oncologica. - 0284-186X .- 1651-226X. ; 38:3, s. 343-349
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Positron emission tomography (PET) is a medical imaging tool with high resolution and good quantitative properties, which makes it suitable for in vivo quantification of radioimmunotargeting agents. Most radionuclides used in radioimmunotherapy have positron-emitting analogues, which can be used for PET imaging, and this opens the possibility of performing dosimetry with PET. These isotopes, however, often emit gamma radiation and high-energy positrons in their decay, influencing the imaging properties of PET. Spatial resolution, reconstructed background and line source recovery for a number of non-pure positron emitters were investigated and compared with the imaging properties of 18F. PET imaging properties did not degrade severely for these non-pure positron emitters, but caution has to be applied when doing quantitative measurements. To assess the possibility of conducting PET studies during therapy, by combining, for example, a small amount of 124I with 131I, the influence of the presence of large amounts of gamma radiation on PET count rate characteristics was studied. The results of these studies were related to the necessary amounts of radioactivity needed for treatment of post-operative remains of glioma. The results indicate that the count rate capabilities of 2D PET permit PET studies for dose evaluation during radioimmunotherapy.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy