SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(WFRF:(Stewart E)) lar1:(miun) srt2:(2012)"

Sökning: (WFRF:(Stewart E)) lar1:(miun) > (2012)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Fröjdh, Erik, et al. (författare)
  • Depth of interaction and bias voltage dependence of the spectral response in a pixellated CdTe detector operating in time-over-threshold mode subjected to monochromatic X-rays
  • 2012
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 7:3, s. Art. no. C03002-
  • Tidskriftsartikel (refereegranskat)abstract
    • High stopping power is one of the most important figures of merit for X-ray detectors. CdTe is a promising material but suffers from: material defects, non-ideal charge transport and long range X-ray fluorescence. Those factors reduce the image quality and deteriorate spectral information. In this project we used a monochromatic pencil beam collimated through a 20ÎŒm pinhole to measure the detector spectral response in dependance on the depth of interaction. The sensor was a 1mm thick CdTe detector with a pixel pitch of 110ÎŒm, bump bonded to a Timepix readout chip operating in Time-Over-Threshold mode. The measurements were carried out at the Extreme Conditions beamline I15 of the Diamond Light Source. The beam was entering the sensor at an angle of ∌20 degrees to the surface and then passed through ∌25 pixels before leaving through the bottom of the sensor. The photon energy was tuned to 77keV giving a variation in the beam intensity of about three orders of magnitude along the beam path. Spectra in Time-over-Threshold (ToT) mode were recorded showing each individual interaction. The bias voltage was varied between -30V and -300V to investigate how the electric field affected the spectral information. For this setup it is worth noticing the large impact of fluorescence. At -300V the photo peak and escape peak are of similar height. For high bias voltages the spectra remains clear throughout the whole depth but for lower voltages as -50V, only the bottom part of the sensor carries spectral information. This is an effect of the low hole mobility and the longer range the electrons have to travel in a low field. © 2012 IOP Publishing Ltd and Sissa Medialab srl.
  •  
2.
  • Maneuski, D., et al. (författare)
  • Imaging and spectroscopic performance studies of pixellated CdTe Timepix detector
  • 2012
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 7:1, s. Art. no. C01038-
  • Tidskriftsartikel (refereegranskat)abstract
    • In this work the results on imaging and spectroscopic performances of 14 × 14 × 1 mm CdTe detectors with 55 × 55ÎŒm and 110 × 110ÎŒm pixel pitch bump-bonded to a Timepix chip are presented. The performance of the 110 × 110ÎŒm pixel detector was evaluated at the extreme conditions beam line I15 of the Diamond Light Source. The energy of X-rays was set between 25 and 77 keV. The beam was collimated through the edge slits to 20ÎŒm FWHM incident in the middle of the pixel. The detector was operated in the time-over-threshold mode, allowing direct energy measurement. Energy in the neighbouring pixels was summed for spectra reconstruction. Energy resolution at 77 keV was found to be ΔE/E = 3.9%. Comparative imaging and energy resolution studies were carried out between two pixel size detectors with a fluorescence target X-ray tube and radioactive sources. The 110 × 110ÎŒm pixel detector exhibited systematically better energy resolution in comparison to 55 × 55ÎŒm. An imaging performance of 55 × 55ÎŒm pixellated CdTe detector was assessed using the Modulation Transfer Function (MTF) technique and compared to the larger pixel. A considerable degradation in MTF was observed for bias voltages below -300 V. Significant room for improvement of the detector performance was identified both for imaging and spectroscopy and is discussed. © 2012 IOP Publishing Ltd and SISSA.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
O'Shea, V. (2)
Stewart, G. (2)
Fröjdh, Christer (2)
Fröjdh, Erik (2)
Maneuski, D. (2)
Gimenez, E (2)
visa fler...
Marchal, J (2)
Wilhelm, H (2)
Wraight, K. (1)
Zain, R (1)
Thungström, Göran (1)
Norlin, Börje (1)
Tartoni, N. (1)
Modh Zain, R (1)
Astromskas, V (1)
visa färre...
Lärosäte
Mittuniversitetet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Teknik (2)
År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy