SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "(hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kardiologi)) pers:(James Stefan 1964) hsvcat:3 srt2:(2010-2014)"

Sökning: (hsv:(MEDICIN OCH HÄLSOVETENSKAP) hsv:(Klinisk medicin) hsv:(Kardiologi)) pers:(James Stefan 1964) hsvcat:3 > (2010-2014)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Koutouzis, Michael, et al. (författare)
  • Unfractionated heparin administration in patients treated with bivalirudin during primary percutaneous coronary intervention is associated lower mortality and target lesion thrombosis : a report from the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
  • 2011
  • Ingår i: Heart. - : BMJ. - 1355-6037 .- 1468-201X. ; 97:18, s. 1484-1488
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Bivalirudin reduces bleeding events and is associated with a lower mortality than the combination of unfractionated heparin (UFH) and glycoprotein IIb/IIIa inhibitor during primary percutaneous coronary intervention (PCI). However, the effect of adding UFH in patients with ST elevation myocardial infarction (STEMI) treated with bivalirudin during primary PCI is unknown.Methods: Patients enrolled in the national Swedish Coronary Angiography and Angioplasty Registry who underwent primary PCI due to STEMI with bivalirudin as anticoagulant were evaluated. Patients were divided into two groups: those treated with bivalirudin only and those treated with bivalirudin plus a bolus dose of UFH.Results: 2996 patients were included in the study: 1928 (64%) received only bivalirudin and 1068 (36%) received bivalirudin plus a bolus dose of UFH. The primary combined endpoint of death or target lesion thrombosis at 30 days occurred more often in the bivalirudin group (11.3% vs 6.5%, OR 0.55, 95% CI 0.41 to 0.72, p<0.001). This difference remained significant after adjustment (HR 0.64, 95% CI 0.44 to 0.95, p=0.03). Death at 30 days and definite target lesion thrombosis at 30 days did not differ between the two groups after adjustment (9.2% vs 5.1%, adjusted HR 0.66, 95% CI 0.42 to 1.03, p=0.07 and 2.3% vs 1.5%, adjusted HR 0.59, 95% CI 0.27 to 1.33, p=0.21, respectively).Conclusion: An additional bolus dose of UFH is associated with a lower rate of death or definite target lesion thrombosis at 30 days in patients undergoing primary PCI with bivalirudin as anticoagulant.
  •  
2.
  • Morice, Marie-Claude, et al. (författare)
  • Angiographic outcomes following stenting or coronary artery bypass surgery of the left main coronary artery : fifteen-month outcomes from the synergy between PCI with TAXUS express and cardiac surgery left main angiographic substudy (SYNTAX-LE MANS)
  • 2011
  • Ingår i: EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. - 1969-6213. ; 7:6, s. 670-679
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: The SYNTAX-LE MANS substudy prospectively evaluated 15-month angiographic and clinical outcomes in patients with treated left main (LM) disease. METHODS AND RESULTS: In the SYNTAX trial, 1,800 patients with three-vessel and/or LM disease were randomised to either CABG or PCI; of these, 271 LM patients were prospectively assigned to receive a 15-month angiogram. The primary endpoint for the CABG arm was the ratio of ≥50% to <100% obstructed/occluded grafts bypassing LM lesions to the number placed. The primary endpoint for the PCI arm was the proportion of patients with ≤50% diameter stenosis ('patent' stents) of treated LM lesions. Per protocol, no formal comparison between CABG and PCI arms was intended based on the differing primary endpoints. Available 15-month angiograms were analysed for 114 CABG and 149 PCI patients. At 15 months, 9.9% (26/263) of CABG grafts were 100% occluded and an additional 5.7% (15/263) were ≥50% to <100% occluded. Overall, 27.2% (31/114) of patients had ≥1 obstructed/occluded graft. The 15-month CABG MACCE rate was 8.8% (10/114) and MACCE at 15 months was not significantly associated with graft obstruction/occlusion (p=0.85). In the PCI arm, 92.4% (134/145) of patients had ≤50% diameter LM stenosis at 15 months (89.7% [87/97] distal LM lesions and 97.9% [47/48] non-distal LM lesions). The 15-month PCI MACCE rate was 12.8% (20/156) and this was significantly associated with lack of stent patency at 15 months (p<0.001), mainly due to repeat revascularisation. CONCLUSIONS: At 15 months, 15.6% (41/263) of grafts were at least 50% obstructed but this was not significantly associated with MACCE; 92.4% (134/145) of patients had stents that remained patent at 15 months, and stent restenosis was significantly associated with MACCE, predominantly due to revascularisation.
  •  
3.
  • Sarno, Giovanna, et al. (författare)
  • Lower risk of stent thrombosis and restenosis with unrestricted use of onew-generation drug-eluting stents: a report from the nationwide Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
  • 2012
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP): Policy B. - 0195-668X .- 1522-9645. ; 33:5, s. 606-613
  • Tidskriftsartikel (refereegranskat)abstract
    • To compare the long-term outcome after percutaneous coronary intervention with onew-generation drug-eluting stents (n-DES) to oolder generation DES (o-DES), and bare-metal stents (BMS) in a real-world population. less thanbrgreater than less thanbrgreater thanWe evaluated 94 384 consecutive stent implantations (BMS, n 64 631; o-DES, n 19 202; n-DES, n 10 551) in Sweden from November 2006 to October 2010. All cases of definite stent thrombosis (ST) and restenosis were documented in the Swedish Coronary Angiography and Angioplasty Registry (SCAAR). Older generation DES were classified as: Cypher and Cypher Select (Cordis Corporation, Miami, FL, USA), Taxus Express and Taxus Libert (Boston Scientific Corporation), and Endeavor (Medtronic Inc.) and n-DES as: Endeavor Resolute (Medtronic Inc.), XienceV, Xience Prime (Abbott Laboratories) and Promus, Promus Element (Boston Scientific Corporation). The Cox regression analyses unadjusted and adjusted for clinical and angiographic covariates showed a statistically significant lower risk of restenosis in n-DES compared with BMS [adjusted hazard ratio (HR) 0.29; 95 confidence interval (CI): 0.250.33] and o-DES (HR 0.62; 95 CI: 0.530.72). A lower risk of definite ST was found in n-DES compared with BMS (HR 0.38; 95 CI: 0.280.52) and o-DES (HR, 0.57; 95 CI: 0.410.79). The risk of death was significantly lower in n-DES compared with o-DES (adjusted HR: 0.77; 95 CI: 0.630.95) and BMS (adjusted HR: 0.55; 95 CI: 0.460.67). less thanbrgreater than less thanbrgreater thanPercutaneous coronary intervention with n-DES is associated with a 38 lower risk of clinically meaningful restenosis, a 43 lower risk of definite ST, and a 23 lower risk of death compared with o-DES in this observational study from a large real-world population.
  •  
4.
  • Stenestrand, Ulf, et al. (författare)
  • Safety and efficacy of drug-eluting vs. bare metal stents in patients with diabetes mellitus : long-term follow-up in the Swedish Coronary Angiography and Angioplasty Registry (SCAAR)
  • 2010
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 31:2, s. 177-186
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Patients with diabetes mellitus have more extensive coronary artery disease, more disease progression, and restenosis. The use of drug-eluting stents (DES) in these patients is widespread, despite uncertain long-term safety and efficacy. METHODS AND RESULTS: All consecutive patients with diabetes mellitus in Sweden who underwent percutaneous coronary intervention were entered into the Swedish Coronary Angiography and Angioplasty Registry (SCAAR) during 2003-06 with complete follow-up for 1-4 years (median 2.5). Patients who received at least one DES (n = 4754) were compared with those who received only bare metal stents (BMS) (n = 4956) at the index procedure. Combined outcome of death or myocardial infarction (MI) showed no difference for DES vs. BMS, relative risk (RR), 0.91 [95% confidence interval (CI), 0.77-1.06]. Myocardial infarction was significantly less common with DES in patients who received only one stent RR, 0.80 (95% CI, 0.66-0.96). The restenosis rate was 50% lower in DES-treated patients RR, 0.50 (95% CI, 0.35-0.70) and was associated with a higher adjusted RR of MI, RR, 5.03 (95% CI, 4.25-5.97). DES was associated with reduced restenosis rates in all subgroups of diabetic patients with the greatest benefit in stent diameters <3 mm or stent length >20 mm. The number of lesions treated with DES to prevent one restenosis ranged from 11 to 47 in various subgroups. CONCLUSION: This real-life registry study shows that restenosis was halved by DES in diabetic patients with stable or unstable coronary disease, with similar risk of death or MI up to 4 years compared with BMS.
  •  
5.
  • Storey, Robert F, et al. (författare)
  • Characterization of dyspnoea in PLATO study patients treated with ticagrelor or clopidogrel and its association with clinical outcomes
  • 2011
  • Ingår i: European Heart Journal. - : Oxford University Press (OUP). - 0195-668X .- 1522-9645. ; 32:23, s. 2945-2953
  • Tidskriftsartikel (refereegranskat)abstract
    • Aims To describe the incidence of dyspnoea and its associations with demographic characteristics and clinical outcomes in patients with acute coronary syndromes (ACS) treated with ticagrelor or clopidogrel in the PLATelet inhibition and patient Outcomes (PLATO) study. Methods and results In the PLATO study, 18 624 patients were randomized to receive either clopidogrel [300-600 mg loading dose (LD), 75 mg daily] or ticagrelor (180 mg LD, 90 mg b.i.d.). The occurrence of reported dyspnoea adverse events (AEs) was analysed in the 18 421 patients who received at least one dose of study medication in relation to demographic characteristics, clinical outcomes and other associations of patients with and without dyspnoea. A total of 1339 ticagrelor-treated patients (14.5%) and 798 clopidogrel-treated patients (8.7%) had a dyspnoea AE following randomization, with respectively 39 (0.4%) and 24 (0.3%) classified as severe in intensity. Excluding dyspnoea AEs occurring after the secondary endpoint of myocardial infarction (MI), the yearly rates of the efficacy endpoints in dyspnoea AE patients in the ticagrelor and clopidogrel groups were: for the primary composite of CV death, MI, and stroke, 8.8 and 10.4% (unadjusted P = 0.25; adjusted P = 0.54); for CV death, 3.1 and 4.8% (unadjusted P = 0.024; adjusted P = 0.18); and for total death 3.7 and 6.2% (unadjusted P = 0.004; adjusted P = 0.06), respectively. Conclusions Ticagrelor-related dyspnoea is usually mild or moderate in intensity and does not appear to be associated with differences concerning any efficacy or safety outcomes with ticagrelor compared with clopidogrel therapy in ACS patients.
  •  
6.
  • Storey, Robert F, et al. (författare)
  • Pulmonary function in patients with acute coronary syndrome treated with ticagrelor or clopidogrel (from the Platelet Inhibition and Patient Outcomes [PLATO] pulmonary function substudy)
  • 2011
  • Ingår i: American Journal of Cardiology. - : Elsevier BV. - 0002-9149 .- 1879-1913. ; 108:11, s. 1542-1546
  • Tidskriftsartikel (refereegranskat)abstract
    • The Platelet Inhibition and Patient Outcomes (PLATO) trial showed that ticagrelor reduced the risk for cardiovascular events in patients with acute coronary syndromes compared to clopidogrel but was associated with increased incidence of dyspnea. This substudy assessed whether ticagrelor affects pulmonary function in patients with acute coronary syndromes: 199 patients enrolled in the PLATO trial and receiving randomized treatment with ticagrelor 90 mg twice daily (n = 101) or clopidogrel 75 mg/day (n = 98) took part in the pulmonary function substudy. Patients with advanced lung disease, congestive heart failure, or coronary artery bypass graft surgery after the index event were excluded. Pulse oximetry (blood oxygen saturation), spirometry (forced expiratory volume in 1 second, forced vital capacity, and forced expiratory flow between 25% and 75% of forced vital capacity before and 20 minutes after inhalation of a β(2) agonist), lung volumes (total lung capacity, functional residual capacity, residual volume), and diffusion capacity were performed after patients received study medication for 30 to 40 days. Tests were then repeated <10 days before and approximately 30 days after the discontinuation of study medication. After a mean treatment duration of 31 days, there were no differences between the groups for any of the pulmonary function parameters. At the end of treatment (mean 211 days) and after the discontinuation of study medication (mean 32 days after the last dose), there was also no evidence of a change in pulmonary function in either group. For example, forced expiratory volume in 1 second values before β(2) agonist inhalation in the ticagrelor and clopidogrel groups were 2.81 ± 0.73 and 2.70 ± 0.84 L, respectively, at the first visit and did not change significantly at subsequent visits. In conclusion, no effect of ticagrelor on pulmonary function was seen in this cohort of patients with acute coronary syndromes compared to clopidogrel.
  •  
7.
  • Åkerblom, Axel, 1977-, et al. (författare)
  • Cystatin C and Estimated Glomerular Filtration Rate as Predictors for Adverse Outcome in Patients with ST-Elevation and Non-ST-Elevation Acute Coronary Syndromes : Results from the Platelet Inhibition and Patient Outcomes Study
  • 2012
  • Ingår i: Clinical Chemistry. - : Oxford University Press (OUP). - 0009-9147 .- 1530-8561. ; 58:1, s. 190-199
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND:We evaluated the predictive ability of cystatin C and creatinine-based estimations of glomerular filtration rate (eGFR), including the Chronic Kidney Disease-Epidemiology (CKD-EPI) equation, in acute coronary syndrome (ACS) patients with (STE-ACS) or without (NSTE-ACS) ST elevation in a large contemporary ACS population.METHODS:Concentrations of cystatin C and creatinine, as well as eGFR at randomization, were measured in 16 401 patients in the Platelet Inhibition and Patient Outcomes (PLATO) study and evaluated as predictors of the composite end point of cardiovascular death or myocardial infarction within 1 year. Two Cox proportional hazards models were used, the first adjusting for clinical characteristics and the second for clinical characteristics plus the biomarkers N-terminal pro-B-type natriuretic peptide, troponin I, and C-reactive protein.RESULTS:The median cystatin C value was 0.83 mg/L. Increasing quartiles of cystatin C were strongly associated with poor outcome (6.9%, 7.1%, 9.5%, and 16.2%). The fully adjusted hazard ratios per SD of cystatin C in the NSTE-ACS and STE-ACS populations were 1.12 (95% CI 1.04-1.20) (n = 8053) and 1.06 (95% CI 0.97-1.17) (n = 5278), respectively. There was no significant relationship of cystatin C with type of ACS (STE or NSTE). c Statistics ranged from 0.6923 (cystatin C) to 0.6941 (CKD-EPI).CONCLUSIONS:Cystatin C concentration contributes independently in predicting the risk of cardiovascular death or myocardial infarction in NSTE-ACS, with no interaction by type of ACS. CKD-EPI exhibited the largest predictive value of all renal markers. Nevertheless, the additive predictive value of cystatin C or creatinine-based eGFR measures in the unselected ACS patient is small.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7
Typ av publikation
tidskriftsartikel (7)
Typ av innehåll
refereegranskat (7)
Författare/redaktör
James, Stefan K., 19 ... (4)
James, Stefan, 1964- (3)
Wallentin, Lars, 194 ... (3)
Becker, Richard C. (3)
Husted, Steen (3)
Steg, Philippe Gabri ... (3)
visa fler...
Storey, Robert F. (3)
Katus, Hugo A (2)
Harrington, Robert A (2)
Cools, Frank (2)
Lagerqvist, Bo, 1952 ... (2)
Cannon, Christopher ... (2)
Fröbert, Ole (2)
Khurmi, Nardev S. (2)
Nilsson, Johan (1)
Albertsson, Per (1)
Omerovic, Elmir, 196 ... (1)
Ståhle, Elisabeth (1)
Koutouzis, Michael (1)
Lagerqvist, Bo (1)
Stenestrand, Ulf (1)
Emanuelsson, Håkan (1)
Mack, Michael J. (1)
Lindbäck, Johan (1)
Giannitsis, Evangelo ... (1)
Omerovic, Elmir (1)
Åkerblom, Axel, 1977 ... (1)
Serruys, Patrick W. (1)
Carlsson, Jörg (1)
Sarno, Giovanna (1)
Scherstén, Fredrik (1)
Matejka, Göran (1)
Horrow, Jay (1)
Budaj, Andrzej (1)
Olivecrona, Göran (1)
Dawkins, Keith D. (1)
Colombo, Antonio (1)
Holmes, David R. (1)
Morice, Marie-Claude (1)
Morel, Marie-Angele (1)
Nilsson, Tage (1)
Grip, Lars (1)
Saleh, Nawzad (1)
Mohr, Friedrich (1)
Kappetein, A. Pieter (1)
van den Brand, Marce ... (1)
Carrié, Didier (1)
Fournial, Gerard (1)
Emanuelsson, Hakan (1)
Åsenblad, Nils (1)
visa färre...
Lärosäte
Uppsala universitet (7)
Linköpings universitet (2)
Lunds universitet (2)
Göteborgs universitet (1)
Umeå universitet (1)
Karolinska Institutet (1)
Språk
Engelska (7)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (7)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy