SwePub
Sök i SwePub databas

  Utökad sökning

Booleska operatorer måste skrivas med VERSALER

AND är defaultoperator och kan utelämnas

Träfflista för sökning "AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) ;srt2:(2010-2014)"

Sökning: AMNE:(MEDICAL AND HEALTH SCIENCES Clinical Medicine Radiology, Nuclear Medicine and Medical Imaging) > (2010-2014)

  • Resultat 1-10 av 1547
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Petersson, Jesper, 1974 (författare)
  • Medicine At A Distance In Sweden: Spatiotemporal Matters In Accomplishing Working Telemedicine
  • 2011
  • Ingår i: Science Studies. - 0786-3012. ; 24:2, s. 43-62
  • Tidskriftsartikel (refereegranskat)abstract
    • This paper examines the accomplishment of making technology work, using the discourse around telemedicine in Swedish healthcare during 1994-2003. The paper will compare four projects launched in the mid-1990s and policymakers’ visions of healthcare through telemedicine. I will employ a sociotechnical approach developed within Actor-Network Theory that understands functioning technology not as something intrinsic but as an outcome of an ongoing process of negotiations. In the paper, I will extend the sociotechnical approach of what constitutes working technology to include spatiotemporal matters. I will also approach the closely related issue of space that has become a concern of Actor-Network Theory scholars interested in the accomplishment and continued workings of technology as it travels. In this discussion, an emphasis on fixed relations (network space) has been challenged by investigations into changing relations (fluid space). This paper suggests that in order to travel well, technology must be both fixed and fluid.⁰
  •  
3.
  • Chakarova, Roumiana, et al. (författare)
  • A Monte Carlo evaluation of beam characteristics for total body irradiation at extended treatment distances
  • 2014
  • Ingår i: Journal of Applied Clinical Medical Physics. - 1526-9914. ; 15:3, s. 182-189
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim is to study beam characteristics at large distances when focusing on the electron component. In particular, to investigate the utility of spoilers with various thicknesses as an electron source, as well as the effect of different spoiler-to-surface distances (STSD) on the beam characteristics and, consequently, on the dose in the superficial region. A MC model of a 15 MV Varian accelerator, validated earlier by experimental data at isocenter and extended distances used in large-field total body irradiation, is applied to evaluate beam characteristics at distances larger than 400 cm. Calculations are carried out using BEAMnrc/DOSXYZnrc code packages and phase space data are analyzed by the beam data processor BEAMdp. The electron component of the beam is analyzed at isocenter and extended distances, with and without spoilers as beam modifiers, assuming vacuum or air surrounding the accelerator head. Spoiler thickness of 1.6 cm is found to be optimal compared to thicknesses of 0.8 cm and 2.4 cm. The STSD variations should be taken into account when treating patients, in particular when the treatment protocols are based on a fixed distance to the patient central sagittal plane, and also, in order to maintain high dose in the superficial region.
  •  
4.
  • Rosendahl, Lene, et al. (författare)
  • Image quality and myocardial scar size determined with magnetic resonance imaging in patients with permanent atrial fibrillation : A comparison of two imaging protocols
  • 2010
  • Ingår i: Clinical Physiology and Functional Imaging. - : John Wiley & Sons. - 1475-0961 .- 1475-097X. ; 30:2, s. 122-129
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Magnetic resonance imaging (MRI) of the heart generally requires breath holding and a regular rhythm. Single shot 2D steady-state free precession (SS_SSFP) is a fast sequence insensitive to arrhythmia as well as breath holding. Our purpose was to determine image quality, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios and infarct size with a fast single shot and a standard segmented MRI sequence in patients with permanent atrial fibrillation and chronic myocardial infarction.Methods: Twenty patients with chronic myocardial infarction and ongoing atrial fibrillation were examined with inversion recovery SS_SSFP and segmented inversion recovery 2D fast gradient echo (IR_FGRE). Image quality was assessed in four categories: delineation of infarcted and non-infarcted myocardium, occurrence of artefacts and overall image quality. SNR and CNR were calculated. Myocardial volume (ml) and infarct size, expressed as volume (ml) and extent (%), were calculated, and the methodological error was assessed.Results: SS_SSFP had significantly better quality scores in all categories (P = 0·037, P = 0·014, P = 0·021, P = 0·03). SNRinfarct and SNRblood were significantly better for IR_FGRE than for SS_SSFP (P = 0·048, P = 0·018). No significant difference was found in SNRmyocardium and CNR. The myocardial volume was significantly larger with SS_SSFP (170·7 versus 159·2 ml, P<0·001), but no significant difference was found in infarct volume and infarct extent.Conclusion: SS_SSFP displayed significantly better image quality than IR_FGRE. The infarct size and the error in its determination were equal for both sequences, and the examination time was shorter with SS_SSFP.
  •  
5.
  • Reza, Salim, 1985-, et al. (författare)
  • Smart dosimetry by pattern recognition using a single photon counting detector system in time over threshold mode
  • 2012
  • Ingår i: Journal of Instrumentation. - 1748-0221. ; 7:1
  • Tidskriftsartikel (refereegranskat)abstract
    • The function of a dosimeter is to determine the absorbed dose of radiation, for those cases in which, generally, the particular type of radiation is already known. Lately, a number of applications have emerged in which all kinds of radiation are absorbed and are sorted by pattern recognition, such as the Medipix2 application in [1]. This form of smart dosimetry enables measurements where not only the total dosage is measured, but also the contributions of different types of radiation impacting upon the detector surface. Furthermore, the use of a photon counting system, where the energy deposition can be measured in each individual pixel, ensures measurements with a high degree of accuracy in relation to the pattern recognition. In this article a Timepix [2] detector system has been used in the creation of a smart dosimeter for Alpha, Beta and Gamma radiation. When a radioactive particle hits the detector surface it generates charge clusters and those impacting upon the detector surface are read out and image processing algorithms are then used to classify each charge cluster. The individual clusters are calculated and as a result, the dosage for each type of radiation is given. In some cases, several particles can impact in roughly the same place, forming overlapping clusters. In order to handle this problem, a cluster separation method has been added to the pattern recognition algorithm. When the clusters have been separated, they are classified by shape and sorted into the correct type of radiation. The algorithms and methods used in this dosimeter have been developed so as to be simple and computationally effective, in order to enable implementation on a portable device. © 2012 IOP Publishing Ltd and SISSA.
  •  
6.
  • Sarve, Hamid, et al. (författare)
  • Extracting 3D information on bone remodeling in the proximity of titanium implants in SRμCT image volumes.
  • 2011
  • Ingår i: Computer methods and programs in biomedicine. - : Elsevier BV. - 1872-7565 .- 0169-2607. ; 102:1, s. 25-34
  • Tidskriftsartikel (refereegranskat)abstract
    • Bone-implant integration is measured in several ways. Traditionally and routinely, 2D histological sections of samples, containing bone and the biomaterial, are stained and analyzed using a light microscope. Such histological section provides detailed cellular information about the bone regeneration in the proximity of the implant. However, this information reflects the integration in only a very small fraction, a 10 μm thick slice, of the sample. In this study, we show that feature values quantified on 2D sections are highly dependent on the orientation and the placement of the section, suggesting that a 3D analysis of the whole sample is of importance for a more complete judgment of the bone structure in the proximity of the implant. We propose features describing the 3D data by extending the features traditionally used for 2D-analysis. We present a method for extracting these features from 3D image data and we measure them on five 3D SRμCT image volumes. We also simulate cuts through the image volume positioned at all possible section positions. These simulations show that the measurement variations due to the orientation of the section around the center line of the implant are about 30%.
  •  
7.
  • Björkman, Kristoffer, et al. (författare)
  • Genotype-phenotype correlations in patients with complex I deficiency due to mutations in NDUFS1 and NDUFV1
  • 2014
  • Ingår i: Euromit 2014, 15-19 juni, Tampere, Finland.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)abstract
    • Objectives: To study genotype-phenotype correlations in genes encoding complex I electron input module subunits. Materials and methods: We studied five patients with isolated complex I deficiency, three with NDUFS1 mutations and two with NDUFV1 mutations. A literature review of all reported cases of mutations in the affected genes was performed. Results: The literature review revealed pathological mutations in NDUFS1 for 18 patients in 17 families and correspondingly in NDUFV1 for 26 patients in 19 families. Unpublished clinical data for our five patients were added. Our study showed quite variable clinical courses; death before two years of age was seen in 41% of patients while 18% were alive at seven years. There was a significant difference between the NDUFS1 and NDUFV1 groups for clinical onset and life-span. Mutations in NDUFS1 were linked to a worse clinical course with earlier onset and earlier death. Conclusions: Genotype-phenotype correlations in patients with mutations affecting the genes that encode the electron input module of complex I vary, but patients with NDUFS1 mutation tend to have a worse clinical course than patients with NDUFV1 mutation. Identifying the mutations is of importance for accurate prognostic information and genetic counseling.
  •  
8.
  •  
9.
  • Wang, Chunliang, 1980-, et al. (författare)
  • Integrating automatic and interactive method for coronary artery segmentation : let PACS workstation think ahead
  • 2010
  • Ingår i: International Journal of Computer Assisted Radiology and Surgery. - : Springer Science and Business Media LLC. - 1861-6410 .- 1861-6429. ; 5:3, s. 275-285
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To provide an efficient method to extract useful information from the increasing amount of coronary CTA.Methods: A quantitative coronary CTA analysis tool was built on OsiriX, which integrates both fully automatic and interactive methods for coronary artery extraction. The computational power of an ordinary PC is exploited by running the non-supervised coronary artery segmentation and centerline tracking in the background as soon as the images are received. When the user opens the data, the software provides a real-time interactive analysis environment.Results: The average overlap between the centerline created in our software and the reference standard was 96.0%. The average distance between them was 0.38 mm. The automatic procedure runs for 3-5 min as a single-thread application in background. Interactive processing takes 3 min in average.Conclusion: In preliminary experiments, the software achieved higher efficiency than the former interactive method, and reasonable accuracy compared to manual vessel extraction.
  •  
10.
  • Tolmachev, Vladimir, et al. (författare)
  • Imaging of EGFR expression in murine xenografts using site-specifically labelled anti-EGFR In-111-DOTA-Z(EGFR:2377) Affibody molecule : aspect of the injected tracer amount
  • 2010
  • Ingår i: European Journal of Nuclear Medicine and Molecular Imaging. - : Springer Science and Business Media LLC. - 1619-7070 .- 1619-7089. ; 37:3, s. 613-622
  • Tidskriftsartikel (refereegranskat)abstract
    • Overexpression of epidermal growth factor receptor (EGFR) is a prognostic and predictive biomarker in a number of malignant tumours. Radionuclide molecular imaging of EGFR expression in cancer could influence patient management. However, EGFR expression in normal tissues might complicate in vivo imaging. The aim of this study was to evaluate if optimization of the injected protein dose might improve imaging of EGFR expression in tumours using a novel EGFR-targeting protein, the DOTA-Z(EGFR:2377) Affibody molecule. An anti-EGFR Affibody molecule, Z(EGFR:2377), was labelled with In-111 via the DOTA chelator site-specifically conjugated to a C-terminal cysteine. The affinity of DOTA-Z(EGFR:2377) for murine and human EGFR was measured by surface plasmon resonance. The cellular processing of In-111-DOTA-Z(EGFR:2377) was evaluated in vitro. The biodistribution of radiolabelled Affibody molecules injected in a broad range of injected Affibody protein doses was evaluated in mice bearing EGFR-expressing A431 xenografts. Site-specific coupling of DOTA provided a uniform conjugate possessing equal affinity for human and murine EGFR. The internalization of In-111-DOTA-Z(EGFR:2377) by A431 cells was slow. In vivo, the conjugate accumulated specifically in xenografts and in EGFR-expressing tissues. The curve representing the dependence of tumour uptake on the injected Affibody protein dose was bell-shaped. The highest specific radioactivity (lowest injected protein dose) provided a suboptimal tumour-to-blood ratio. The results of the biodistribution study were confirmed by gamma-camera imaging. The In-111-DOTA-Z(EGFR:2377) Affibody molecule is a promising tracer for radionuclide molecular imaging of EGFR expression in malignant tumours. Careful optimization of protein dose is required for high-contrast imaging of EGFR expression in vivo.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 1547
Typ av publikation
tidskriftsartikel (1094)
konferensbidrag (295)
doktorsavhandling (65)
forskningsöversikt (32)
bokkapitel (29)
rapport (8)
visa fler...
annan publikation (6)
patent (6)
licentiatavhandling (4)
bok (3)
samlingsverk (redaktörskap) (2)
proceedings (redaktörskap) (2)
konstnärligt arbete (1)
recension (1)
visa färre...
Typ av innehåll
refereegranskat (1213)
övrigt vetenskapligt/konstnärligt (326)
populärvet., debatt m.m. (8)
Författare/redaktör
Forssell-Aronsson, E ... (113)
Båth, Magnus, 1974 (68)
Helou, Khalil, 1966 (55)
Mattsson, Sören (51)
Langen, Britta (37)
Valentin, Lil (36)
visa fler...
Schüler, Emil (36)
Tolmachev, Vladimir (34)
Lubberink, Mark (33)
Söderberg, Marcus (32)
Ståhlberg, Freddy (32)
Spetz, Johan (30)
Johnsson, Åse (Allan ... (28)
Orlova, Anna (27)
Svalkvist, Angelica (26)
Wängberg, Bo, 1953 (24)
Nilsson, Ola, 1957 (24)
Bernhardt, Peter, 19 ... (24)
Strand, Sven-Erik (23)
Wirestam, Ronnie (23)
Tingberg, Anders (23)
Borga, Magnus (22)
Sundgren, Pia (22)
Ljungberg, Michael (22)
Danielsson, Mats (22)
Ljungberg, Maria (22)
Vikgren, Jenny, 1957 (22)
van Westen, Danielle (21)
Timmerman, D. (21)
Bech, Martin (21)
Lindegren, Sture, 19 ... (19)
Nyman, Ulf (19)
Nilsson, Markus (18)
Dahlqvist Leinhard, ... (18)
Bäck, Tom, 1964 (18)
Testa, A. C. (18)
Dalmo, Johanna (18)
Zackrisson, Sophia (17)
Knutsson, Linda (17)
Palm, Stig, 1964 (17)
Geijer, Mats (16)
Sandström, Mattias (16)
Van Holsbeke, C (16)
Ahlman, Håkan, 1947 (15)
Rystedt, Hans, 1951 (15)
Björkman-Burtscher, ... (15)
Bornefalk, Hans (15)
Jensen, Holger (15)
Leide-Svegborn, Sigr ... (15)
Domanski, Henryk (15)
visa färre...
Lärosäte
Lunds universitet (620)
Göteborgs universitet (378)
Uppsala universitet (212)
Karolinska Institutet (194)
Umeå universitet (119)
Linköpings universitet (112)
visa fler...
Kungliga Tekniska Högskolan (110)
Stockholms universitet (83)
Chalmers tekniska högskola (32)
Örebro universitet (28)
Sveriges Lantbruksuniversitet (16)
Malmö universitet (9)
Jönköping University (4)
Luleå tekniska universitet (3)
Mittuniversitetet (3)
Linnéuniversitetet (3)
RISE (2)
Högskolan i Halmstad (1)
Högskolan i Gävle (1)
Mälardalens universitet (1)
Handelshögskolan i Stockholm (1)
Högskolan i Skövde (1)
Gymnastik- och idrottshögskolan (1)
Karlstads universitet (1)
Högskolan Dalarna (1)
visa färre...
Språk
Engelska (1515)
Svenska (30)
Tyska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (1547)
Naturvetenskap (98)
Teknik (88)
Samhällsvetenskap (29)
Lantbruksvetenskap (7)
Humaniora (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy