SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0161 5505 OR L773:1535 5667 srt2:(2020-2024)"

Sökning: L773:0161 5505 OR L773:1535 5667 > (2020-2024)

  • Resultat 1-10 av 58
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Alhuseinalkhudhur, Ali, et al. (författare)
  • Human Epidermal Growth Factor Receptor 2-Targeting [68Ga]Ga-ABY-025 PET/CT Predicts Early Metabolic Response in Metastatic Breast Cancer.
  • 2023
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667. ; 64:9, s. 1364-1370
  • Tidskriftsartikel (refereegranskat)abstract
    • Imaging using the human epidermal growth factor receptor 2 (HER2)-binding tracer 68Ga-labeled ZHER2:2891-Cys-MMA-DOTA ([68Ga]Ga-ABY-025) was shown to reflect HER2 status determined by immunohistochemistry and in situ hybridization in metastatic breast cancer (MBC). This single-center open-label phase II study investigated how [68Ga]Ga-ABY-025 uptake corresponds to biopsy results and early treatment response in both primary breast cancer (PBC) planned for neoadjuvant chemotherapy and MBC. Methods: Forty patients with known positive HER2 status were included: 19 with PBC and 21 with MBC (median, 3 previous treatments). [68Ga]Ga-ABY-025 PET/CT, [18F]F-FDG PET/CT, and core-needle biopsies from targeted lesions were performed at baseline. [18F]F-FDG PET/CT was repeated after 2 cycles of therapy to calculate the directional change in tumor lesion glycolysis (Δ-TLG). The largest lesions (up to 5) were evaluated in all 3 scans per patient. SUVs from [68Ga]Ga-ABY-025 PET/CT were compared with the biopsied HER2 status and Δ-TLG by receiver operating characteristic analyses. Results: Trial biopsies were HER2-positive in 31 patients, HER2-negative in 6 patients, and borderline HER2-positive in 3 patients. The [68Ga]Ga-ABY-025 PET/CT cutoff SUVmax of 6.0 predicted a Δ-TLG lower than -25% with 86% sensitivity and 67% specificity in soft-tissue lesions (area under the curve, 0.74 [95% CI, 0.67-0.82]; P = 0.01). Compared with the HER2 status, this cutoff resulted in clinically relevant discordant findings in 12 of 40 patients. Metabolic response (Δ-TLG) was more pronounced in PBC (-71% [95% CI, -58% to -83%]; P < 0.0001) than in MBC (-27% [95% CI, -16% to -38%]; P < 0.0001), but [68Ga]Ga-ABY-025 SUVmax was similar in both with a mean SUVmax of 9.8 (95% CI, 6.3-13.3) and 13.9 (95% CI, 10.5-17.2), respectively (P = 0.10). In multivariate analysis, global Δ-TLG was positively associated with the number of previous treatments (P = 0.0004) and negatively associated with [68Ga]Ga-ABY-025 PET/CT SUVmax (P = 0.018) but not with HER2 status (P = 0.09). Conclusion: [68Ga]Ga-ABY-025 PET/CT predicted early metabolic response to HER2-targeted therapy in HER2-positive breast cancer. Metabolic response was attenuated in recurrent disease. [68Ga]Ga-ABY-025 PET/CT appears to provide an estimate of the HER2 expression required to induce tumor metabolic remission by targeted therapies and might be useful as an adjunct diagnostic tool.
  •  
2.
  • Anand, Aseem, et al. (författare)
  • Assessing Radiographic Response to 223Ra with an Automated Bone Scan Index in Metastatic Castration-Resistant Prostate Cancer Patients
  • 2020
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 2159-662X .- 1535-5667. ; 61:5, s. 671-675
  • Tidskriftsartikel (refereegranskat)abstract
    • For effective clinical management of patients being treated with 223Ra, there is a need for radiographic response biomarkers to minimize disease progression and to stratify patients for subsequent treatment options. The objective of this study was to evaluate an automated bone scan index (aBSI) as a quantitative assessment of bone scans for radiographic response in patients with metastatic castration-resistant prostate cancer (mCRPC). Methods: In a multicenter retrospective study, bone scans from patients with mCRPC treated with monthly injections of 223Ra were collected from 7 hospitals in Sweden. Patients with available bone scans before treatment with 223Ra and at treatment discontinuation were eligible for the study. The aBSI was generated at baseline and at treatment discontinuation. The Spearman rank correlation was used to correlate aBSI with the baseline covariates: alkaline phosphatase (ALP) and prostate-specific antigen (PSA). The Cox proportional-hazards model and Kaplan-Meier curve were used to evaluate the association of covariates at baseline and their change at treatment discontinuation with overall survival (OS). The concordance index (C-index) was used to evaluate the discriminating strength of covariates in predicting OS. Results: Bone scan images at baseline were available from 156 patients, and 67 patients had both a baseline and a treatment discontinuation bone scan (median, 5 doses; interquartile range, 3-6 doses). Baseline aBSI (median, 4.5; interquartile range, 2.4-6.5) was moderately correlated with ALP (r = 0.60, P < 0.0001) and with PSA (r = 0.38, P = 0.003). Among baseline covariates, aBSI (P = 0.01) and ALP (P = 0.001) were significantly associated with OS, whereas PSA values were not (P = 0.059). After treatment discontinuation, 36% (24/67), 80% (54/67), and 13% (9/67) of patients demonstrated a decline in aBSI, ALP, and PSA, respectively. As a continuous variable, the relative change in aBSI after treatment, compared with baseline, was significantly associated with OS (P < 0.0001), with a C-index of 0.67. Median OS in patients with both aBSI and ALP decline (median, 134 wk) was significantly longer than in patients with ALP decline only (median, 77 wk; P = 0.029). Conclusion: Both aBSI at baseline and its change at treatment discontinuation were significant parameters associated with OS. The study warrants prospective validation of aBSI as a quantitative imaging response biomarker to predict OS in patients with mCRPC treated with 223Ra.
  •  
3.
  • Antoni, Gunnar, et al. (författare)
  • In Vivo Visualization and Quantification of Neutrophil Elastase in Lungs of COVID-19 Patients : A First-in-Humans PET Study with 11C-NES
  • 2023
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 64:1, s. 145-148
  • Tidskriftsartikel (refereegranskat)abstract
    • COVID-19 can cause life-threatening lung-inflammation that is suggested to be mediated by neutrophils, whose effector mechanisms in COVID-19 is inexplicit. The aim of the present work is to evaluate a novel PET tracer for neutrophil elastase in COVID-19 patients and healthy controls.METHODS: In this open-label, First-In-Man study, four patients with hypoxia due to COVID-19 and two healthy controls were investigated with positron emission tomography (PET) using the new selective and specific neutrophil elastase PET-tracer [11C]GW457427 and [15O]water for the visualization and quantification of NE and perfusion in the lungs, respectively.RESULTS: [11C]GW457427 accumulated selectively in lung areas with ground-glass opacities on computed tomography characteristic of COVID-19 suggesting high levels on NE in these areas. In the same areas perfusion was severely reduced in comparison to healthy lung tissue as measured with [15O]water.CONCLUSION: The data suggests that NE may be responsible for the severe lung inflammation in COVID-19 patients and that inhibition of NE could potentially reduce the acute inflammatory process and improve the condition.
  •  
4.
  • Boccalini, Cecilia, et al. (författare)
  • Early-Phase 18F-Florbetapir and 18F-Flutemetamol Images as Proxies of Brain Metabolism in a Memory Clinic Setting
  • 2023
  • Ingår i: Journal of Nuclear Medicine. - : The Society of Nuclear Medicine and Molecular Imaging. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 64:2, s. 266-273
  • Tidskriftsartikel (refereegranskat)abstract
    • Alzheimer disease (AD) neuropathologic changes are 6-amyloid (A6) deposition, pathologic tau, and neurodegeneration. Dual-phase amy-loid PET might be able to evaluate A6 deposition and neurodegenera-tion with a single tracer injection. Early-phase amyloid PET scans provide a proxy for cerebral perfusion, which has shown good correla-tions with neural dysfunction measured through metabolic consump-tion, whereas the late frames depict amyloid distribution. Our study aimed to assess the comparability between early-phase amyloid PET scans and 18F-FDG PET brain topography at the individual level and their ability to discriminate patients. Methods: One hundred sixty-six subjects evaluated at the Geneva Memory Center, ranging from no cognitive impairment to mild cognitive impairment and dementia, underwent early-phase amyloid PET-using either 18F-florbetapir (eFBP) (n = 94) or 18F-flutemetamol (eFMM) (n = 72)-and 18F-FDG PET. A6 status was assessed. SUV ratios (SUVRs) were extracted to evaluate the correlation of eFBP/eFMM and their respective 18F-FDG PET scans. The single-subject procedure was applied to investigate hypometabolism and hypoperfusion maps and their spatial overlap by the Dice coefficient. Receiver-operating-characteristic analyses were performed to compare the discriminative power of eFBP/eFMM and 18F-FDG PET SUVR in AD-related meta-regions of interest between A6-negative healthy controls and cases in the AD continuum. Results: Positive correlations were found between eFBP/eFMM and 18F-FDG PET SUVR independently of A6 status and A6 radiotracer (R> 0.72, P< 0.001). eFBP/eFMM single-subject analysis revealed clusters of significant hypoperfusion with good correspondence to hypometabo-lism topographies, independently of the underlying neurodegenerative patterns. Both eFBP/eFMM and 18F-FDG PET SUVR significantly dis-criminated AD patients from controls in the AD-related meta-regions of interest (eFBP area under the curve [AUC], 0.888; eFMM AUC, 0.801), with 18F-FDG PET performing slightly better, although not sig-nificantly (all P values higher than 0.05), than others (18F-FDG AUC, 0.915 and 0.832 for subjects evaluated with eFBP and eFMM, respec-tively). Conclusion: The distribution of perfusion was comparable to that of metabolism at the single-subject level by parametric analysis, particularly in the presence of a high neurodegeneration burden. Our findings indicate that eFBP and eFMM imaging can replace 18F-FDG PET imaging, as they reveal typical neurodegenerative patterns or allow exclusion of the presence of neurodegeneration. The findings show cost-saving capacities of amyloid PET and support routine use of the modality for individual classification in clinical practice.
  •  
5.
  • Bragina, Olga, et al. (författare)
  • Phase I study of 99mTc-ADAPT6, a scaffold protein-based probe for visualization of HER2 expression in breast cancer
  • 2021
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 62:4, s. 493-499
  • Tidskriftsartikel (refereegranskat)abstract
    • Radionuclide molecular imaging of human epidermal growth factor (HER2) expression may be helpful to stratify breast and gastroesophageal cancer patients for HER2-targeting therapies. ADAPTs (albumin-binding domain derived affinity proteins) are a new type of small (46-59 amino acids) proteins useful as probes for molecular imaging. The aim of this first-in-human study was to evaluate biodistribution, dosimetry, and safety of the HER2-specific 99mTc-ADAPT6.METHODS: Twenty-nine patients with primary breast cancerwere included. In 22 patients with HER2-positive (n = 11) or HER2-negative (n = 11) histopathology an intravenous injection with 385±125 MBq 99mTc-ADAPT6 was performed, randomized to an injected protein mass of either 500 µg (n = 11) or 1000 µg (n = 11). Planar scintigraphy followed by SPECT imaging was performed after 2, 4, 6 and 24 h. An additional cohort (n = 7) was injected with 165±29 MBq (injected protein mass 250 µg) and imaging was performed after 2 h only.RESULTS: Injections of 99mTc-ADAPT6 at all injected mass levels were well tolerated and not associated with adverse effects. 99mTc-ADAPT6 cleared rapidly from blood and most other tissues. The normal organs with the highest accumulation were kidney, liver and lung. Effective doses were 0.009±0.002 and 0.010±0.003 mSv/MBq for injected protein masses of 500 and 1000 µg, respectively. Injection of 500 µg resulted in excellent discrimination between HER2-positive and HER2-negative tumors already 2 h after injection (tumor-to-contralateral breast ratio was 37±19 vs 5±2, p<0.01). The tumor-to-contralateral breast ratios for HER2-positive tumors were significantly (p<0.05) higher for injected mass of 500 µg than for both 250 and 1000 µg.CONCLUSION: Injections of 99mTc-ADAPT6 are safe and associated with low absorbed and effective doses. Protein dose of 500 µg is preferable for discrimination between tumors with high and low expression of HER2. Further studies are justified to evaluate if 99mTc-ADAPT6 can be used as an imaging probe for stratification of patients for HER2-targeting therapy in the areas where PET imaging is not readily available.
  •  
6.
  • Bragina, Olga, et al. (författare)
  • Phase I Trial of 99mTc-(HE)3-G3, a DARPin-Based Probe for Imaging of HER2 Expression in Breast Cancer
  • 2022
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 63:4, s. 528-535
  • Tidskriftsartikel (refereegranskat)abstract
    • Radionuclide molecular imaging of human epidermal growth factor receptor type 2 (HER2) expression may enable a noninvasive discrimination between HER2-positive and HER2-negative breast cancers for stratification of patients for HER2-targeted treatments. DARPin (designed ankyrin repeat proteins) G3 is a small (molecular weight, 14 kDa) scaffold protein with picomolar affinity to HER2. The aim of this first-in-humans study was to evaluate the safety, biodistribution, and dosimetry of 99mTc-(HE)3-G3.Methods: Three cohorts of patients with primary breast cancer (each including at least 4 patients with HER2-negative and 5 patients with HER2-positive tumors) were injected with 1,000, 2,000, or 3,000 μg of 99mTc-(HE)3-G3 (287 ± 170 MBq). Whole-body planar imaging followed by SPECT was performed at 2, 4, 6, and 24 h after injection. Vital signs and possible side effects were monitored during imaging and up to 7 d after injection.Results: All injections were well tolerated. No side effects were observed. The results of blood and urine analyses did not differ before and after studies. 99mTc-(HE)3-G3 cleared rapidly from the blood. The highest uptake was detected in the kidneys and liver followed by the lungs, breasts, and small intestinal content. The hepatic uptake after injection of 2,000 or 3,000 μg was significantly (P < 0.05) lower than the uptake after injection of 1,000 μg. Effective doses did not differ significantly between cohorts (average, 0.011 ± 0.004 mSv/MBq). Tumor–to–contralateral site ratios for HER-positive tumors were significantly (P < 0.05) higher than for HER2-negative at 2 and 4 h after injection.Conclusion: Imaging of HER2 expression using 99mTc-(HE)3-G3 is safe and well tolerated and provides a low absorbed dose burden on patients. This imaging enables discernment of HER2-positive and HER2-negative breast cancer. Phase I study data justify further clinical development of 99mTc-(HE)3-G3.
  •  
7.
  •  
8.
  • Eriksson, Olof, et al. (författare)
  • Glucagonlike Peptide-1 Receptor Imaging in Individuals with Type 2 Diabetes
  • 2022
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 63:5, s. 794-800
  • Tidskriftsartikel (refereegranskat)abstract
    • The glucagonlike peptide-1 receptor (GLP1R) is a gut hormone receptor, intricately linked to regulation of blood glucose homeostasis via several mechanisms. It is an established and emergent drug target in metabolic disease. The PET radioligand 68Ga-DO3A-VS-exendin4 (68Ga-exendin4) has the potential to enable longitudinal studies of GLP1R in the human pancreas.Methods: 68Ga-exendin4 PET/CT examinations were performed on overweight-to-obese individuals with type 2 diabetes (n = 13) as part of a larger target engagement study (NCT03350191). A scanning protocol was developed to optimize reproducibility (target amount of 0.5 MBq/kg [corresponding to peptide amount of <0.2 µg/kg], blood sampling, and tracer stability assessment). The pancreas and abdominal organs were segmented, and binding was correlated with clinical parameters.Results: Uptake of 68Ga-exendin4 in the pancreas, but not in other abdominal tissues, was high but variable between individuals. There was no evidence of self-blocking of GLP1R by the tracer in this protocol, despite the high potency of exendin4. The results showed that a full dynamic scan can be simplified to a short static scan, potentially increasing throughput and reducing patient discomfort. The 68Ga-exendin4 concentration in the pancreas (i.e., GLP1R density) correlated inversely with the age of the individual and tended to correlate positively with body mass index. However, the total GLP1R content in the pancreas did not.Conclusion: In summary, we present an optimized and simplified 68Ga-exendin4 scanning protocol to enable reproducible imaging of GLP1R in the pancreas. 68Ga-exendin4 PET may enable quantification of longitudinal changes in pancreatic GLP1R during the development of type 2 diabetes, as well as target engagement studies of novel glucagonlike peptide-1 agonists.
  •  
9.
  • Eriksson, Olof, et al. (författare)
  • Imaging of the Glucagon Receptor in Subjects with Type 2 Diabetes
  • 2021
  • Ingår i: Journal of Nuclear Medicine. - : SOC NUCLEAR MEDICINE INC. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 62:6, s. 833-838
  • Tidskriftsartikel (refereegranskat)abstract
    • Despite the importance of the glucagon receptor (GCGR) in disease and in pharmaceutical drug development, there is a lack of specific and sensitive biomarkers of its activation in humans. The PET radioligand Ga-68-DO3A-VS-Tuna-2 (Ga-68-Tuna-2) was developed to yield a noninvasive imaging marker for GCGR target distribution and drug target engagement in humans. Methods: The biodistribution and dosimetry of Ga-68-Tuna-2 was assessed by PET/CT in 13 individuals with type 2 diabetes as part of a clinical study assessing the occupancy of the dual GCGR/glucagon like peptide-1 receptor agonist SAR425899. Binding of Ga-68-Tuna-2 in liver and reference tissues was evaluated and correlated to biometrics (e.g., weight or body mass index) or other biomarkers (e.g., plasma glucagon levels). Results: Ga-68-Tuna-2 binding was seen primarily in the liver, which is in line with the strong expression of GCGR on hepatocytes. The kidneys demonstrated high excretion-related retention, whereas all other tissue demonstrated rapid washout. The SUV55 (min) (SUV during the last 10-min time frame, 50-60 min after administration) uptake endpoint was sensitive to endogenous levels of glucagon. Ga-68-Tuna-2 exhibited a safe dosimetry profile and no adverse events after intravenous administration. Conclusion: Ga-68-Tuna-2 can be used for safe and accurate assessment of the GCGR in human. It may serve as an important tool in understanding the in vivo pharmacology of novel drugs engaging the GCGR.
  •  
10.
  • Ilan, Ezgi, et al. (författare)
  • Tumor-to-blood ratio for assessment of somatostatin receptor density in neuroendocrine tumors using 68Ga-DOTATOC and 68Ga-DOTATATE.
  • 2020
  • Ingår i: Journal of Nuclear Medicine. - : Society of Nuclear Medicine. - 0161-5505 .- 1535-5667 .- 2159-662X. ; 61:2, s. 217-221
  • Tidskriftsartikel (refereegranskat)abstract
    • PET/CT with 68Ga-DOTA-somatostatin analogs has been tested for therapy monitoring in patients with neuroendocrine tumors (NETs). However, standardized uptake values (SUV) in tumors do not correlate with the net influx rate (Ki), as a representation of the somatostatin receptor (SSTR) expression. In this study, tumor-to-blood-ratio (TBR) was evaluated as an alternative tool for semi-quantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake and as a therapy monitoring tool for patients with NETs. Methods: Twenty-two NET patients underwent a 45-min dynamic PET/CT scan after injection of 68Ga-DOTATOC and/or 68Ga-DOTATATE. Ki was determined using the Patlak method and TBR was calculated for the 40-45 min time interval. Results: A linear relation was found between Ki and TBR, with a square of Pearson correlation (R2) of 0.98 and 0.93 for 68Ga-DOTATOC and 68Ga-DOTATATE, respectively. Conclusion: High correlation was found between Ki and TBR. Hence, TBR reflects SSTR density more accurately than SUV and is suggested as the preferred metrics for semi-quantitative assessment of 68Ga-DOTATOC and 68Ga-DOTATATE tumor uptake.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 58
Typ av publikation
tidskriftsartikel (48)
konferensbidrag (10)
Typ av innehåll
refereegranskat (46)
övrigt vetenskapligt/konstnärligt (12)
Författare/redaktör
Edenbrandt, Lars (8)
Enqvist, Olof, 1981 (8)
Bernhardt, Peter, 19 ... (6)
Sörensen, Jens (5)
Tolmachev, Vladimir (5)
Velikyan, Irina, 196 ... (5)
visa fler...
Antoni, Gunnar (4)
Halldin, C (4)
Ulén, Johannes (4)
Rydén, Tobias (4)
Axelsson, R (4)
Eriksson, Olof (4)
Nag, S (4)
Lubberink, Mark (4)
Ossenkoppele, Rik (4)
Arakawa, R (4)
Varrone, A (3)
af Buren, S (3)
Tran, TA (3)
Sandström, Mattias (3)
Vorobyeva, Anzhelika (3)
Svensson, Johanna (3)
Sundin, Anders, 1954 ... (3)
Johansson, Lars (2)
Zhang, L. (2)
Choi, J. (2)
Abou, Diane S. (2)
Benabdallah, Nadia (2)
Ulmert, David (2)
Simons, Brian W. (2)
Thorek, Daniel L.J. (2)
Orlova, Anna, 1960- (2)
Chernov, Vladimir (2)
Orlova, Anna (2)
Zelchan, Roman (2)
Trägårdh, Elin (2)
Holstensson, M (2)
Altena, R (2)
Hansson, Oskar (2)
van der Flier, Wiesj ... (2)
Nilsson, T (2)
Bäck, Tom, 1964 (2)
Tillner, Joachim (2)
Kindblom, Jon, 1969 (2)
Medvedeva, Anna (2)
Takano, A (2)
Pike, VW (2)
Gauthier, S (2)
Elgland, Mathias (2)
Sigfridsson, Jonatha ... (2)
visa färre...
Lärosäte
Uppsala universitet (16)
Karolinska Institutet (15)
Göteborgs universitet (12)
Lunds universitet (11)
Chalmers tekniska högskola (8)
Kungliga Tekniska Högskolan (3)
visa fler...
Umeå universitet (1)
visa färre...
Språk
Engelska (58)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (45)
Naturvetenskap (9)
Teknik (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy