SwePub
Tyck till om SwePub Sök här!
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0168 8278 OR L773:1600 0641 srt2:(1990-1994)"

Sökning: L773:0168 8278 OR L773:1600 0641 > (1990-1994)

  • Resultat 1-2 av 2
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Friman, Styrbjörn, 1948, et al. (författare)
  • Biliary excretion of different sized polyethylene glycols in the cat.
  • 1990
  • Ingår i: Journal of hepatology. - 0168-8278. ; 11:2, s. 215-20
  • Tidskriftsartikel (refereegranskat)abstract
    • Polyethylene glycol (PEG) 900 is excreted more extensively into bile than mannitol and erythritol. In this study, the biliary recovery of intravenously injected marker molecules was analysed in anaesthetised cats with ligated renal pedicles. It was demonstrated that among polyethylene glycols sized 292-1250 Da, the species sized 1074 Da was maximally excreted in the bile. After 5 h, about 12% of the injected amount of this molecular species was recovered in bile. Both larger and smaller polyethylene glycol molecules had a lower biliary excretion. The distribution of different sized PEGs in the range 766-1250 Da in serum was fairly constant and cannot explain the recovery profile in bile. 14C-Labelled mannitol was recovered in bile to the extent of 0.7% of the amount given i.v. after 5 h, a figure that corresponds to that obtained for polyethylene glycol with a size of 370 Da. Bile/plasma ratios during steady state conditions of labelled PEG 450, PEG 900, PEG 2500 and PEG 4000 were 10, 36, 3 and 4, respectively. The results may be tentatively explained by restricted passage of the larger PEG molecules into the canaliculi, and leakage of the smaller molecules from bile back to plasma.
  •  
2.
  • Friman, Styrbjörn, 1948, et al. (författare)
  • Hepatic excretion and metabolism of polyethylene glycols and mannitol in the cat.
  • 1993
  • Ingår i: Journal of hepatology. - 0168-8278. ; 17:1, s. 48-55
  • Tidskriftsartikel (refereegranskat)abstract
    • The biliary clearances of fluid phase markers like erythritol and mannitol have been used to estimate canalicular bile flow. Larger fluid phase marker molecules like polyethylene glycol (PEG) 900 are excreted more extensively into bile, and it has been suggested that the biliary clearance of these give a more accurate measure of canalicular water flux than those of erythritol and mannitol. In this study, the biliary excretion of PEG 900 was compared with that of mannitol during choleresis induced by either sodium taurocholate or secretin. The biliary excretion of PEG 900 exceeded that of mannitol by a factor of 94. The biliary clearance of these markers was not influenced by secretin-induced choleresis. Using ion-exchange chromatography and fast atom bombardment mass spectrometry (FABMS) it was demonstrated that 26% of the PEG molecules are excreted into bile after oxidation to carboxylic acids, whereas sulphate conjugation is negligible. The majority of the PEG molecules (74%) were secreted unchanged, which supports the hypothesis of a mainly passive movement of PEG with the water flux into bile. FABMS showed an enrichment of larger PEG molecules in bile, which supports a previous finding that among differently sized PEGs the 1074-Da molecules have the highest biliary excretion.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-2 av 2
Typ av publikation
tidskriftsartikel (2)
Typ av innehåll
refereegranskat (2)
Författare/redaktör
Friman, Styrbjörn, 1 ... (2)
Svanvik, Joar, 1942- (2)
Sjövall, J. (1)
Tagesson, C (1)
Egestad, B (1)
Leandersson, P (1)
Lärosäte
Göteborgs universitet (2)
Språk
Engelska (2)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (2)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy