1.
  • Barnden, L, et al. (författare)
  • Validation of fully automatic brain SPET to MR co-registration
  • 2000
  • Ingår i: EUROPEAN JOURNAL OF NUCLEAR MEDICINE. - 0340-6997. ; 27:2, s. 147-154
  • Tidskriftsartikel (refereegranskat)abstract
    • Fully automatic co-registration of functional to anatomical brain images using information intrinsic to the scans has been validated in a clinical setting for positron emission tomography (PET), but not for single-photon emission tomography (SPET). In thi
  •  
2.
  • Benjegård, S A, et al. (författare)
  • Intraoperative tumour detection using 111In-DTPA-D-Phe1-octreotide and a scintillation detector.
  • 2001
  • Ingår i: European journal of nuclear medicine. - : Springer Science and Business Media LLC. - 0340-6997 .- 1619-7070 .- 1619-7089. ; 28:10, s. 1456-62
  • Tidskriftsartikel (refereegranskat)abstract
    • Intraoperative tumour detection has been used in many applications. The examined tumour forms have varied and different detector systems and radiopharmaceuticals have also been used. The aim of this study was to evaluate and compare the ability of an NaI(T1) scintillation detector to detect primary tumours and metastases in patients with different endocrine tumour types (e.g. carcinoid tumours, endocrine pancreatic tumours and thyroid tumours) and in patients with breast carcinoma or benign thyroid lesions, on the basis of their somatostatin receptor expression after i.v. injection of 111In-DTPA-D-Phe1-octreotide. Thirty patients were injected with 111In-DTPA-D-Phe1-octreotide intravenously. Scintigraphic images were taken 1 day after injection of the radiopharmaceutical, and surgery was performed 1-7 days post injection. An NaI(T1) scintillation detector was used for intraoperative tumour detection. Tissue samples were collected during surgery for determination of 111In activity concentration and histopathological examination. The scintigraphic images were positive in 29 out of 30 patients. Intraoperative tumour detection was successful in 43 of 66 collected biopsies: 10 out of 11 for carcinoid tumours, 7 out of 10 for medullary thyroid carcinoma (MTC) and 14 out of 22 for breast cancer. On the basis of our findings we conclude that intraoperative tumour detection with 111In-DTPA-D-Phe1-octreotide using this NaI(T1) detector can be successful especially for carcinoid tumours and endocrine pancreatic tumours, due to the relatively high activity concentrations in these tumour types, but is less successful in other forms of thyroid cancer, including MTC, and breast cancer. For successful intraoperative detection, the detector characteristics are also very important, and further improvement of the detector systems is required to increase the sensitivity and specificity.
  •  
3.
  •  
4.
  •  
5.
  • Dewaraja, Yuni K., et al. (författare)
  • Monte Carlo evaluation of object shape effects in iodine-131 SPET tumor activity quantification
  • 2001
  • Ingår i: European Journal Of Nuclear Medicine. - : Springer Science and Business Media LLC. - 1432-105X .- 0340-6997 .- 1619-7089. ; 28:7, s. 900-906
  • Tidskriftsartikel (refereegranskat)abstract
    • In our clinical iodine-131 single-photon emission tomography (SPET) quantification for radioimmunotherapy, calibration and partial volume correction are based on measurements with phantoms containing spheres to simulate patient tumors even though real tumors are frequently nonspherical. In this study, Monte Carlo simulation was used to evaluate how object shape influences "spill-out" and "spill-in", which are major sources of quantification error associated with the poor spatial resolution of 131I SPET. Objects that varied in shape (spheres, cylinders, and an irregular structure) but were identical in activity and volume were simulated. Iterative reconstruction employed both attenuation and triple-energy-window scatter compensation. VOIs were defined in the reconstructed images both using physical boundaries and using expanded boundaries to allow for the limited resolution. When physical boundaries were used, both spill-out and spill-in were more significant for nonspherical structures than for spherical structures. Over the range of object volumes (50-200 ml) and at all background levels, VOI counts in cylinders were lower than VOI counts in spheres. This underestimation increased with decrease in object size (for the cold background -18% at 200 ml and -39% at 50 ml). It also decreased with increase in background activity because spill-in partially compensated for spill-out. It was shown that with a VOI larger than physical size, the results are independent of object shape and size only in the case of cold background. Activity quantification was carried out using a procedure similar to that used in our clinic. Quantification of nonspherical objects was improved by simple sphere-based partial volume correction, but the error was still large in some cases (for example, -39% for a 50-ml cylinder in a cold background and -35% for a 200-ml irregular structure defined on the basis of a typical tumor outlined on an X-ray computed tomography scan of a patient with non-Hodgkin's lymphoma). Partial volume correction by patient-specific Monte Carlo simulation may provide better quantification accuracy.
  •  
6.
  •  
7.
  •  
8.
  •  
9.
  •  
10.
  •  