SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0720 048X OR L773:1872 7727 srt2:(2020-2024)"

Sökning: L773:0720 048X OR L773:1872 7727 > (2020-2024)

  • Resultat 1-10 av 25
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Björkman, Ann-Sofi, et al. (författare)
  • Spectral photon-counting CT: Image quality evaluation using a metal-containing bovine bone specimen
  • 2023
  • Ingår i: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 168
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To find the optimal imaging parameters for a photon-counting detector CT (PCD-CT) and to compare it to an energy-integrating detector CT (EID-CT) in terms of image quality and metal artefact severity using a metal-containing bovine knee specimen. Methods: A bovine knee with a stainless-steel plate and screws was imaged in a whole-body research PCD-CT at 120 kV and 140 kV and in an EID dual-source CT (DSCT) at Sn150 kV and 80/Sn150 kV. PCD-CT virtual monoenergetic 72 and 150 keV images and EID-CT images processed with and without metal artefact reduction algorithms (iMAR) were compared. Four radiologists rated the visualisation of bony structures and metal artefact severity. The Friedman test and Wilcoxon signed-rank test with Bonferronis correction were used. P-values of <= 0.0001 were considered statistically significant. Distributions of HU values of regions of interest (ROIs) in artefact-affected areas were analysed.Results: PCD-CT 140 kV 150 keV images received the highest scores and were significantly better than EID-CT Sn150 kV images. PCD-CT 72 keV images were rated significantly lower than all the others. HU-value variation was larger in the 120 kV and the 72 keV images. The ROI analysis revealed no large difference between scanners regarding artefact severity.Conclusion: PCD-CT 140 kV 150 keV images of a metal-containing bovine knee specimen provided the best image quality. They were superior to, or as good as, the best EID-CT images; even without the presumed advantage of tin filter and metal artefact reduction algorithms. PCD-CT is a promising method for reducing metal artefacts.
  •  
2.
  • Boita, Joana, et al. (författare)
  • Validation of a candidate instrument to assess image quality in digital mammography using ROC analysis
  • 2021
  • Ingår i: European Journal of Radiology. - : Elsevier BV. - 1872-7727 .- 0720-048X. ; 139
  • Tidskriftsartikel (refereegranskat)abstract
    • PurposeTo validate a candidate instrument, to be used by different professionals to assess image quality in digital mammography (DM), against detection performance results.MethodsA receiver operating characteristics (ROC) study was conducted to assess the detection performance in DM images with four different image quality levels due to different quality issues. Fourteen expert breast radiologists from five countries assessed a set of 80 DM cases, containing 60 lesions (40 cancers, 20 benign findings) and 20 normal cases. A visual grading analysis (VGA) study using a previously-described candidate instrument was conducted to evaluate a subset of 25 of the images used in the ROC study. Eight radiologists that had participated in the ROC study, and seven expert breast-imaging physicists, evaluated this subset. The VGA score (VGAS) and the ROC and visual grading characteristics (VGC) areas under the curve (AUCROC and AUCVGC) were compared.ResultsNo large differences in image quality among the four levels were detected by either ROC or VGA studies. However, the ranking of the four levels was consistent: level 1 (partial AUCROC: 0.070, VGAS: 6.77) performed better than levels 2 (0.066, 6.15), 3 (0.061, 5.82), and 4 (0.062, 5.37). Similarity between radiologists’ and physicists’ assessments was found (average VGAS difference of 10 %).ConclusionsThe results from the candidate instrument were found to correlate with those from ROC analysis, when used by either observer group. Therefore, it may be used by different professionals, such as radiologists, radiographers, and physicists, to assess clinically-relevant image quality variations in DM.
  •  
3.
  • Booij, Ronald, et al. (författare)
  • Assessment of visibility of bone structures in the wrist using normal and half of the radiation dose with photon-counting detector CT
  • 2023
  • Ingår i: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 159
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To quantitatively and qualitatively assess the visibility of bone structures in the wrist on photon-counting detector computed tomography (PCD-CT) images compared to state-of-the-art energy-integrating de-tector CT (EID-CT).Method: Four human cadaveric wrist specimens were scanned with EID-CT and PCD-CT at identical CTDIvolof 12.2 mGy and with 6.1 mGy (half dose PCD-CT). Axial images were reconstructed using the thinnest possible slice thickness, i.e. 0.4 mm on EID-CT and 0.2 mm on PCD-CT, with the largest image matrix size possible using reconstruction kernels optimized for bone (EID-CT: Ur68, PCD-CT: Br92). Quantitative evaluation was performed to determine contrast-noise ratio (CNR) of bone/ fat, cortical and trabecular sharpness. An observer study using visual grading characteristics (VGC) analysis was performed by six observers to assess the visibility of nutrient canals, trabecular architecture, cortical bone and the general image quality.Results: At equal dose, images obtained with PCD-CT had 39 +/- 6 % lower CNR (p = 0.001), 71 +/- 57 % higher trabecular sharpness in the radius (p = 0.02) and 42 +/- 8 % (p < 0.05) sharper cortical edges than those obtained with EID-CT. This was confirmed by VGC analysis showing a superior visibility of nutrient canals, trabeculae and cortical bone area under the curve (AUC) > 0.89) for PCD-CT, even at half dose.Conclusions: Despite a lower CNR and increased noise, the trabecular and cortical sharpness were twofold higher with PCD-CT. Visual grading analysis demonstrated superior visibility of cortical bone, trabeculae, nutrient canals and an overall improved image quality with PCD-CT over EID-CT. At half dose, PCD-CT also yielded superior image quality, both in quantitative measures and as evaluated by radiologists.
  •  
4.
  •  
5.
  • Fredäng Kämmerling, Nina, et al. (författare)
  • A comparative study of image quality and diagnostic confidence in diagnosis and follow-up of scaphoid fractures using photon-counting detector CT and energy-integrating detector CT
  • 2024
  • Ingår i: European Journal of Radiology. - : ELSEVIER IRELAND LTD. - 0720-048X .- 1872-7727. ; 173
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: Scaphoid fractures in patients and assessment of healing using PCD-CT have, as far as we know, not yet been studied. Therefore, the aim was to compare photon counting detector CT (PCD-CT) with energy integrating detector CT (EID-CT) in terms of fracture visibility and evaluation of fracture healing. Method: Eight patients with scaphoid fracture were examined with EID-CT and PCD-CT within the first week posttrauma, and with additional scans at 4, 6 and 8 weeks. Our clinical protocol for wrist examination with EID-CT was used (CTDIvol 3.1 +/- 0.1 mGy, UHR kernel Ur77). For PCD-CT matched radiation dose, reconstruction kernel Br89. Quantitative analyses of noise, CNR, trabecular and cortical sharpness, and bone volume fraction were conducted. Five radiologists evaluated the images for fracture visibility, fracture gap consolidation and image quality, and rated their confidence in the diagnosis. Results: The trabecular and cortical sharpness were superior in images obtained with PCD-CT compared with EIDCT. A successive reduction in trabecular bone volume fraction during the immobilized periods was found with both systems. Despite higher noise and lower CNR with PCD-CT, radiologists rated the image quality of PCD-CT as superior. The visibility of the fracture line within 1 -week post -trauma was rated higher with PCD-CT as was diagnostic confidence, but the subsequent assessments of fracture gap consolidation during healing process and the confidence in diagnosis were found equivalent between both systems. Conclusion: PCD-CT offers superior visibility of bone microstructure compared with EID-CT. The evaluation of fracture healing and confidence in diagnosis were rated equally with both systems, but the radiologists found primary fracture visibility and overall image quality superior with PCD-CT.
  •  
6.
  •  
7.
  • Kataria, Bharti, 1955-, et al. (författare)
  • Assessment of image quality in abdominal computed tomography : Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction
  • 2020
  • Ingår i: European Journal of Radiology. - : Elsevier Ireland Ltd. - 0720-048X .- 1872-7727. ; 122
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: To determine the effect of tube load, model-based iterative reconstruction (MBIR) strength and slice thickness in abdominal CT using visual comparison of multi-planar reconstruction images. Method: Five image criteria were assessed independently by four radiologists on two data sets at 42- and 98-mAs tube loads for 25 patients examined on a 192-slice dual-source CT scanner. Effect of tube load, MBIR strength, slice thickness and potential dose reduction was estimated with Visual Grading Regression (VGR). Objective image quality was determined by measuring noise (SD), contrast-to-noise (CNR) ratio and noise-power spectra (NPS). Results: Comparing 42- and 98-mAs tube loads, improved image quality was observed as a strong effect of log tube load regardless of MBIR strength (p < 0.001). Comparing strength 5 to 3, better image quality was obtained for two criteria (p < 0.01), but inferior for liver parenchyma and overall image quality. Image quality was significantly better for slice thicknesses of 2mm and 3mm compared to 1mm, with potential dose reductions between 24%-41%. As expected, with decrease in slice thickness and algorithm strength, the noise power and SD (HU-values) increased, while the CNR decreased. Conclusion: Increasing slice thickness from 1 mm to 2 mm or 3 mm allows for a possible dose reduction. MBIR strength 5 shows improved image quality for three out of five criteria for 1 mm slice thickness. Increasing MBIR strength from 3 to 5 has diverse effects on image quality. Our findings do not support a general recommendation to replace strength 3 by strength 5 in clinical abdominal CT protocols. However, strength 5 may be used in task-based protocols.
  •  
8.
  • Kvist, Ola, et al. (författare)
  • DTI assessment of the maturing growth plate of the knee in adolescents and young adults
  • 2023
  • Ingår i: European Journal of Radiology. - : Elsevier. - 0720-048X .- 1872-7727. ; 162
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To assess the growth plates of the knee in a healthy population of young adults and adolescents using DTI, and to correlate the findings with chronological age and skeletal maturation.METHODS: A prospective, cross-sectional study to assess the tibial and femoral growth plates with DTI in 155 healthy volunteers aged between 14.0 and 21 years old. Echo-planar DTI with 15 directions and b value of 0 and 600 s/mm2 was performed on a 3 T whole-body scanner.RESULTS: A relationship was observed between chronological age and most DTI metrics (fractional anisotropy, mean diffusivity, and radial diffusivity), tract length and volume. (No significant relationship could be seen for axonal diffusivity and tract length.) Subdivision according to skeletal maturation showed the greatest tract lengths and volumes seen in stage 4b and not 4a. The intra-observer agreement was significant (P = 0.01) for all the measured variables, but agreement varied (femur 0.53 - 0.98; tibia 0.58 - 0.98). Spearman's correlation showed a significant correlation for age (P = 0.05; P = 0.01) as well as for the fractional anisotropy value within all variables in both femur and tibia. Tract number and volume had a similar correlation with most variables, especially the DTI metrics, and would seem to be interchangeable.CONCLUSION: The current study indicates that DTI metrics could be a tool to assess the skeletal maturation process of the growth plate and its activity. Tractography seems promising to assess the activity of the growth plate in a younger population but must be used with caution in the more mature growth plate.
  •  
9.
  • Kämmerling, Nina, et al. (författare)
  • Assessment of image quality in photon-counting detector computed tomography of the wrist - An ex vivo study
  • 2022
  • Ingår i: European Journal of Radiology. - : Elsevier Ireland Ltd. - 0720-048X .- 1872-7727. ; 154
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The aim of this study was to evaluate the effect of reconstruction parameters on image quality in wrist imaging using photon-counting detector CT (PCD-CT) and to compare the results with images from an energyintegrating detector CT (EID-CT). Methods: Twelve cadaveric wrist specimens were examined using a prototype PCD-CT and a clinical EID-CT using similar radiation dose. Reconstruction parameters were matched between scanners. Also, sharper reconstruction kernels, a larger matrix size, and smaller slice thicknesses were evaluated for PCD-CT. Image noise, contrast-tonoise ratio (CNR) and image sharpness in trabecular structures were quantitatively measured. Image quality with respect to the visibility of cortical and trabecular bone structures was assessed by six radiologists using visual grading methods.Results: Images obtained with PCD-CT had lower noise (42.6 +/- 3.9 HU vs 75.1 +/- 6.3 HU), higher CNR (38.9 +/- 4.5 vs 19.0 +/- 2.4) and higher trabecular sharpness (63.5 +/- 6.0 vs 53.7 +/- 8.5) than those obtained with EID-CT using similar scan and reconstruction parameters (p < 0.001). The image sharpness in trabecular structures was further improved by using sharper kernels, despite higher noise levels. Radiologists had a strong preference for PCD-CT images both in terms of spatial resolution and suitability for bone imaging. Visual grading analysis showed an improved visibility of cortical bone, trabeculae and nutritive canals (p < 0.005).Conclusion: PCD-CT offers improved image quality regarding bone structures in the wrist relative to EID-CT systems, particularly when sharper reconstruction kernels, smaller slice thickness and a larger image matrix size are used.
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 25
Typ av publikation
tidskriftsartikel (24)
forskningsöversikt (1)
Typ av innehåll
refereegranskat (23)
övrigt vetenskapligt/konstnärligt (2)
Författare/redaktör
Persson, Anders (4)
Zackrisson, Sophia (3)
Tesselaar, Erik (3)
Wang, Q. (2)
Grigoriadis, A (2)
Bergquist, A (2)
visa fler...
Kartalis, N (2)
Bolejko, Anetta (2)
Tingberg, Anders (2)
Bosmans, Hilde (2)
Sechopoulos, Ioannis (2)
Farnebo, Simon (2)
Van Ongeval, Chantal (2)
Broeders, Mireille (2)
Hu, X. (1)
Diaz, Sandra (1)
Eriksson, Anders (1)
Sanmartin Berglund, ... (1)
Johansson, K (1)
Chen, D (1)
Wang, A (1)
Andersson, M (1)
Nilsson, H (1)
Arnelo, U (1)
Wallin, Göran, 1952- (1)
Smedby, Örjan, Profe ... (1)
Nilsson, Ola, 1970- (1)
Sakamoto, A (1)
Maier, Stephan E, 19 ... (1)
Koskinen, Seppo (1)
Gimm, Oliver (1)
Lenzen, H (1)
Manns, MP (1)
Brismar, TB (1)
Lynöe, Niels (1)
Sandborg, Michael, 1 ... (1)
Woisetschläger, Misc ... (1)
Ullén, Susann (1)
Gauffin, Håkan (1)
Sartor, Hanna (1)
Flodmark, Carl-Erik (1)
Wu, XY (1)
Förnvik, Hannie (1)
Bai, G (1)
Förnvik, Daniel (1)
Hofvind, Solveig (1)
Staal, P (1)
Moreno, Rodrigo, 197 ... (1)
Kadesjo, N (1)
Zhao, D (1)
visa färre...
Lärosäte
Karolinska Institutet (10)
Linköpings universitet (6)
Lunds universitet (6)
Umeå universitet (4)
Kungliga Tekniska Högskolan (2)
Örebro universitet (2)
visa fler...
Göteborgs universitet (1)
Blekinge Tekniska Högskola (1)
visa färre...
Språk
Engelska (25)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (15)
Teknik (6)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy