SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0730 725X OR L773:1873 5894 srt2:(2010-2014)"

Sökning: L773:0730 725X OR L773:1873 5894 > (2010-2014)

  • Resultat 1-10 av 23
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  • Dyverfeldt, Petter, et al. (författare)
  • Pulse wave velocity with 4D flow MRI: Systematic differences and age-related regional vascular stiffness
  • 2014
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier. - 0730-725X .- 1873-5894. ; 32:10, s. 1266-1271
  • Tidskriftsartikel (refereegranskat)abstract
    • Purpose: The objective of this study was to compare multiple methods for estimation of PWV from 4D flow MRI velocity data and to investigate if 4D flow MRI-based PWV estimation with piecewise linear regression modeling of travel-distance vs. travel time is sufficient to discern age-related regional differences in PWV. Methods: 4D flow MRI velocity data were acquired in 8 young and Solder (age: 23 +/- 2 vs. 58 +/- 2 years old) normal volunteers. Travel-time and travel-distance were measured throughout the aorta and piecewise linear regression was used to measure global PWV in the descending aorta and regional PWV in three equally sized segments between the top of the aortic arch and the renal arteries. Six different methods for extracting travel-time were compared. Results: Methods for estimation of travel-time that use information about the whole flow waveform systematically overestimate PWV when compared to methods restricted to the upslope-portion of the waveforms (p less than 0.05). In terms of regional PWV, a significant interaction was found between age and location (p less than 0.05). The age-related differences in regional PWV were greater in the proximal compared to distal descending aorta. Conclusion: Care must be taken as different classes of methods for the estimation of travel-time produce different results. 4D flow MRI-based PWV estimation with piecewise linear regression modeling of travel-distance vs. travel time can discern age-related differences in regional PWV well in line with previously reported data.
  •  
3.
  • Filippov, Andrei, et al. (författare)
  • Dynamic properties of water in silicalite-1 powder
  • 2012
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X .- 1873-5894. ; 30:7, s. 1022-1031
  • Tidskriftsartikel (refereegranskat)abstract
    • Self-diffusion of D2O in partially filled silicalite-1 crystals was studied at 25 degrees C by H-2 nuclear magnetic resonance (NMR) with bipolar field gradient pulses and longitudinal Eddy-current-delay. For the first time, reliable experimental diffusion data for this system were obtained. Analysis of NMR diffusion decays revealed the presence of a continuous distribution of apparent self-diffusion coefficients (SDCs) of water, ranging from 10(-7) to similar to 10(-10) m(2)/s, which include values much higher and lower than that of bulk water (similar to 10(-9) m(2)/s) in liquid phase. The observed distribution of SDC changes with variation of the diffusion time in the range of 10-200 ms. A two-site Karger exchange model was successfully fitted to the data. Finally, the water distribution and exchange in silicalite-1 pores were described by taking into account (a) a gas-like phase in the zeolite pores, a gas-like phase in mesopores and an intercrystalline gas-like phase and (b) intercrystalline liquid droplets with intermediate exchange rate with the other phases. The other phases experience fast exchange on the NMR diffusion time scale. Diffusion coefficients and mean residence times of water in some of these states were estimated.
  •  
4.
  • Filippov, Andrei, et al. (författare)
  • Lateral diffusion in equimolar mixtures of natural sphingomyelins with dioleoylphosphatidylcholine
  • 2012
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier. - 0730-725X .- 1873-5894. ; 30:3, s. 413-421
  • Tidskriftsartikel (refereegranskat)abstract
    • Cellular membranes of mammals are composed of a complex assembly of diverse phospholipids. Sphingomyelin (SM) and phosphatidylcholine (PC) are important lipids of eukaryotic cellular membranes and neuronal tissues, and presumably participate in the formation of membrane domains, known as "rafts," through intermolecular interaction and lateral microphase decomposition. In these two-dimensional membrane systems, lateral diffusion of lipids is an essential dynamic factor, which might even be indicative of lipid phase separation process. Here, we used pulsed field gradient nuclear magnetic resonance to study lateral diffusion of lipid components in macroscopically oriented bilayers composed of equimolar mixtures of natural SMs of egg yolk, bovine brain, bovine milk and dipalmitoylphosphatidylcholine (DPPC) with dioleoylphosphatidylcholine (DOPC). In addition, differential scanning calorimetry was used as a complementary technique to characterize the phase state of the lipid bilayers. In fully liquid bilayers, the lateral diffusion coefficients in both DOPC/DPPC and DOPC/SM systems exhibit mean values of the pure bilayers. For DOPC/SM bilayer system, this behavior can be explained by a model where most SM molecules form short-lived lateral domains with preferential SM-SM interactions occurring within them. However, for bilayers in the presence of their low-temperature gel phase, lateral diffusion becomes complicated and cannot simply be understood solely by a simple change in the liquid phase decomposition.
  •  
5.
  • Knutsson, Linda, et al. (författare)
  • Absolute quantification of cerebral blood flow: correlation between dynamic susceptibility contrast MRI and model-free arterial spin labeling.
  • 2010
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 1873-5894 .- 0730-725X. ; 28:1, s. 1-7
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To compare absolute cerebral blood flow (CBF) estimates obtained by model-free arterial spin labeling (ASL) and dynamic susceptibility contrast MRI (DSC-MRI), corrected for partial volume effects (PVEs). METHODS: CBF was measured using DSC-MRI and model-free ASL (quantitative signal targeting with alternating radiofrequency labeling of arterial regions) at 3 T in 15 subjects with brain tumor, and the two modalities were compared with regard to CBF estimates in normal gray matter (GM) and DSC-to-ASL CBF ratios in selected tumor regions. The DSC-MRI CBF maps were calculated using a global arterial input function (AIF) from the sylvian-fissure region, but, in order to minimize PVEs, the AIF time integral was rescaled by a venous output function time integral obtained from the sagittal sinus. RESULTS: In GM, the average DSC-MRI CBF estimate was 150+/-45 ml/(min 100 g) (mean+/-SD) while the corresponding ASL CBF was 44+/-10 ml/(min 100 g). The linear correlation between GM CBF estimates obtained by DSC-MRI and ASL was r=.89, and observed DSC-to-ASL CBF ratios differed by less than 3% between GM and tumor regions. CONCLUSIONS: A satisfactory positive linear correlation between the CBF estimates obtained by model-free ASL and DSC-MRI was observed, and DSC-to-ASL CBF ratios showed no obvious tissue dependence.
  •  
6.
  • Knutsson, Linda, et al. (författare)
  • Effects of blood ΔR(2)* non-linearity on absolute perfusion quantification using DSC-MRI: Comparison with Xe-133 SPECT.
  • 2013
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 1873-5894 .- 0730-725X. ; 31:5, s. 651-655
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To evaluate whether a non-linear blood ΔR(2)*-versus-concentration relationship improves quantitative cerebral blood flow (CBF) estimates obtained by dynamic susceptibility contrast (DSC) MRI in a comparison with Xe-133 SPECT CBF in healthy volunteers. MATERIAL AND METHODS: Linear as well as non-linear relationships between ΔR(2)* and contrast agent concentration in blood were applied to the arterial input function (AIF) and the venous output function (VOF) from DSC-MRI. To reduce partial volume effects in the AIF, the arterial time integral was rescaled using a corrected VOF scheme. RESULTS: Under the assumption of proportionality between the two modalities, the relationship CBF(MRI)=0.58CBF(SPECT) (r=0.64) was observed using the linear relationship and CBF(MRI)=0.51CBF(SPECT) (r=0.71) using the non-linear relationship. DISCUSSION: A smaller ratio of the VOF time integral to the AIF time integral and a somewhat better correlation between global DSC-MRI and Xe-133 SPECT CBF estimates were observed using the non-linear relationship. The results did not, however, confirm the superiority of one model over the other, potentially because realistic AIF signal data may well originate from a combination of blood and surrounding tissue.
  •  
7.
  • Lavdas, Eleftherios, et al. (författare)
  • Comparison of BLADE and conventional T2-TSE sequences for the sagittal visualization of the cervical spinal cord in multiple sclerosis patients - A case report
  • 2013
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X .- 1873-5894. ; 31:10, s. 1766-1770
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study is to report the significant differences found in the identification of lesions in cervical spinal cord of two patients with multiple sclerosis when using the BLADE T2-TSE and BLADE T2-TIRM sequences as opposed to the conventional T2-TSE and T2-TIRM sequences for sagittal acquisition at 1.5 T. In both patients, one more lesion was identified with the BLADE sequences than with the conventional ones. Consequently, we suggest the use of BLADE T2-TSE and BLADE T2-TIRM sequences in place of conventional ones for sagittal examination of the cervical spinal cord of multiple sclerosis patients. The advantages of TIRM to reveal the pathology of the cervical spinal cord and the advantage of BLADE sequences to improve image quality should be combined in a sequence that could be ideal for cervical spinal cord examinations.
  •  
8.
  • Lavdas, Eleftherios, et al. (författare)
  • Comparison of PD BLADE with fat saturation (FS), PD FS and T2 3D DESS with water excitation (WE) in detecting articular knee cartilage defects
  • 2013
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X .- 1873-5894. ; 31:8, s. 1255-1262
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study, is to compare the sequences: 1) proton density (PD) BLADE (BLADE is a PROPELLER-equivalent implementation of the Siemens Medical System) with fat saturation (FS) coronal (COR), 2) PD FS COR, 3) multi-planar reconstruction (MPR) with 3 mm slice thickness and 4) multi-planar reconstruction (MPR) with 1.5 mm slice thickness, both from the T2 3D-double-echo steady state (DESS) with water excitation (WE) sagittal (SAG), regarding their abilities to identify changes in the femorotibial condyle cartilage in knee MRI examinations. Thirty three consecutive patients with osteoarthritis (18 females, 15 males; mean age 56 years, range 37-71 years), who had been routinely scanned for knee examination using the previously mentioned image acquisition techniques, participated in the study. A quantitative analysis was performed based on the relative contrast (ReCON) measurements, which were taken both on normal tissues as well as on pathologies. Additionally, a qualitative analysis was performed by two radiologists. Motion and pulsatile flow artifacts were evaluated. The PD BLADE FS COR sequence produced images of higher contrast between Menisci and Cartilage, Fluid and Cartilage, Pathologies and Cartilage as well as of the Conspicuousness Superficial Cartilage and it was found to be superior to the other sequences (p < 0.001). The sequences T2 3D DESS 1.5 mm and T2 3D DESS 3 mm were significantly superior to the PD BLADE FS COR and the PD FS COR sequences in the visualization of Bone and Cartilage and the Conspicuousness Deep Surface Cartilage. This pattern of results is also confirmed by the quantitative analysis. PD FS BLADE sequences are ideal for the depiction of the cartilage pathologies compared to the conventional PD FS and 12 3D DESS sequences.
  •  
9.
  •  
10.
  • Lavdas, Eleftherios, et al. (författare)
  • Elimination of motion and pulsation artifacts using BLADE sequences in knee MR imaging
  • 2012
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X .- 1873-5894. ; 30:8, s. 1099-1110
  • Tidskriftsartikel (refereegranskat)abstract
    • The purpose of this study is to evaluate the ability of proton density (PD)-BLADE sequences in reducing or even eliminating motion and pulsatile flow artifacts in knee magnetic resonance imaging examinations. Eighty consecutive patients, who had been routinely scanned for knee examination, participated in the study. The following pairs of sequences with and without BLADE were compared: (a) PD turbo spin echo (TSE) sagittal (SAG) fat saturation (FS) in 35 patients, (b) PD TSE coronal (CUR) FS in 19 patients, (c) T2 TSE axial in 13 patients and (d) PD TSE SAG in 13 patients. Both qualitative and quantitative analyses were performed based on the signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and relative contrast (ReCon) measures of normal anatomic structures. The qualitative analysis was performed by experienced radiologists. Also, the presence of image motion and pulsation artifacts was evaluated. Based on the results of the SNR, CRN and ReCon for the different sequences and anatomical structures, the BLADE sequences were significantly superior in 19 cases, whereas the corresponding conventional sequences were significantly superior in only 6 cases. BLADE sequences eliminated motion artifacts in all the cases. However, motion artifacts were shown in (a) six PD TSE SAG FS, (b) three PD TSE CUR FS, (c) three PD TSE SAG and (d) two T2 TSE axial conventional sequences. In our results, it was found that, in PD FS sequences (sagittal and coronal), the differences between the BLADE and conventional sequences regarding the elimination of motion and pulsatile flow artifacts were statistically significant. In all the comparisons, the PD FS BLADE sequences (coronal and sagittal) were significantly superior to the corresponding conventional sequences regarding the classification of their image quality. In conclusion, this technique appears to be capable to potentially eliminate motion and pulsatile flow artifacts in MR images.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 23
Typ av publikation
tidskriftsartikel (23)
Typ av innehåll
refereegranskat (23)
Författare/redaktör
Mavroidis, Panayioti ... (5)
Wirestam, Ronnie (4)
Ståhlberg, Freddy (4)
Knutsson, Linda (3)
Ahlström, Håkan (2)
Nilsson, Markus (2)
visa fler...
van Westen, Danielle (2)
Ebbers, Tino (2)
Filippov, Andrei (2)
Dyverfeldt, Petter (2)
Johansson, Lars (1)
Dvinskikh, Sergey V. (1)
Furo, Istvan (1)
Holtås, Stig (1)
Helms, Gunther (1)
Alhadad, Alaa (1)
Mavroidis, P (1)
Skare, S (1)
Knutsson, Hans (1)
Hedlund, Jonas (1)
Sundin, Anders (1)
Lind, Emelie (1)
Länne, Toste (1)
Johansson, Edvin (1)
Leander, Peter (1)
Gröbner, Gerhard (1)
Sterner, Gunnar (1)
Svenningsson, Per (1)
Bammer, R (1)
Liu, Xiang (1)
Åkesson, Michael (1)
Lehti, Leena (1)
Åkeson, Per (1)
Wasselius, Johan (1)
Allers, Mats (1)
Lunderquist, Anders (1)
Månsson, Sven (1)
Ekholm, Sven (1)
Lilja, A (1)
Grahn, Mattias (1)
Rubertsson, Sten (1)
Antzutkin, Oleg (1)
Peterson, Pernilla (1)
Lätt, Jimmy (1)
Sigfridsson, Andreas (1)
Markenroth Bloch, Ka ... (1)
Liu, Jing (1)
Skorpil, Mikael (1)
Olsrud, Johan (1)
Covaciu, Lucian (1)
visa färre...
Lärosäte
Lunds universitet (8)
Karolinska Institutet (8)
Stockholms universitet (5)
Uppsala universitet (3)
Linköpings universitet (3)
Luleå tekniska universitet (2)
visa fler...
Göteborgs universitet (1)
Umeå universitet (1)
Kungliga Tekniska Högskolan (1)
visa färre...
Språk
Engelska (23)
Forskningsämne (UKÄ/SCB)
Medicin och hälsovetenskap (16)
Teknik (5)
Naturvetenskap (3)

År

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy