SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0895 7959 OR L773:1477 2299 srt2:(1990-1994)"

Sökning: L773:0895 7959 OR L773:1477 2299 > (1990-1994)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Andersson, Britt M., et al. (författare)
  • Electrical resistivity and critical temperature of Bi-based high-Tc superconductors to 1 GPa
  • 1990
  • Ingår i: High Pressure Research, volumes 3 to 5. - London : Gordon and Breach. - 2881247466 ; 3:1-6, s. 120-122
  • Konferensbidrag (refereegranskat)abstract
    • We have measured the electrical resistance R of a sintered, two-phase, high-TC superconductor with the nominal composition BiSrCaCu2Ox, as a function of T and p. We find d(lnR)/dp ≃ -0.06 GPa-1 at 295 K, while dTC/dp is 2.5 K/GPa for the phase with Tc ≃ 76 and 2 K/GPa for that with TC ≃ 106 K.
  •  
2.
  • Andersson, Britt M., et al. (författare)
  • High-pressure properties of high-Tc superconductor samples produced by hot isostatic pressing
  • 1990
  • Ingår i: High Pressure Research, volumes 3 to 5. - London : Gordon and Breach. - 2881247466 ; 3:1-6, s. 123-125
  • Konferensbidrag (refereegranskat)abstract
    • The electrical resistance of dense YBa2Cu3Ox and YBa2Cu4Oy produced by hot isostatic pressing has been measured vs. T and p. At 295 K we find d (ln R)/dp ≃ -0.12 and -0.09 GPa-1, respectively, with no systematic dependence on initial density. For 1-2-4, dTC/dp ≃ 5.1 K/GPa, which is ten times that of 1-2-3.
  •  
3.
  • Andersson, Ove, et al. (författare)
  • A low-temperature high-pressure apparatus with a temperature control system
  • 1992
  • Ingår i: High Pressure Research. - : Informa UK Limited. - 0895-7959 .- 1477-2299. ; 10:4, s. 599-606
  • Tidskriftsartikel (refereegranskat)abstract
    • A low-temperature high-pressure apparatus was designed using commercial cryogenic equipment. Pressures up to 1 GPa and temperatures down to 40 K can be obtained in a volume of up to 30 cm3. The apparatus is of the piston-cylinder type with a piston diameter of 45 mm, and the pressure can be varied at all temperatures, An adaptive temperature control system keeps the temperature inside the pressure cylinder constant to within ±0.1 K.
  •  
4.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy