SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0925 4439
 

Sökning: L773:0925 4439 > (2000-2004) > Low-frequency low-f...

Low-frequency low-field magnetic susceptibility of ferritin and hemosiderin

Allen, P. D. (författare)
St Pierre, T. G. (författare)
Chua-anusorn, W. (författare)
visa fler...
Ström, Valter (författare)
KTH,Materialvetenskap
Rao, K. V. (författare)
visa färre...
 (creator_code:org_t)
2000
2000
Engelska.
Ingår i: Biochimica et Biophysica Acta - Molecular Basis of Disease. - 0925-4439 .- 1879-260X. ; 1500:2, s. 186-196
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Low-frequency low-field magnetic susceptibility measurements were made on four samples of mammalian tissue iron oxide deposits. The samples comprised: (1) horse spleen ferritin; (') dugong liver hemosiderin; (3) thalassemic human spleen ferritin; and (4) crude thalassemic human spleen hemosiderin. These samples were chosen because Mossbauer spectroscopic measurements on the samples indicated that they exemplified the variation in magnetic and mineral structure found in mammalian tissue iron oxide deposits. The AC-magnetic susceptometry yielded information on the magnetization kinetics of the four samples indicating samples 1, 2, and 3 to be superparamagnetic with values of around 10(11) s(-1) for the preexponential frequency factor in the Neel-Arrhenius equation and values for characteristic magnetic anisotropy energy barriers in the range 250-400 K. Sample 4 was indicated to he paramagnetic at all temperatures above 1.3 K. The AC-magnetic susceptometry data also indicated a larger magnetic anisotropy energy distribution in the dugong liver sample compared with samples 1 and 3 in agreement with previous Mossbauer spectroscopic data on these samples. At temperatures below 200 K, samples 1-3 exhibited Curie-Weiss law behavior, indicating weak particle-particle interactions tending to favor antiparallel alignment of the particle magnetic moments. These interactions were strongest for the dugong liver hemosiderin. possibly reflecting the smaller separation between mineral particles in this sample. This is the first magnetic susceptometry study of hemosiderin iron deposits and demonstrates that the AC-magnetic susceptometry technique is a fast and informative method of studying such tissue iron oxide deposits.

Nyckelord

AC-magnetic susceptibility
ferritin
hemosiderin
superparamagnetism
iron oxide
Mossbauer spectroscopy
iron-oxide deposits
thalassemia hemoglobin-e
mossbauer-spectroscopy
overload diseases
cores
tissues
spleen
limpet

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy