SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0957 4530 srt2:(1995-1999)"

Sökning: L773:0957 4530 > (1995-1999)

  • Resultat 1-6 av 6
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Esposito, M, et al. (författare)
  • Failure patterns of four osseointegrated oral implant systems
  • 1997
  • Ingår i: Journal of materials science. Materials in medicine. - 0957-4530 .- 1573-4838. ; 8:12, s. 843-847
  • Tidskriftsartikel (refereegranskat)abstract
    • The aim of this metanalysis was to investigate possible differences in failure patterns among four different osseointegrated oral implant systems. Only systems with a supposed scientific validation, based on long-term follow-up studies, were selected for this analysis, i.e. the Brånemark system, the Calcitek Integral system, the Interpore IMZ system and the Straumann ITI system. While several prospective reports could be found on the Brånemark system, only a few retrospective investigations concerning the ITI and the IMZ systems were available. No data on the Integral system could be employed. Despite these limitations, a substantial difference in failure patterns among various implant systems was observed. The Brånemark implants showed a higher incidence of early failures, though sharply decreasing over time. On the contrary, IMZ implant characterized by rougher surfaces displayed a lower incidence of early failures, but showed constant or increased failure rates over time. For the ITI implants, for example, a higher prevalence of late failures, attributable to chronic bacterial infection (peri-implantitis), was observed when compared to the Brånemark system. With the exception of the latter implant system, prospective long-term follow-up studies, using similar and well-defined success criteria, are needed for the others to confirm the current preliminary findings.
  •  
2.
  •  
3.
  • Larsson Wexell, Cecilia, 1965, et al. (författare)
  • Bone response to surface modified titanium implants - studies on the tissue response after 1 year to machined and electropolished implants with different oxide thicknesses.
  • 1997
  • Ingår i: Journal of materials science. Materials in medicine. - 0957-4530. ; 8:12, s. 721-9
  • Tidskriftsartikel (refereegranskat)abstract
    • The bone formation around titanium implants with varied surface properties was investigated after 1 year in rabbits. Machined and electropolished samples with and without thick, anodically formed surface oxides were prepared, surface characterized and inserted in the cortical bone of rabbits. Scanning electron microscopy, scanning Auger electron spectroscopy and atomic force microscopy revealed marked differences in oxide thickness, surface topography and roughness, but no significant differences in surface chemical composition between the different groups of implants. Light microscopic morphology and morphometry showed that all implants were in contact with bone and had a large proportion of bone within the threads. There were no significant differences between the differently prepared implant groups. Our study shows that a high degree of bone contact and bone formation is achieved after 1 year with titanium implants which are modified with respect to oxide thickness and surface topography. There is no indication that a reduction of surface roughness, which in the initial phase decreases the rate of bone formation, had any influence on the amount of bone after 1 year in rabbit cortical bone.
  •  
4.
  •  
5.
  • Liljensten, E, et al. (författare)
  • Studies of the healing of bone grafts, and the incorporation of titanium implants in grafted bone: an experimental animal model.
  • 1998
  • Ingår i: Journal of materials science. Materials in medicine. - : Springer Science and Business Media LLC. - 0957-4530 .- 1573-4838. ; 9:9, s. 535-41
  • Tidskriftsartikel (refereegranskat)abstract
    • An insufficient quality and amount of bone often necessitate the clinical use of implants together with bone transplants. The present study describes an experimental animal model for the study of implants in bone grafts. Circular defects were made bilaterally in the tibia of 36 rabbits. The defects received either autologous cortical bone (control), demineralized bone matrix (DBM), plasma-augmented DBM or were left empty (without bone graft). In all defects a titanium implant was centrally placed and anchored in the opposite cortex. Evaluation with light microscopic morphometry showed that the insertion of a threaded titanium implant centrally in a cortical defect was followed by a spontaneous healing of the defect after 6 mon. After 6 wk, all implants in cortical grafts were well integrated with a significantly higher bone-to-implant contact than in the DBM and plasma-augmented groups. After 6 mon, all experimental groups had a mean bone area within the threads ranging between 69% and 80% and a mean bone-to-implant contact between 31% and 42%. The results from the present study indicate that the model allows comparative studies on the early formation, resorption and remodelling of bone around implants after modification of implant, graft and host properties.
  •  
6.
  • Thomsen, Peter, 1953, et al. (författare)
  • Structure of the interface between rabbit cortical bone and implants of gold, zirconium and titanium.
  • 1997
  • Ingår i: Journal of materials science. Materials in medicine. - 0957-4530. ; 8:11, s. 653-65
  • Tidskriftsartikel (refereegranskat)abstract
    • The role of surface properties (chemical and structural) for the interaction between biomaterials and tissue is not yet understood. In the present study, implants made of titanium, zirconium (transition metals with surface oxides) and gold (metallic surface) were inserted into the rabbit tibia. Light microscopic (LM) morphometry showed that after 1 and 6 mo the gold implants had less amount of bone within the threads and a lower degree of bone-implant contact than the titanium and zirconium implants, which did not differ from each other. These quantitative differences were supported by LM and ultrastructural observations of the interface. The ultrastructural observations in addition demonstrated that the layer of non-collagenous amorphous material located between the implant and the calcified bone was appreciably thicker around zirconium than around titanium implants. The factors potentially responsible for the observed morphological differences in the bone around the different material surfaces are discussed.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-6 av 6

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy