SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:0968 5243 OR L773:1352 8661 srt2:(2000-2004)"

Sökning: L773:0968 5243 OR L773:1352 8661 > (2000-2004)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Bjørnerud, A., et al. (författare)
  • Pre-clinical results with Clariscan (NC100150 Injection) : experience from different disease models
  • 2001
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - 0968-5243 .- 1352-8661. ; 12:2-3, s. 99-103
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)abstract
    • A superparamagnetic nanoparticle (NC100150 Injection) was investigated in two different animal models; renal perfusion in pigs and tumour imaging in mice. In the pig model, qualitative first-pass perfusion maps following a bolus injection of NC100150 Injection enabled good visualisation of hypoperfused regions of the renal cortex following partial ligation of the renal artery. High temporal resolution was found to be essential to accurately capture the first passage of the contrast agent through the kidney due to the very rapid blood flow in normal renal cortex. In the tumour model (LS174T cells implanted in nude mice), NC100150 Injection was found to cause a gradual (over 60 min) signal increase on T1-w images in part of the tumours which was attributed to contrast agent leakage from the vascular space to the extravascular space in areas of increased capillary permeability. This observation is consistent with previous reports on the molecular cut-off size for vascular extraction for this tumour cell line. The specific enhancement of tumour tissue suggest potential utility of NC100150 Injection as an angiogenesis marker.
  •  
2.
  •  
3.
  •  
4.
  • Hemmingsson, Anders, et al. (författare)
  • Contrast agents in acute myocardial infarction
  • 2001
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - 0968-5243 .- 1352-8661. ; 12:2-3, s. 96-98
  • Tidskriftsartikel (refereegranskat)abstract
    • The experimental design in examination of acute myocardial infarctions should be valid in terms of flow, perfusion and re-flow after intervention. The contrast agents concentration in experimental studies can be measured by microdialysis. We have assessed the usefulness of different extracellular and blood pool contrast agents for visualization of the area at risk in coronary artery occlusions. The double contrast technique, where Dy-DTPA-BMA was combined with Gd-DTPA-BMA yielded a superior infarct visualization. Blood pool agents for example NC100/150 injection is also promising in first path myocardial perfusion imaging.
  •  
5.
  •  
6.
  • Weis, Jan, et al. (författare)
  • Spectroscopic imaging of bone marrow composition in vertebral bodies
  • 2001
  • Ingår i: Magnetic Resonance Materials in Physics, Biology and Medicine. - 0968-5243 .- 1352-8661. ; 13:1, s. 15-18
  • Tidskriftsartikel (refereegranskat)abstract
    • The proton spectroscopic imaging technique that uses read gradient during acquisition was used for the measurement of the proton spectra in the lumbar and thoracic part of the spine of a patient with breast cancer without known skeletal metastases. The bone marrow fat/water ratios were evaluated in the same location before and after chemotherapy treatment. The results were corrected for relaxation effects. The fat/water ratios showed a significant increase as a consequence of the bone marrow degradation process due to chemotherapy. The proposed spectroscopic imaging technique offers rapid acquisition of proton spectra from large volumes of the vertebral bodies.
  •  
7.
  • Wirestam, Ronnie, et al. (författare)
  • Absolute cerebral blood flow measured by dynamic susceptibility contrast MRI: a direct comparison with Xe-133 SPECT
  • 2000
  • Ingår i: Magma. - 1352-8661. ; 11:3, s. 96-103
  • Tidskriftsartikel (refereegranskat)abstract
    • Absolute regional cerebral blood flow (CBF) was measured in ten healthy volunteers, using both dynamic susceptibility-contrast (DSC) magnetic resonance imaging (MRI) and Xe-133 SPECT within 4 h. After i.v. injection of Gd-DTPA-BMA (0.3 mmol/kg b.w.), the bolus was monitored with a Simultaneous Dual FLASH pulse sequence (1.5 s/image), providing one slice through brain tissue and a second slice through the carotid artery. Concentration C(t) is proportional to -(1/TE) ln[S(t)/S(0)] was related to CBF as C(t) = CBF [AIF(t) x R(t)], where AIF is the arterial input function and R(t) is the residue function. A singular-value-decomposition-based deconvolution technique was used for retrieval of R(t). Absolute CBF was given by Zierler's area-to-height relation and the central volume principle. For elimination of large vessels (ELV), all MRI-based CBF values exceeding 2.5 times the mean CBF value of the slice were excluded. A correction for partial-volume effects (CPVE) in the artery used for AIF monitoring was based on registration of signal in a phantom with tubes of various diameters (1.5-6.5 mm), providing an individual concentration correction factor applied to AIF data registered in vivo. In the Xe-133 SPECT investigation, 3,000-4,000 MBq of Xe-133 was administered intravenously, and CBF was calculated using the Kanno Lassen algorithm. When ELV and CPVE were applied, DSC-MRI showed average CBF values from the entire slice of 43 +/- 10 ml/(min 100 g) (small-artery AIF) and 48 +/- 17 ml/(min 100 g) (carotid-artery AIF) (mean +/- S.D., n = 10). The corresponding Xe-133-SPECT-based CBF was 33 +/- 6 ml/(min 100 g) (n = 10). The relationships of CBF(MRI) versus CBF(SPECT) showed good linear correlation (r = 0.74-0.83).
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy