1.
  • Akkurt, I, et al. (författare)
  • Photoneutron yields from tungsten in the energy range of the giant dipole resonance
  • 2003
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 48:20, s. 3345-3352
  • Tidskriftsartikel (refereegranskat)abstract
    • Photoneutron production on the nuclei of high-Z components of medical accelerator heads can lead to a significant secondary dose during a course of bremsstrahlung radiotherapy, However, a quantitative evaluation of secondary neutron dose requires improved data on the photoreaction yields. These have been measured as a function of photon energy, neutron energy and neutron angle for W-nat, using tagged photons at the MAX-Lab photonuclear facility in Sweden. This work presents neutron yields for W-nat(gamma, n) and compares these with the predictions of the Monte Carlo code MCNP-GN, developed specifically to simulate photoneutron production at medical accelerators.
  •  
2.
  •  
3.
  •  
4.
  • Arlig, A, et al. (författare)
  • Attenuation correction in quantitative SPECT of cerebral blood flow: a Monte Carlo study
  • 2000
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 45:12, s. 3847-3859
  • Tidskriftsartikel (refereegranskat)abstract
    • Monte Carlo simulation has been used to produce projections from a voxel-based brain phantom, simulating a 99mTc-HMPAO single photon emission computed tomography (SPECT) brain investigation. For comparison, projections free from the effects of attenuation and scattering were also simulated, giving ideal transaxial images after reconstruction. Three methods of attenuation correction were studied: (a) a pre-processing method, (b) a post-processing uniform method and (c) a post-processing non-uniform method using a density map. The accuracy of these methods was estimated by comparison of the reconstructed images with the ideal images using the normalized mean square error, NMSE, and quantitative values of the regional cerebral blood flow, rCBF. A minimum NMSE was achieved for the effective linear attenuation coefficient mu(eff) = 0.07 (0.09) cm(-1) for the uniform(pre) method, the effective mass attenuation coefficient mu(eff)/rho = 0.08 (0.10) cm2 g(-1) for the uniform(post) method and mu(eff)/rho = 0.12 (0.13) cm2 g(-1) for the non-uniform(post) method. Values in parentheses represent the case of dual-window scatter correction. The non-uniform(post) method performed better, as measured by the NMSE, both with and without scatter correction. Furthermore, the non-uniform(post) method gave, on average, more accurate rCBF values. Although the difference in rCBF accuracy was small between the various methods, the same method should be used for patient studies as for the reference material.
  •  
5.
  • Aznar, MC, et al. (författare)
  • Real-time optical-fibre luminescence dosimetry for radiotherapy: physical characteristics and applications in photon beams
  • 2004
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 49:9, s. 1655-1669
  • Tidskriftsartikel (refereegranskat)abstract
    • A new optical-fibre radiation dosimeter system, based on radioluminescence and optically stimulated luminescence from carbon-doped aluminium oxide, was developed and tested in clinical photon beams. This prototype offers several features, such as a small detector (1 x 1 x 2 mm), high sensitivity, real-time read-out and the ability to measure both dose rate and absorbed dose. The measurements describing reproducibility and output dependence on dose rate, field size and energy all had standard deviations smaller than 1%. The signal variation with the angle of incidence was smaller than 2% (1 SD). Measurements performed in clinical situations suggest the potential of using this real-time system for in vivo dosimetry in radiotherapy.
  •  
6.
  • Baldoc, C, et al. (författare)
  • Dose resolution in radiotherapy polymer gel dosimetry: effect of echo spacing in MRI pulse sequence
  • 2001
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 46:2, s. 449-460
  • Tidskriftsartikel (refereegranskat)abstract
    • In polymer gel dosimetry using magnetic resonance imaging, the uncertainty in absorbed dose is dependent on the experimental determination of T2. The concept of dose resolution (Dpdelta) of polymer gel dosimeters is developed and applied to the uncertainty in dose related to the uncertainty in T2 from a range of T4 encountered in polymer gel dosimetry. Dpdelta is defined as the minimal separation between two absorbed doses such that they may be distinguished with a given level of confidence, p. The minimum detectable dose (MDD) is Dpdelta as the dose approaches zero. Dpdelta and the minimum detectable dose both give a quantifiable indication of the likely practical limitations and usefulness of the dosimeter. Dpdelta of a polyacrylamide polymer gel dosimeter is presented for customized 32-echo and standard multiple-spin-echo sequences on a clinical MRI scanner. In evaluating uncertainties in T2, a parameter of particular significance in the pulse sequence is the echo spacing (ES). For optimal results, ES should be selected to minimize Dpdelta over a range of doses of interest in polymer gel dosimetry.
  •  
7.
  • Bergenwall, B., et al. (författare)
  • Experimental kerma coefficients for carbon deduced from microscopic cross sections at 96 MeV incident neutron energy
  • 2004
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 0031-9155 .- 1361-6560. ; 49:19, s. 4523-4542
  • Tidskriftsartikel (refereegranskat)abstract
    • The double-differential cross sections for (n, px), (n, dx), (n, tx), (n, (3)Hex) and (n, alphax) reactions in carbon have been measured at 96 MeV incident neutron energy. The various charged particles (inclusive spectra) were identified using A E-E techniques. From the experimental data, energy- and angle-differential as well as production cross sections were determined, and subsequently the partial and total kerma coefficients. The deduced partial and total kerma coefficients were compared to previous experimental results and theoretical calculations. The findings indicate that the deduced kerma coefficients for the hydrogen isotopes are in good agreement with those deduced from a previous measurement, and that the kerma coefficient values, in particular of the hydrogen isotopes, are systematically higher than values obtained from recent model calculations, which consequently resulted in a total kerma coefficient which is up to 30% higher than predicted by the calculations.
  •  
8.
  • Björk, Peter, et al. (författare)
  • Dosimetry characteristics of degraded electron beams investigated by Monte Carlo calculations in a setup for intraoperative radiation therapy.
  • 2002
  • Ingår i: Physics in Medicine and Biology. - : IOP Publishing. - 1361-6560 .- 0031-9155. ; 47:2, s. 239-256
  • Tidskriftsartikel (refereegranskat)abstract
    • Degraded electron beams, as used for intraoperative radiation therapy (IORT) or similar complicated dosimetric situations, have different characteristics compared to conventional electron therapy beams. If international dosimetry protocols are applied in a direct manner to such degraded beams, uncertainties will be introduced in the absorbed dose determination. The Monte Carlo method has been used to verify experimentally determined relative absorbed dose distributions and output factors in an IORT geometry. Monte Carlo generated dose distributions are mostly within +/-2% or +/-2 mm of measured data. The simulated output variation between the IORT cones (relative output factors) are mostly within 2% of measured values. By comparing IORT and conventional electron beam characteristics (e.g. energy spectra, angular distributions and the contributions of different system components to these quantities) limitations and uncertainties of commonly used dosimetric techniques in IORT electron fields are quantified. The intraoperative treatment field contains a larger amount of scattered electrons, which leads to a broader energy spectrum as well as a wider angular distribution of electrons at the phantom surface. The dose from the scattered electrons can contribute up to 40% of the total dose at a depth of dose maximum, compared to approximately 10% for standard beams. A study of the energy spectra at the reference depth reveals that an uncertainty of the order of 1% can be introduced if ionization chamber based dosimetry is used to determine output factors for the investigated IORT system. We recommend that relative absorbed dose distributions and output factors in IORT electron beams and for similar complicated dosimetric situations should be determined with detectors having a small energy and angular dependence (e.g. diamond detectors or p-Si diodes).
  •  
9.
  •  
10.
  •  