SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1383 875X OR L773:1572 8595 srt2:(2010-2014)"

Sökning: L773:1383 875X OR L773:1572 8595 > (2010-2014)

  • Resultat 1-5 av 5
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Härdén, Marie, et al. (författare)
  • Responsiveness of AF6, a new, short, validated, atrial fibrillation-specific questionnaire--symptomatic benefit of direct current cardioversion.
  • 2010
  • Ingår i: Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing. - : Springer Science and Business Media LLC. - 1572-8595. ; 28:3, s. 185-191
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives To measure the effects on symptoms of electrical cardioversion (DC) in patients with atrial fibrillation (AF) by means of a new, short, validated, AF-specific questionnaire, the AF6. Methods One hundred eleven patients (67 ± 12 years, 89 men) were screened before and 12 ± 3 days after DC using AF6, covering ‘breathing difficulties at rest’, ‘breathing difficulties on exertion’, ‘limitations in day-to-day life due to atrial fibrillation’, ‘feeling of discomfort due to atrial fibrillation’, ‘tiredness due to atrial fibrillation’, and ‘worry/anxiety due to atrial fibrillation’. A single global score was calculated. The Toronto AF Symptoms and Severity Check List (AFSS) and the generic SF-36 were also administered. Patients in sinus rhythm at 12 ± 3 days (n = 56) were defined as responders and patients in AF (n = 55) as non-responders. Results The mean single global score decreased in all patients (18 ± 12.4 to 13 ± 11.6, p < 0.0001) and in responders (22 ± 14 vs. 12 ± 12, p < 0.01) but not in non-responders (14 ± 9 vs. 14 ± 11, N.S). The AFSS frequency scores decreased from 14.5 ± 7.7 to 9.5 ± 7.8 in responders, p = 0.001, but not in non-responders. There was a strong correlation between changes in the AF6 and the SF-36 regarding four of the six items. Effect sizes of AF6 ranged from 0 to 0.52 in all patients, in responders from 0.10 to 0.85 and in non-responders from −0.23 to 0.34, the highest figures consistently referring to ‘tiredness due to atrial fibrillation’. Conclusions The symptom scores measured by AF6 decreased significantly, especially in responders. AF6 demonstrated adequate responsiveness to change, and effect sizes were mostly moderate, in responders moderate to high.
  •  
2.
  • Johansson, Birgitta, et al. (författare)
  • Atrial function after left atrial epicardial cryoablation for atrial fibrillation in patients undergoing mitral valve surgery
  • 2012
  • Ingår i: Journal of Interventional Cardiac Electrophysiology. - : Springer Science+Business Media B.V.. - 1383-875X .- 1572-8595. ; 33:1, s. 85-91
  • Tidskriftsartikel (refereegranskat)abstract
    • PURPOSE: To explore the effects on atrial and ventricular function of restoring sinus rhythm (SR) after epicardial cryoablation and closure of the left atrial appendage (LAA) in patients with mitral valve disease and atrial fibrillation (AF) undergoing surgery.METHODS: Sixty-five patients with permanent AF were randomized to mitral valve surgery combined with left atrial epicardial cryoablation and LAA closure (ABL group, n = 30) or to mitral valve surgery alone (control group, n = 35). Two-dimensional and Doppler echocardiography were performed before and 6 months after surgery.RESULTS: At 6 months, 73% of the patients in the ABL group and 46% of the controls were in SR. Patients in SR at 6 months had a reduction in their left ventricular diastolic diameter while the left ventricular ejection fraction was unchanged. In patients remaining in AF, the left ventricular ejection fraction was lower than at baseline. The left atrial diastolic volume was reduced after surgery, more in patients with SR than AF. In patients in SR, the peak velocity during the atrial contraction and the reservoir function were lower in the ABL group than in the control group.CONCLUSIONS: In patients in SR, signs of atrial dysfunction were observed in the ABL but not the control group. Atrial dysfunction may have existed before surgery, but the difference between the groups implies that the cryoablation procedure and/or closure of the LAA might have contributed.
  •  
3.
  • Ostrowska, Bozena, et al. (författare)
  • A novel variant in plakophilin-2 gene detected in a family with arrhythmogenic right ventricular cardiomyopathy
  • 2012
  • Ingår i: Journal of Interventional Cardiac Electrophysiology. - : Springer Science and Business Media LLC. - 1383-875X .- 1572-8595. ; 34:1, s. 11-18
  • Tidskriftsartikel (refereegranskat)abstract
    • AIMS: Arrhythmogenic right ventricular cardiomyopathy (ARVC) is characterized by fibrofatty replacement of muscular fibers predominantly in the right ventricle and with ventricular arrhythmias as the main clinical manifestation. Mutations in several components of the desmosome genes have been identified and mutations of the plakophilin-2 (PKP-2) gene are a common cause of ARVC. The aim of this study is to investigate the correlation between genotype and phenotype in a family with a novel PKP-2 variant.METHODS AND RESULTS: This study describes the clinical findings and genetic analysis in a family with ARVC. A part of the family has been followed clinically long term for up to 27 years. Two not previously reported PKP-2 variants (L506P and T526A) have been identified in this family. Even though all members of this family share the novel variant L506P, the clinical features, i.e., their phenotypes are different. The L506P variant is located in exon 7 and affects a highly conserved residue. The same amino acid, leucine, is present in all species evaluated, indicating a functional importance and the variant is predicted to be damaging. The novel L506P variant in the PKP-2 gene is thus a possible pathogenic alteration in the described family with ARVC. In contrast, the T526A variant is weakly conserved and predicted to be tolerated.CONCLUSION: While many of the reported ARVC mutations are truncating mutations, the possibly damaging variant found in this family, is a missense alteration affecting a highly conserved residue 506 located in exon 7.
  •  
4.
  • Sciaraffia, Elena, 1977-, et al. (författare)
  • The reliability of cardiogenic impedance and correlation with echocardiographic and plethysmographic parameters for predicting CRT time intervals post implantation
  • 2013
  • Ingår i: Journal of Interventional Cardiac Electrophysiology. - : Springer Science and Business Media LLC. - 1383-875X .- 1572-8595. ; 37:2, s. 155-162
  • Tidskriftsartikel (refereegranskat)abstract
    • AimsEncouraging data have been reported on the use of cardiogenic impedance (CI) in cardiac reshynchronization therapy (CRT) optimization. The purpose of this study was to: evaluate the stability of certain CI vectors 24 hours post implantation, study the correlation between these CI signals and selected echocardiographic parameters, examine the possibility of non-invasive calibration of patient-specific impedance-based prediction models.Methods and resultsThirteen patients received a CRT-D device with monitor capability of the dynamic impedance between several electrodes. At implantations patient-specific impedance-based prediction models were created for identification of optimal atrioventricular (AV) and interventricular (VV) delays and calibrated on invasive measurements of left ventricular contractility (LV dP/dtmax). Simultaneously non-invasive measurements of LV dP/dtmax and stroke volume (SV) were obtained using a finger plethysmograph. Patients were re-evaluated with echocardiography and new CI measurements the day after implantation.The haemodynamic benefit achieved by optimal VV setting according to the patient-specific impedance-based prediction models at follow-up was not as large as the one obtained at implantation. In a multivariate partial least square regression analysis a correlation was found between aortic VTI and a generic linear combination of CI features (P<0,005). No correlation was found between the patient-specific impedance-based prediction models and the non-invasive measurements of LV dP/dtmax and SV.ConclusionsCardiogenic impedance signals can be used to optimize CRT settings but seems less feasible as an ambulatory tool since calibration is required. The positive correlation between aortic-VTI and CI measurements seems promising; although a larger cohort is required to create an echocardiography-based patient-specific model.
  •  
5.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-5 av 5

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy