SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "L773:1473 0502 OR L773:1878 1683 srt2:(2015-2019)"

Sökning: L773:1473 0502 OR L773:1878 1683 > (2015-2019)

  • Resultat 1-10 av 12
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Aardal-Eriksson, Elisabeth, et al. (författare)
  • Iron depletion in blood donors - Have extended erythrocyte and reticulocyte parameters diagnostic utility?
  • 2015
  • Ingår i: Transfusion and apheresis science. - : PERGAMON-ELSEVIER SCIENCE LTD. - 1473-0502 .- 1878-1683. ; 53:1, s. 76-81
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Blood donation is associated with iron depletion, but donor iron status is not usually investigated, as such tests are cumbersome and costly. It would therefore be desirable to have simple, fast and inexpensive tests that give information on a donors risk of developing iron depletion. In a pilot study we investigated whether novel erythrocyte and reticulocyte parameters can serve this goal. Methods: In regular blood donors extended red cell parameters were measured using the Abbott CELL-DYN Sapphire hematology analyzer and conventional biochemical tests of iron status. Donors were compared with a regionally matched group of non-donating controls. Results: In the controls, the reference ranges of extended RBC parameters were well comparable to published data. Donors had significantly more microcytic RBC than controls (median 0.9 vs 0.6%), lower serum ferritin concentration (median 43 vs 91 mg/L) and higher soluble transferrin receptor/ferritin index (median 1.60 vs 1.27). Overall 18-28% of the donors were iron depleted. Moreover, 3.3% of donors had iron-restricted erythropoiesis. Microcytic RBC and reticulocyte mean cell hemoglobin content predicted iron depletion with 70% and 64% sensitivities and specificities of 72% and 78%, respectively. When combined these two parameters increased the sensitivity to 82%. Conclusions: Our results in Swedish blood donors confirm a high prevalence of iron depletion, despite iron supplementation used by about half of the donors. Microcytic RBC and MCHr appeared to be helpful in identifying iron-depleted donors, who might benefit from iron supplementation. We recommend larger prospective investigations in order to confirm and extend the findings of this pilot study. (C) 2015 Elsevier Ltd. All rights reserved.
  •  
2.
  • Burnouf, Thierry, et al. (författare)
  • Viral safety of human platelet lysate for cell therapy and regenerative medicine : Moving forward, yes, but without forgetting the past
  • 2019
  • Ingår i: Transfusion and apheresis science. - : PERGAMON-ELSEVIER SCIENCE LTD. - 1473-0502 .- 1878-1683. ; 58:6
  • Forskningsöversikt (refereegranskat)abstract
    • Growth factor-rich pooled human platelet lysate (HPL), made from human platelet concentrates, is one new blood-derived bioproduct that is attracting justified interest as a xeno-free supplement of growth media for human cell propagation for cell therapy. HPL can also find potentially relevant applications in the field of regenerative medicine. Therefore, the therapeutic applications of HPL go far beyond the standard clinical applications of the traditional blood products typically used in patients suffering from life-threatening congenital or acquired deficiencies in cellular components or proteins due to severe genetic diseases or trauma. A wider population of patients, suffering from various pathologies than has traditionally been the case, is thus, now susceptible to receiving a human blood-derived product. These patients would, therefore, be exposed to the possible, but avoidable, side effects of blood products, including transfusion-transmitted infections, most specifically virus transmissions. Unfortunately, not all manufacturers, suppliers, and users of HPL may have a strong background in the blood product industry. As such, they may not be fully aware of the various building blocks that should contribute to the viral safety of HPL as is already the case for any licensed blood products. The purpose of this manuscript is to reemphasize all the measures, including in regulatory aspects, capable of assuring that HPL exhibits a sufficient pathogen safety margin, especially when made from large pools of human platelet concentrates. It is vital to remember the past to avoid that the mistakes, which happened 30 to 40 years ago and led to the contamination of many blood recipients, be repeated due to negligence or ignorance of the facts.
  •  
3.
  • Lappegård, Knut Tore, et al. (författare)
  • Lipoprotein apheresis affects lipoprotein particle subclasses more efficiently compared to the PCSK9 inhibitor evolocumab, a pilot study.
  • 2018
  • Ingår i: Transfusion and apheresis science. - : Elsevier BV. - 1473-0502 .- 1878-1683. ; 57:1, s. 91-96
  • Tidskriftsartikel (refereegranskat)abstract
    • Lipoprotein apheresis and proprotein convertase subtilisin/kexin type 9 (PCSK9) inhibitors are last therapeutic resorts in patients with familial hypercholesterolemia (FH). We explored changes in lipoprotein subclasses and high-density lipoprotein (HDL) function when changing treatment from lipoprotein apheresis to PCSK9 inhibition. We measured the levels of low-density lipoprotein (LDL) and HDL particle subclasses, serum amyloid A1 (SAA1), paraoxonase-1 (PON1) activity and cholesterol efflux capacity (CEC) in three heterozygous FH patients. Concentrations of all LDL particle subclasses were reduced during apheresis (large 68.0 ± 17.5 to 16.3 ± 2.1 mg/dL, (p = 0.03), intermediate 38.3 ± 0.6 to 5.0 ± 3.5 mg/dL (p = 0.004) and small 5.0 ± 2.6 to 0.2 ± 0.1 mg/dL (p = 0.08)). There were non-significant reductions in the LDL subclasses during evolocumab treatment. There were non-significant reductions in subclasses of HDL particles during apheresis, and no changes during evolocumab treatment. CEC was unchanged throughout the study, while the SAA1/PON1 ratio was unchanged during apheresis but decreased during evolocumab treatment. In conclusion, there were significant reductions in large and intermediate size LDL particles during apheresis, and a non-significant reduction in small LDL particles. There were only non-significant reductions in the LDL subclasses during evolocumab treatment.
  •  
4.
  • Mörtzell Henriksson, Monica, et al. (författare)
  • Adverse events in apheresis : an update of the WAA registry data
  • 2016
  • Ingår i: Transfusion and apheresis science. - : Elsevier. - 1473-0502 .- 1878-1683. ; 54:1, s. 2-15
  • Forskningsöversikt (refereegranskat)abstract
    • Apheresis with different procedures and devices are used for a variety of indications that may have different adverse events (AEs). The aim of this study was to clarify the extent and possible reasons of various side effects based on data from a multinational registry. The WAA-apheresis registry data focus on adverse events in a total of 50846 procedures in 7142 patients (42% women). AEs were graded as mild, moderate (need for medication), severe (interruption due to the AE) or death (due to AE). More AEs occurred during the first procedures versus subsequent (8.4 and 5.5%, respectively). AEs were mild in 2.4% (due to access 54%, device 7%, hypotension 15%, tingling 8%), moderate in 3% (tingling 58%, urticaria 15%, hypotension 10%, nausea 3%), and severe in 0.4% of procedures (syncope/hypotension 32%, urticaria 17%, chills/fever 8%, arrhythmia/asystole 4.5%, nausea/vomiting 4%). Hypotension was most common if albumin was used as the replacement fluid, and urticaria when plasma was used. Arrhythmia occurred to similar extents when using plasma or albumin as replacement. In 64% of procedures with bronchospasm, plasma was part of the replacement fluid used. Severe AEs are rare. Although most reactions are mild and moderate, several side effects may be critical for the patient. We present side effects in relation to the procedures and suggest that safety is increased by regular vital sign measurements, cardiac monitoring and by having emergency equipment nearby.
  •  
5.
  • Sellberg, Felix, et al. (författare)
  • Composition of growth factors and cytokines in lysates obtained from fresh versus stored pathogen-inactivated platelet units
  • 2016
  • Ingår i: Transfusion and apheresis science. - : Elsevier BV. - 1473-0502 .- 1878-1683. ; 55:3, s. 333-337
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Platelet lysate is a readily available source of growth factors, and other mediators, which has been used in a variety of clinical applications. However, the product remains poorly standardized and the present investigation evaluates the composition of platelet lysate obtained from either fresh or stored pathogen-inactivated platelet units.Materials and Methods: Platelet pooled units (n = 10) were obtained from healthy blood donors and tested according to standard procedures. All units were pathogen inactivated using amotosalen hydrochloride and UVA exposure. Platelet lysate was subsequently produced at two separate time-points, either from fresh platelet units or after 5 days of storage, by repeated freeze-thaw cycles. The following mediators were determined at each time point: EGF, FGF-2, VEGF, IGF-1, PDGF-AB/BB, BMP-2, PF4, TGF-beta isoform 1, IL-1(i, IL-2, IL-6, IL-10, IL-12p70, 1L-17A, TNF-alpha, and IFN-gamma.Results: The concentration of growth factors and cytokines was affected by time in storage. Notably, TGF-beta, PDGF-AB/BB, and PF4 showed an increase of 27.2% (p < 0.0001), 29.5% (p = 0.04) and 8.2% (p = 0.0004), respectively. A decrease was seen in the levels of IGF-1 and FGF-2 with 22% (p = 0.041) and 11% (p = 0.01), respectively. Cytokines were present only in very low concentrations and all other growth factors remained stable with time in storage.Conclusion: The composition of mediators in platelet lysate obtained from pathogen inactivated platelet units differs when produced from fresh and stored platelet units, respectively. This underscores the need for further standardization and optimization of this important product, which potentially may influence the clinical effects.
  •  
6.
  •  
7.
  •  
8.
  • Stegmayr, Bernd, et al. (författare)
  • Distribution of indications and procedures within the framework of centers participating in the WAA apheresis registry
  • 2017
  • Ingår i: Transfusion and apheresis science. - : Elsevier BV. - 1473-0502 .- 1878-1683. ; 56:1, s. 71-74
  • Tidskriftsartikel (refereegranskat)abstract
    • The WAA apheresis registry was established in 2003 and an increasing number of centers have since then included their experience and data of their procedures. The registry now contains data of more than 74,000 apheresis procedures in more than 10,000 patients. This report shows that the indications for apheresis procedures are changing towards more oncological diagnoses and stem cell collections from patients and donors and less therapeutic apheresis procedures. In centers that continue to register, the total extent of apheresis procedures and patients treated have expanded during the latest years.
  •  
9.
  • Stegmayr, Bernd (författare)
  • The World Apheresis Association Registry
  • 2017
  • Ingår i: Transfusion and apheresis science. - : Elsevier BV. - 1473-0502 .- 1878-1683. ; 56:1, s. 69-70
  • Forskningsöversikt (refereegranskat)
  •  
10.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-10 av 12

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy