1.
  • Abtahi, Farhad, 1981-, et al. (författare)
  • Development and preliminary evaluation of an Android based heart rate variability biofeedback system
  • 2014
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2014 36th Annual International Conference of the IEEE. - : IEEE. - 9781424479290 ; 2014, s. 3382-5
  • Konferensbidrag (refereegranskat)abstract
    • The reduced Heart Rate Variability (HRV) is believed to be associated with several diseases such as congestive heart failure, diabetes and chronic kidney diseases (CKD). In these cases, HRV biofeedback may be a potential intervention method to increase HRV which in turn is beneficial to these patients. In this work, a real-time Android biofeedback application based on a Bluetooth enabled ECG and thoracic electrical bioimpedance (respiration) measurement device has been developed. The system performance and usability have been evaluated in a brief study with eight healthy volunteers. The result demonstrates real-time performance of system and positive effects of biofeedback training session by increased HRV and reduced heart rate. Further development of the application and training protocol is ongoing to investigate duration of training session to find an optimum length and interval of biofeedback sessions to use in potential interventions.
  •  
2.
  • Atefi, Seyed Reza, 1985-, et al. (författare)
  • Cole Function and Conductance-Based Parasitic Capacitance Compensation for Cerebral Electrical Bioimpedance Measurements
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - San Diego : IEEE press. ; 2012, s. 3368-71
  • Konferensbidrag (refereegranskat)abstract
    • One of the most common measurement artifacts present in Electrical Bioimpedance Spectroscopy measurements (EBIS) comes from the capacitive leakage effect resulting from parasitic stray capacitances. This artifact produces a deviation in the measured impedance spectrum that is most noticeable at higher frequencies. The artifact taints the spectroscopy measurement increasing the difficulty of producing reliable EBIS measurements at high frequencies. In this work, an approach for removing such capacitive influence from the spectral measurement is presented making use of a novel method to estimate the value of the parasitic capacitance equivalent that causes the measurement artifact. The proposed method has been tested and validated theoretically and experimentally and it gives a more accurate estimation of the value of the parasitic capacitance than the previous methods. Once a reliable value of parasitic capacitance has been estimated the capacitive influence can be easily compensated in the EBIS measured data. Thus enabling analysis of EBIS data at higher frequencies, i.e. in the range of 300-500 kHz like measurements intended for cerebral monitoring, where the characteristic frequency is remarkably higher than EBIS measurements i.e. within the range 30 to 50 kHz, intended for body composition assessment.
  •  
3.
  • Atefi, Seyed Reza, 1985-, et al. (författare)
  • Electrical Bioimpedance cerebral monitoring. Preliminary results from measurements on stroke patients
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 126-9
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance Spectroscopy (EBIS) is currently used in different tissue characterization applications. In this work we aim to use EBIS to study changes in electrical properties of the cerebral tissues after an incident of hemorrhage/ischemic stroke. To do so a case-control study was conducted using six controls and three stroke cases. The preliminary results of this study show that by using Cole-based analysis on EBIS measurements and analyzing the Cole parameters R0 and R∞, it is possible to detect changes on electrical properties of cerebral tissue after stroke. 
  •  
4.
  •  
5.
  • Fernández-Alemán, José Luis, et al. (författare)
  • An analysis of free Web-based PHRs functionalities and I18n.
  • 2012
  • Ingår i: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. - 2694-0604. ; 2012, s. 1282-5
  • Tidskriftsartikel (refereegranskat)abstract
    • The growth of the Internet, Web technologies, and other electronic tools are allowing the public to become more informed and actively engaged in their health care than was possible in the past. Personal Health Records (PHR) offer users possibility of managing their own health data. Many patients are using PHRs to communicate with doctors in order to improve healthcare quality and efficiency. A large number of companies have emerged to provide consumers with the opportunity to use online PHRs within a healthcare platform, proposing different functionalities and services. This paper analyzes and assesses the functionalities and internationalization (i18n) of free Web based PHRs.
  •  
6.
  •  
7.
  • Ferreira, J., et al. (författare)
  • Portable bioimpedance monitor evaluation for continuous impedance measurements : Towards wearable plethysmography applications
  • 2013
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - 9781457702167 ; 2013, s. 559-62
  • Konferensbidrag (refereegranskat)abstract
    • Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.
  •  
8.
  • Marquez Ruiz, Juan Carlos, et al. (författare)
  • Skin-Electrode Contact Area in Electrical Bioimpedance Spectroscopy. Influence in Total Body Composition Assessment.
  • 2011
  • Ingår i: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. - : IEEE. - 9781424441228 ; 2011, s. 1867-70
  • Konferensbidrag (refereegranskat)abstract
    • Electrical Bioimpedance Spectroscopy (EBIS) has been widely use for assessment of total body composition and fluid distribution. (EBIS) measurements are commonly performed with electrolytic electrodes placed on the wrist and the ankle with a rather small skin–electrode contact area. The use of textile garments for EBI requires the integration of textrodes with a larger contact area surrounding the limbs in order to compensate the absence of electrolytic medium commonly present in traditional Ag/AgCl gel electrodes. Recently it has been shown that mismatch between the measurements electrodes might cause alterations on the EBIS measurements. When performing EBIS measurements with textrodes certain differences have been observed, especially at high frequencies, respect the same EBIS measurements using Ag/AgCl electrodes. In this work the influence of increasing the skinelectrode area on the estimation of body composition parameters has been study performing experimental EBIS measurement. The results indicate that an increment on the area of the skin-electrode interface did produce noticeable changes in the bioimpedance spectra as well as in the body composition parameters. This influence must be taken into consideration when designing and testing textile-enable EBIS measurement systems.
  •  
9.
  • Ouhbi, Sofia, et al. (författare)
  • Electronic health records for cardiovascular medicine.
  • 2014
  • Ingår i: Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference. - 2694-0604. ; 2014, s. 1354-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Nowadays, many cardiology health care centers and hospitals adopt new technologies to improve interaction with their patients. The Electronic Health Records (EHR) offer health care centers and institutions the possibility to improve the management of their patients' health data. Currently, many physicians are using EHRs to improve health care quality and efficiency. A large number of companies have emerged to provide hospitals with the opportunity to adopt EHRs within a health care platform proposing different functionalities and services which achieve certain certification criteria. This paper identifies the current list of certified EHRs for cardiovascular medicine and assesses the specifications of the EHRs selected. The result of this paper may assist EHR seekers for cardiovascular medicine in their tasks.
  •  
10.
  • Seoane, Fernando, 1976-, et al. (författare)
  • Adaptive frequency distribution for Electrical Bioimpedance Spectroscopy measurements
  • 2012
  • Ingår i: Engineering in Medicine and Biology Society (EMBC), 2012 Annual International Conference of the IEEE. - : IEEE. - 9781424441198 ; 2012, s. 562-5
  • Konferensbidrag (refereegranskat)abstract
    • This paper presents a novel frequency distribution scheme intended to provide more accurate estimations of Cole parameters. Nowadays a logarithmic frequency distribution is mostly used in Electrical Bioimpedance Spectroscopy (EBIS) applications. However it is not optimized following any criterion. Our hypothesis is that an EBIS signal contains more information where the variation of the measurement regarding the frequency is larger; and that there ought to be more measuring frequencies where there is more information. Results show that for EBIS data with characteristic frequencies up to 200 kHz the error obtained with both frequency distribution schemes is similar. However, for EBIS data with higher values of characteristic frequency the error produced when estimating the values from EBIS measurements using an adaptive frequency distribution is smaller. Thus it may useful for EBIS applications with high values of characteristic frequency, e.g. cerebral bioimpedance.
  •  