1.
  • Aakre, Kristin M, et al. (författare)
  • Lower Limits for Reporting High-Sensitivity Cardiac Troponin Assays and Impact of Analytical Performance on Patient Misclassification.
  • 2024
  • Ingår i: Clinical chemistry. - 0009-9147 .- 1530-8561. ; 70:3, s. 497-505
  • Tidskriftsartikel (refereegranskat)abstract
    • Cardiac troponin measurements are indispensable for the diagnosis of myocardial infarction and provide useful information for long-term risk prediction of cardiovascular disease. Accelerated diagnostic pathways prevent unnecessary hospital admission, but require reporting cardiac troponin concentrations at low concentrations that are sometimes below the limit of quantification. Whether analytical imprecision at these concentrations contributes to misclassification of patients is debated.The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) provides evidence-based educational statements on analytical and clinical aspects of cardiac biomarkers. This mini-review discusses how the reporting of low concentrations of cardiac troponins impacts on whether or not assays are classified as high-sensitivity and how analytical performance at low concentrations influences the utility of troponins in accelerated diagnostic pathways. Practical suggestions are made for laboratories regarding analytical quality assessment of cardiac troponin results at low cutoffs, with a particular focus on accelerated diagnostic pathways. The review also discusses how future use of cardiac troponins for long-term prediction or management of cardiovascular disease may require improvements in analytical quality.Clinical guidelines recommend using cardiac troponin concentrations as low as the limit of detection of the assay to guide patient care. Laboratories, manufacturers, researchers, and external quality assessment providers should extend analytical performance monitoring of cardiac troponin assays to include the concentration ranges applicable in these pathways.
  •  
2.
  • Steiro, Ole-Thomas, et al. (författare)
  • Prognostic significance of chronic myocardial injury diagnosed by three different cardiac troponin assays in patients admitted with suspected acute coronary syndrome
  • 2024
  • Ingår i: Clinical Chemistry and Laboratory Medicine. - : Walter de Gruyter. - 1434-6621 .- 1437-4331. ; 62:4, s. 729-739
  • Tidskriftsartikel (refereegranskat)abstract
    • Objectives:Chronic myocardial injury (CMI) is defined as stable concentrations of cardiac troponin T or I (cTnT or cTnI) above the assay-specific 99th percentile upper reference limit (URL) and signals poor outcome. The clinical implications of diagnosing CMI are unclear. We aimed to assess prevalence and association of CMI with long-term prognosis using three different high-sensitivity cTn (hs-cTn) assays.Methods:A total of 1,292 hospitalized patients without acute myocardial injury had cTn concentrations quantified by hs-cTn assays by Roche Diagnostics, Abbott Diagnostics and Siemens Healthineers. The median follow-up time was 4.1 years. The prevalence of CMI and hazard ratios for mortality and cardiovascular (CV) events were calculated based on the URL provided by the manufacturers and compared to the prognostic accuracy when lower percentiles of cTn (97.5, 95 or 90), limit of detection or the estimated bioequivalent concentrations between assays were used as cutoff values.Results:There was no major difference in prognostic accuracy between cTnT and cTnI analyzed as continuous variables. The correlation between cTnT and cTnI was high (r=0.724-0.785), but the cTnT assay diagnosed 3.9-4.5 times more patients with having CMI based on the sex-specific URLs (TnT, n=207; TnI Abbott, n=46, TnI Siemens, n=53) and had higher clinical sensitivity and AUC at the URL.Conclusions:The prevalence of CMI is highly assay-dependent. cTnT and cTnI have similar prognostic accuracy for mortality or CV events when measured as continuous variables. However, a CMI diagnosis according to cTnT has higher prognostic accuracy compared to a CMI diagnosis according to cTnI.
  •  