SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Alian F)
 

Sökning: WFRF:(Alian F) > (2010-2014) > Prosthetic Reconstr...

Prosthetic Reconstruction from the Tympanic Membrane to the Stapes Head or to the Stapes Footplate? A Laser Doppler Study

Alian, Wael A, 1970 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology
Majdalawieh, O. F. (författare)
Van Wijhe, R. G. (författare)
visa fler...
Ejnell, Hasse, 1948 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för öron-, näs- och halssjukdomar,Institute of Clinical Sciences, Department of Otorhinolaryngology
Bance, M. (författare)
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: Journal of Otolaryngology-Head & Neck Surgery. - 1916-0216. ; 41:2, s. 84-93
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: In the absence of the incus, many surgeons believe that reconstruction from the tympanic membrane to the stapes head is more effective than reconstruction to the stapes footplate. This has rarely been tested empirically. Published better clinical results with reconstruction to the stapes head might simply reflect less underlying disease in ears with an intact stapes superstructure. Objective: To compare vibration transmission of these two forms of prosthetic reconstruction. Methods: A fresh human cadaveric temporal bone model was used. Round window vibrations in response to sound in the ear canal were measured with a laser Doppler vibrometer. After incus removal, the discontinuity was repaired using a titanium prosthesis. Reconstruction from the tympanic membrane to the stapes head was compared to reconstruction to the stapes footplate. Results: Reconstruction of both types decreased round window vibrations by 10 to 15 dB between 500 and 3000 Hz compared to the intact middle ear. Reconstruction to the stapes head performed 5 to 10 dB better at lower frequencies (500-2000 Hz), but this was only statistically significant at 1 and 2 kHz. Conclusions: There is only a 5 to 10 dB mechanical advantage gained by reconstruction from the tympanic membrane to the stapes head compared to reconstruction to the footplate for frequencies between 1 and 2 kHz.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)

Nyckelord

laser Doppler vibrometry
middle ear mechanics
ossiculoplasty
partial
ossicular replacement prosthesis
titanium prosthesis
total ossicular
replacement prosthesis
human middle-ear
ossicular chain reconstruction
malleus-to-footplate
intact stapes
temporal bone
ossiculoplasty
tympanoplasty
implants
model
torps

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy