SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Alpert N) srt2:(2015-2019)"

Sökning: WFRF:(Alpert N) > (2015-2019)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  • Doriese, W B, et al. (författare)
  • A practical superconducting-microcalorimeter X-ray spectrometer for beamline and laboratory science
  • 2017
  • Ingår i: Review of Scientific Instruments. - : AIP Publishing. - 0034-6748 .- 1089-7623. ; 88:5
  • Tidskriftsartikel (refereegranskat)abstract
    • We describe a series of microcalorimeter X-ray spectrometers designed for a broad suite of measurement applications. The chief advantage of this type of spectrometer is that it can be orders of magnitude more efficient at collecting X-rays than more traditional high-resolution spectrometers that rely on wavelength-dispersive techniques. This advantage is most useful in applications that are traditionally photon-starved and/or involve radiation-sensitive samples. Each energy-dispersive spectrometer is built around an array of several hundred transition-edge sensors (TESs). TESs are superconducting thin films that are biased into their superconducting-to-normal-metal transitions. The spectrometers share a common readout architecture and many design elements, such as a compact, 65 mK detector package, 8-column time-division-multiplexed superconducting quantum-interference device readout, and a liquid-cryogen-free cryogenic system that is a two-stage adiabatic-demagnetization refrigerator backed by a pulse-tube cryocooler. We have adapted this flexible architecture to mate to a variety of sample chambers and measurement systems that encompass a range of observing geometries. There are two different types of TES pixels employed. The first, designed for X-ray energies below 10 keV, has a best demonstrated energy resolution of 2.1 eV (full-width-at-half-maximum or FWHM) at 5.9 keV. The second, designed for X-ray energies below 2 keV, has a best demonstrated resolution of 1.0 eV (FWHM) at 500 eV. Our team has now deployed seven of these X-ray spectrometers to a variety of light sources, accelerator facilities, and laboratory-scale experiments; these seven spectrometers have already performed measurements related to their applications. Another five of these spectrometers will come online in the near future. We have applied our TES spectrometers to the following measurement applications: synchrotron-based absorption and emission spectroscopy and energy-resolved scattering; accelerator-based spectroscopy of hadronic atoms and particle-induced-emission spectroscopy; laboratory-based time-resolved absorption and emission spectroscopy with a tabletop, broadband source; and laboratory-based metrology of X-ray-emission lines. Here, we discuss the design, construction, and operation of our TES spectrometers and show first-light measurements from the various systems. Finally, because X-ray-TES technology continues to mature, we discuss improvements to array size, energy resolution, and counting speed that we anticipate in our next generation of TES-X-ray spectrometers and beyond.
  •  
4.
  • Druwé, Patrick, et al. (författare)
  • Perception of inappropriate cardiopulmonary resuscitation by clinicians working in emergency departments and ambulance services : The REAPPROPRIATE international, multi-centre, cross sectional survey
  • 2018
  • Ingår i: Resuscitation. - : Elsevier. - 0300-9572 .- 1873-1570. ; 132, s. 112-119
  • Tidskriftsartikel (refereegranskat)abstract
    • Introduction: Cardiopulmonary resuscitation (CPR) is often started irrespective of comorbidity or cause of arrest. We aimed to determine the prevalence of perception of inappropriate CPR of the last cardiac arrest encountered by clinicians working in emergency departments and out-of-hospital, factors associated with perception, and its relation to patient outcome.Methods: A cross-sectional survey was conducted in 288 centres in 24 countries. Factors associated with perception of CPR and outcome were analyzed by Cochran-Mantel-Haenszel tests and conditional logistic models.Results: Of the 4018 participating clinicians, 3150 (78.4%) perceived their last CPR attempt as appropriate, 548 (13.6%) were uncertain about its appropriateness and 320 (8.0%) perceived inappropriateness; survival to hospital discharge was 370/2412 (15.3%), 8/481 (1.7%) and 8/294 (2.7%) respectively. After adjusting for country, team and clinician's characteristics, the prevalence of perception of inappropriate CPR was higher for a non-shockable initial rhythm (OR 3.76 [2.13-6.64]; P < .0001), a non-witnessed arrest (2.68 [1.89-3.79]; P < .0001), in older patients (2.94 [2.18-3.96]; P < .0001, for patients > 79 years) and in case of a "poor" first physical impression of the patient (3.45 [2.36-5.05]; P < .0001). In accordance, non-shockable and non-witnessed arrests were both associated with lower survival to hospital discharge (0.33 [0.26 - 0.41]; P < 0.0001 and 0.25 [0.15 - 0.41]; P < 0.0001, respectively), as were older patient age (0.25 [0.14 - 0.44]; P < 0.0001 for patients > 79 years) and a "poor" first physical impression (0.26 [0.19-0.35]; P < 0.0001).Conclusions: The perception of inappropriate CPR increased when objective indicators of poor prognosis were present and was associated with a low survival to hospital discharge. Factoring clinical judgment into the decision to (not) attempt CPR may reduce harm inflicted by excessive resuscitation attempts.
  •  
5.
  • O’Neil, Galen C., et al. (författare)
  • Ultrafast Time-Resolved X-ray Absorption Spectroscopy of Ferrioxalate Photolysis with a Laser Plasma X-ray Source and Microcalorimeter Array
  • 2017
  • Ingår i: The Journal of Physical Chemistry Letters. - : American Chemical Society (ACS). - 1948-7185. ; 8:5, s. 1099-1104
  • Tidskriftsartikel (refereegranskat)abstract
    • The detailed pathways of photoactivity on ultrafast time scales are a topic of contemporary interest. Using a tabletop apparatus based on a laser plasma X-ray source and an array of cryogenic microcalorimeter X-ray detectors, we measured a transient X-ray absorption spectrum during the ferrioxalate photoreduction reaction. With these high-efficiency detectors, we observe the Fe K edge move to lower energies and the amplitude of the extended X-ray absorption fine structure reduce, consistent with a photoreduction mechanism in which electron transfer precedes disassociation. These results are compared to previously published transient X-ray absorption measurements on the same reaction and found to be consistent with the results from Ogi et al. and inconsistent with the results of Chen et al. (Ogi, Y.; et al. Struct. Dyn. 2015, 2, 034901; Chen, J.; Zhang, H.; Tomov, I. V.; Ding, X.; Rentzepis, P. M. Chem. Phys. Lett. 2007, 437, 50-55). We provide quantitative limits on the Fe-O bond length change. Finally, we review potential improvements to our measurement technique, highlighting the future potential of tabletop X-ray science using microcalorimeter sensors.
  •  
6.
  • Petrov, Dmitry, et al. (författare)
  • Machine Learning for Large-Scale Quality Control of 3D Shape Models in Neuroimaging
  • 2017
  • Ingår i: Machine learning in medical imaging. MLMI (Workshop). - Cham : Springer International Publishing. ; 10541, s. 371-378
  • Tidskriftsartikel (refereegranskat)abstract
    • As very large studies of complex neuroimaging phenotypes become more common, human quality assessment of MRI-derived data remains one of the last major bottlenecks. Few attempts have so far been made to address this issue with machine learning. In this work, we optimize predictive models of quality for meshes representing deep brain structure shapes. We use standard vertex-wise and global shape features computed homologously across 19 cohorts and over 7500 human-rated subjects, training kernelized Support Vector Machine and Gradient Boosted Decision Trees classifiers to detect meshes of failing quality. Our models generalize across datasets and diseases, reducing human workload by 30-70%, or equivalently hundreds of human rater hours for datasets of comparable size, with recall rates approaching inter-rater reliability.
  •  
7.
  • Ullom, J N (creator_code:cre_t)
  • X-ray Spectrometer
  • 2019
  • Patent (övrigt vetenskapligt/konstnärligt)abstract
    • An x-ray spectrometer includes: an x-ray plasma source that produces first x-rays; an x-ray optic in optical communication with the x-ray plasma source and that: receives the first x-rays from the x-ray plasma source; focuses the first x-rays to produce second x-rays; and communicates the second x-rays to a sample that produces product x-rays in response to receipt of the second x-rays and second light; and a microcalorimeter array detector in optical communication with the sample and that receives the product x-rays from the sample.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy