SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Aneman A) srt2:(2000-2004)"

Sökning: WFRF:(Aneman A) > (2000-2004)

  • Resultat 1-7 av 7
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  •  
2.
  •  
3.
  •  
4.
  • Broome, M., et al. (författare)
  • Acute effects of angiotensin II on myocardial performance
  • 2001
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 45:9, s. 1147-54
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Specific angiotensin II (Ang II) receptors exist in many organs including peripheral blood vessels, cardiac myocytes and the central nervous system. This suggests multiple sites of actions for Ang II throughout the cardiovascular system. Cardiac effects of Ang II are not completely understood, though its prominent vasoconstrictor actions are well described. This study was designed to assess left ventricular function during administration of Ang II using relatively load-independent methods in a whole-animal model. METHODS: Ang II was infused in incremental doses (0-200 microg x h(-1)) in anaesthetised instrumented pigs (n=10). Cardiac systolic and diastolic function were evaluated by analysis of the left ventricular pressure-volume relationship. RESULTS: Heart rate (HR), mean arterial pressure (MAP) and systemic vascular resistance (SVR) increased dose-dependently with Ang II, while cardiac output (CO) remained unchanged. Systolic function indices, end-systolic elastance (Ees) and preload recruitable stroke work (PRSW), demonstrated dose-dependent increases. The diastolic function parameter tau (tau) did not change with increasing Ang II dose. CONCLUSION: Ang II infusion caused increases in contractility indices in anaesthetised pigs in the doses used in this study. The mechanisms for these systolic function effects may be a direct myocardial effect or modulated through changes in autonomic nervous system activity.
  •  
5.
  • Broome, M., et al. (författare)
  • Angiotensin II mesenteric and renal vasoregulation : dissimilar modulatory effects with nitroprusside
  • 2000
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 44:10, s. 1238-45
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: The role of systemic arterial pressure for the vascular effects of angiotensin II (Ang II) and the interactions between Ang II and perfusion pressure-dependent local vascular control mechanisms are not well understood. This study addresses these aspects of exogenous Ang II in the mesenteric and renal regional circulations. METHODS: Ang II was infused in incremental doses (0-200 microg/h) in anesthetized instrumented pigs (n=10). Renal and portal blood flows were measured by perivascular ultrasound. In the second part of the study, sodium nitroprusside (SNP) was infused at doses titrated to keep mean arterial pressure constant, in spite of concurrent Ang II administration. RESULTS: Powerful dose-dependent vasoconstrictions by Ang II were found in renal and mesenteric vascular beds (at highest Ang II doses vascular resistances increased by 109% and 88% respectively). Ang II-induced vasoconstriction was fully inhibited in the mesenteric, but not in the renal circulation, during conditions of constant mean arterial pressures achieved by SNP infusion. CONCLUSIONS: Mesenteric, but not renal, vasoconstriction by Ang II was inhibited by pharmacological maintenance of perfusion pressure. This could reflect differences between these vascular beds as regards the importance of co-acting myogenic pressure-dependent vasoconstriction. Alternatively, as the drug chosen for pressure control, sodium nitroprusside, serves as a nitric oxide donor, the relative balance between nitric oxide-mediated vasodilation and Ang II-induced vasoconstriction could have regional differences.
  •  
6.
  • Broome, Michael, et al. (författare)
  • Splanchnic vasoconstriction by angiotensin II is arterial pressure dependent
  • 2002
  • Ingår i: Acta Anaesthesiologica Scandinavica. - : Wiley. - 0001-5172 .- 1399-6576. ; 46:1, s. 57-63
  • Tidskriftsartikel (refereegranskat)abstract
    • BACKGROUND: Our hypothesis was that splanchnic vasoconstriction by exogenous angiotensin II (Ang II) is significantly potentiated by local mechanisms increasing vasomotor tone and that splanchnic tissue oxygenation during administration of Ang II is perfusion pressure dependent. The aim was to study local splanchnic circulatory effects and tissue oxygenation during intravenous infusion of Ang II at different levels of regional arterial driving pressure in a whole-body large animal model. METHODS: Ang II was infused in incremental doses (0-200 microg x h-1) in anaesthetised instrumented pigs (n=8). Mean superior mesenteric arterial pressure (PSMA) was adjusted by a local variable perivascular occluder. Perivascular ultrasound and laser-Doppler flowmetry were used for measurements of mesenteric venous blood flow and superficial intestinal blood flow, respectively. Intestinal oxygenation was evaluated by oxygen tissue tension (PtiO2) and lactate fluxes. RESULTS: Ang II produced prominent and dose-dependent increases in mesenteric vascular resistance (RSMA) when the intestine was exposed to systemic arterial pressure, but Ang II increased RSMA only minimally when PSMA was artificially kept constant at a lower level (50 mmHg) by the occluder. Although Ang II decreased PtiO2 at a PSMA of 50 mmHg, splanchnic lactate production was not observed. CONCLUSION: We demonstrate that splanchnic vasoconstriction by exogenous Ang II is dependent on arterial driving pressure, suggesting significant potentiation through autoregulatory increases in vasomotor tone. Intestinal hypoxaemia does not seem to occur during short-term infusion of Ang II in doses that significantly increases systemic arterial pressure.
  •  
7.
  • Odenstedt Hergès, Helena, et al. (författare)
  • Descending aortic blood flow and cardiac output: a clinical and experimental study of continuous oesophageal echo-Doppler flowmetry.
  • 2001
  • Ingår i: Acta anaesthesiologica Scandinavica. - 0001-5172. ; 45:2, s. 180-7
  • Tidskriftsartikel (refereegranskat)abstract
    • Several studies have demonstrated that perioperative optimisation of oxygen delivery and haemodynamics can reduce mortality and morbidity for high-risk surgical patients. To optimise cardiac output, reliable, continuous and "less invasive" methods for measuring cardiac output are urgently needed.Eight landrace pigs were studied during experimental repeated cardiac tamponade and 14 patients during liver transplantation. Aortic blood flow was measured by using transoesophageal echo-Doppler technique. A total of 91 paired measurements of aortic blood flow and cardiac output with different techniques were performed in the pigs and 124 paired measurements in the patients.Transoesophageal echo-Doppler did provide continuous real-time monitoring of the rapid and dramatic haemodynamic changes occurring during cardiac tamponade and during liver transplantation, while only intermittent information was obtained from the bolus thermodilution technique. Changes in haemodynamics were more difficult to detect with the "continual" cardiac output thermodilution technique. Changes in aortic blood flow closely followed changes in cardiac output determined by the bolus thermodilution technique both in pigs (r= 0.89) and in patients (r=0.80). In patients, aortic blood flow constituted about 70% of cardiac output determined by the bolus thermodilution technique.A combined echo-Doppler technique can be valuable for continuous monitoring of haemodynamic changes in the perioperative setting, and changes in aortic blood flow agree well with corresponding changes in cardiac output intermittently obtained by thermodilution cardiac output measurements. With the combined echo-Doppler technique a proper position of the Doppler beam is greatly facilitated by the M-mode echo visualisation of the aortic wall and aortic cross-sectional area is continuously measured.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-7 av 7

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy