SwePub
Sök i SwePub databas

  Utökad sökning

Träfflista för sökning "WFRF:(Anthony Aletras H.) srt2:(2018)"

Sökning: WFRF:(Anthony Aletras H.) > (2018)

  • Resultat 1-4 av 4
Sortera/gruppera träfflistan
   
NumreringReferensOmslagsbildHitta
1.
  • Cheimariotis, Grigorios Aris, et al. (författare)
  • Automatic lung segmentation in functional SPECT images using active shape models trained on reference lung shapes from CT
  • 2018
  • Ingår i: Annals of Nuclear Medicine. - : Springer Science and Business Media LLC. - 0914-7187 .- 1864-6433. ; 32:2, s. 94-104
  • Tidskriftsartikel (refereegranskat)abstract
    • Objective: Image segmentation is an essential step in quantifying the extent of reduced or absent lung function. The aim of this study is to develop and validate a new tool for automatic segmentation of lungs in ventilation and perfusion SPECT images and compare automatic and manual SPECT lung segmentations with reference computed tomography (CT) volumes. Methods: A total of 77 subjects (69 patients with obstructive lung disease, and 8 subjects without apparent perfusion of ventilation loss) performed low-dose CT followed by ventilation/perfusion (V/P) SPECT examination in a hybrid gamma camera system. In the training phase, lung shapes from the 57 anatomical low-dose CT images were used to construct two active shape models (right lung and left lung) which were then used for image segmentation. The algorithm was validated in 20 patients, comparing its results to reference delineation of corresponding CT images, and by comparing automatic segmentation to manual delineations in SPECT images. Results: The Dice coefficient between automatic SPECT delineations and manual SPECT delineations were 0.83 ± 0.04% for the right and 0.82 ± 0.05% for the left lung. There was statistically significant difference between reference volumes from CT and automatic delineations for the right (R = 0.53, p = 0.02) and left lung (R = 0.69, p < 0.001) in SPECT. There were similar observations when comparing reference volumes from CT and manual delineations in SPECT images, left lung (bias was − 10 ± 491, R = 0.60, p = 0.005) right lung (bias 36 ± 524 ml, R = 0.62, p = 0.004). Conclusion: Automated segmentation on SPECT images are on par with manual segmentation on SPECT images. Relative large volumetric differences between manual delineations of functional SPECT images and anatomical CT images confirms that lung segmentation of functional SPECT images is a challenging task. The current algorithm is a first step towards automatic quantification of wide range of measurements.
  •  
2.
  • Engblom, Henrik, et al. (författare)
  • Importance of standardizing timing of hematocrit measurement when using cardiovascular magnetic resonance to calculate myocardial extracellular volume (ECV) based on pre- and post-contrast T1 mapping
  • 2018
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Cardiovascular magnetic resonance (CMR) can be used to calculate myocardial extracellular volume fraction (ECV) by relating the longitudinal relaxation rate in blood and myocardium before and after contrast-injection to hematocrit (Hct) in blood. Hematocrit is known to vary with body posture, which could affect the calculations of ECV. The aim of this study was to test the hypothesis that there is a significant increase in calculated ECV values if the Hct is sampled after the CMR examination in supine position compared to when the patient arrives at the MR department. Methods: Forty-three consecutive patients including various pathologies as well as normal findings were included in the study. Venous blood samples were drawn upon arrival to the MR department and directly after the examination with the patient remaining in supine position. A Modified Look-Locker Inversion recovery (MOLLI) protocol was used to acquire mid-ventricular short-axis images before and after contrast injection from which motion-corrected T1 maps were derived and ECV was calculated. Results: Hematocrit decreased from 44.0 ± 3.7% before to 40.6 ± 4.0% after the CMR examination (p < 0.001). This resulted in a change in calculated ECV from 24.7 ± 3.8% before to 26.2 ± 4.2% after the CMR examination (p < 0.001). All patients decreased in Hct after the CMR examination compared to before except for two patients whose Hct remained the same. Conclusion: Variability in CMR-derived myocardial ECV can be reduced by standardizing the timing of Hct measurement relative to the CMR examination. Thus, a standardized acquisition of blood sample for Hct after the CMR examination, when the patient is still in supine position, would increase the precision of ECV measurements.
  •  
3.
  • Kording, Fabian, et al. (författare)
  • Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating
  • 2018
  • Ingår i: Journal of Cardiovascular Magnetic Resonance. - : Springer Science and Business Media LLC. - 1097-6647 .- 1532-429X. ; 20:1
  • Tidskriftsartikel (refereegranskat)abstract
    • Background: Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. Methods: Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. Results: Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). Conclusion: High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.
  •  
4.
  • Xanthis, Christos G., et al. (författare)
  • Simulation-based quantification of native T1 and T2 of the myocardium using a modified MOLLI scheme and the importance of Magnetization Transfer
  • 2018
  • Ingår i: Magnetic Resonance Imaging. - : Elsevier BV. - 0730-725X. ; 48, s. 96-106
  • Tidskriftsartikel (refereegranskat)abstract
    • Quantitative cardiovascular Magnetic Resonance Imaging techniques are gaining wide acceptance within the MR community due to their potential to diagnose non-localized disease, guide therapy and improve patient outcome. During the last decade, there has been an increasing interest for developing new techniques that allow for simultaneous quantification of both T1 and T2 maps of myocardium. Newer studies demonstrated that the incorporation of MRI simulations could yield similar results to conventional mapping techniques in the myocardium. However, these simulation-based quantitative MR techniques usually compare the in-vivo T1 estimates against less accurate T1 techniques, whereas they present inconsistencies between simulation studies, phantom and in-vivo measurements. Moreover, these studies do not investigate the effect of Magnetization Transfer on the myocardial T1 and T2 estimates but are usually validated on phantoms where the MT effect is small. The main aim of this study was to perform simultaneous mapping of the native T1 and T2 of the myocardium through the utilization of a modified MOLLI pulse sequence and the incorporation of advanced MR simulations through the SQUAREMR framework. A second aim of this study was to investigate the effect of MT on simulation-based quantitative MR techniques. A conventional MOLLI pulse sequence was modified so as to present combined high T2 sensitivity and low MT effect. The new technique was applied in healthy volunteers and demonstrated an improved T1 accuracy compared to the conventional MOLLI and a T2 accuracy similar to the one provided by the T2prep-bSSFP method. The effect of MT on T1 and T2 estimates was also investigated in the current study. Phantoms with an increasing MT effect as well as phantoms without an MT effect were included in this work whereas several variants of the modified-MOLLI that introduce different amounts of T2 modulation on the MR signal and induce different MT effects were applied on the phantoms. The proposed simulation-based quantitative MR technique for simultaneous T1 and T2 mapping of the myocardium does not require the incorporation of a complicated custom designed pulse sequence and does not require a complicated reconstruction workflow. Moreover, the current study demonstrates for the first time that MT plays an important role in the simulation-based quantitative MR studies and points out the necessity of incorporating the study of MT in future techniques.
  •  
Skapa referenser, mejla, bekava och länka
  • Resultat 1-4 av 4

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy